Locations

Service Locations — Toronto, Montréal, New York, Boston & London UK

ValveAtlas supplies UL Listed, FM Approved, and ULC certified fire protection valves, sprinklers, fire pumps, grooved couplings and HVAC mechanical room components from our Toronto headquarters to projects across Ontario, Québec, the Northeast US, and the United Kingdom. Every shipment includes mill test certificates, jurisdiction-specific approval letters, and submittal packages prepared for the local AHJ.

Select Your Region

Toronto, ON

Headquarters

Our home base — same-week delivery across the Greater Toronto Area and Ontario. Active on high-rise residential, hospital, data centre and warehouse fire protection projects.

Compliance:Ontario Building Code (OBC) 3.2.5 sprinkler protection; ULC-listed products required by Ontario Fire Code; AHJ: Toronto Fire Services. NFPA 13 / NFPA 14 standpipe systems for commercial buildings over 6 storeys.

Toronto details →

Montréal, QC

EN & FR support

Bilingual project support for Québec contractors. We coordinate French-language submittals and CSA / ULC dual-certification documentation for SIM Montréal review.

Compliance:Code de construction du Québec (CCQ); Régie du bâtiment du Québec (RBQ); AHJ: Service de sécurité incendie de Montréal (SIM). ULC listing required; French-language datasheets on request.

Montréal details →

New York, NY

FDNY · MEA

Cross-border supply for NYC commercial and high-rise projects. We pre-screen all products against NYC requirements before shipping — no surprises at AHJ review.

Compliance:NYC Construction Codes (BC §903, MC §307); FDNY Bureau of Fire Prevention review; MEA (Material Equipment Acceptance) number required for many devices; NFPA 13 / 14 / 20 / 25 reference standards.

New York details →

Boston, MA

BFD · 780 CMR

New England regional service — Massachusetts, Rhode Island, Connecticut and southern New Hampshire. Strong support for institutional and life-safety retrofits.

Compliance:Massachusetts State Building Code (780 CMR, 9th ed., based on IBC 2015 with MA amendments); 527 CMR 1.00 (Comprehensive Fire Safety Code); AHJ: Boston Fire Department; NFPA 13 sprinkler installations.

Boston details →

London, UK

LPCB · BS

UK and Greater London projects sourced through our UK partner logistics. Products are LPCB-listed and supplied with BS EN-compliant documentation packs.

Compliance:BS 9990 (non-automatic fire-fighting systems); BS 9251 (residential sprinkler systems); BS EN 12259 (sprinkler components); LPCB LPS 1014 listed sprinklers; Approved Document B (Fire Safety).

London details →

Other Regions

Project-based

Custom regional quotes for projects in other Canadian provinces, US states, or international markets. We screen each project against the local AHJ requirements before quoting.

Process:Submit project specs and AHJ requirements; we confirm product compliance and lead-times within 24 hours. Reference standards: NFPA 13/14/20/24, ASHRAE 90.1, ISO 6182.

Get a custom quote →

Code & Standards Reference by Region

Quick reference — the primary listings and authorities we ship products against, by region. Email info@valve-atlas.com with project specs for detailed compliance letters.

Region Primary Building Code Product Listing AHJ
Ontario, Canada OBC 2024 (Ont. Reg. 332/12) ULC-listed Local fire services + OFM
Québec, Canada CCQ (chap. Bâtiment) ULC + CSA RBQ + SIM Montréal
New York, USA NYC BC §903, MC §307 UL / FM + MEA # FDNY BFP
Massachusetts, USA 780 CMR + 527 CMR 1.00 UL / FM BFD + State Fire Marshal
United Kingdom Approved Doc B + BS 9251/9990 LPCB LPS 1014 / BS EN 12259 Local Fire and Rescue + Building Control

Need a Quote for a Project Outside These Cities?

Tell us the project location, type, and applicable codes. Within 24 hours we will confirm whether the products you need are listed for your jurisdiction, send compliant alternatives if not, and quote landed cost with documentation.

Request a Quote →