Zone Control Valves Toronto | UL/FM/ULC Floor Control Valve Assemblies for High-Rise Sprinkler Systems | Valve-Atlas

Zone Control Valves Toronto: UL/FM/ULC Listed Floor Control Valve Assemblies with Butterfly or OS&Y Gate Valve, Waterflow Switch and Drain for NFPA 13 High-Rise Sprinkler Floor Isolation

ValveAtlas supplies UL Listed, FM Approved and ULC Certified zone control valve assemblies (UVZC-100, UVZC-150, UVZC-200 and UVZC-250) with butterfly or OS&Y gate isolation valve, integrated waterflow switch (UVWF paddle), sight glass drain (UVTD test and drain) and pressure gauge package mounted on a common manifold to fire protection contractors and mechanical subs across Toronto. Full submittal for Toronto Fire Services (TFS) approval under Ontario Building Code (OBC) 3.2.5.

Technical reference for Toronto high-rise sprinkler designers and floor control valve specifiers at Pearson (YYZ), Ford Oakville, CN Tower, University of Toronto and Equinix TR1-TR2. Zone control valve assembly (ZCV) provides per-floor isolation, inspector test, drain and flow detection at each floor or zone sprinkler main per NFPA 13 Section 8.16. Single-point connection reduces on-site labor and field-labeled factory assembly.

UNIVAL UVZC product range for Toronto projects

UVZC-100 through UVZC-250 covers DN100, DN150, DN200, DN250 floor mains with UVB-G310 grooved butterfly (UL/ULC/FM) or UV0199 OS&Y gate (UL/ULC/FM) as isolation valve, UVWF paddle-type waterflow switch (UL 346/FM 1049), UVTD single-handle test and drain valve (UL 1726), bronze pressure gauges, sight glass and drain piping. Assembly ships fully piped with tamper switches pre-wired to leader terminal strip. Factory hydrostatic tested to 300 psi.

Why Toronto contractors choose ValveAtlas zone control valves

Factory-assembled single-point floor control. UVZC arrives fully piped and pressure tested. Contractor connects one inlet flange to riser and one outlet to floor sprinkler main. No field piping of test, drain, gauge or flow switch harness.

UL/FM/ULC listed components throughout. Every valve and switch in the assembly carries individual UL or FM listing. The assembly itself carries UL system listing for floor control valve application per NFPA 13 Section 8.16.1.

Tamper switches pre-wired. Butterfly integral tamper and OS&Y gate supervisory tamper switch terminated to a labeled junction box. Contractor pulls one multi-conductor to the fire alarm panel zone card.

Competitor substitution for Toronto projects

Victaulic Series 705/791 floor control valve, Potter Roemer ZCV, AGF 1000 floor control valve and Viking FCV-100 all substitute one-for-one with UVZC at matching size and isolation-valve type. Same component-level UL/FM/ULC listing. Factory submittal available for Toronto Fire Services (TFS) acceptance.

Related Toronto products

See also: Butterfly valves Toronto, Gate valves Toronto, Waterflow switches Toronto, Test and drain valves Toronto.

Contact ValveAtlas for Toronto zone control valves quotation

Email UVZC quotation requests and Victaulic/Potter Roemer/AGF/Viking substitution submittals for Toronto Fire Services (TFS) approval to info@valve-atlas.com.

Why Engineers Trust ValveAtlas for Zone Control Valves Toronto

ValveAtlas is the trusted zone control valves toronto supplier for fire protection contractors, mechanical engineers, and industrial end users across Canada, the United States, and London, UK. Every zone control valves toronto order ships with mill test certificates, UL/FM compliance letters, and dimensional drawings ready for engineer-of-record submittal. Reach the ValveAtlas team for zone control valves toronto quotations, code authority liaison, and project staging support.

Related Locations

Codes & Industry Standards

Every zone control valves toronto shipment from ValveAtlas is supported by the following code and listing references: