Butterfly Valves for Fire Protection: UL, ULC and FM Listed UNIVAL UVB-G310
ValveAtlas supplies UL Listed, ULC Listed and FM Approved UNIVAL butterfly valves for fire protection service on sprinkler risers, standpipe zones, fire pump discharge, underground water mains and zone isolation. The UNIVAL UVB-G310 grooved-end butterfly valve with integrated supervisory tamper switch is the workhorse sprinkler-zone isolation valve on projects from Toronto high-rise to London data centre to New York commercial office.
This page is the technical reference for specifying engineers, EPC project firms, construction firms and mechanical subcontractors selecting butterfly valves on fire protection systems governed by NFPA 13, NFPA 20, NFPA 24, BS EN 12845, Approved Document B, Code du Québec Chapitre Bâtiment and the NYC Mechanical Code.
UNIVAL butterfly valve range stocked at ValveAtlas
| UNIVAL SKU | Type | End connection | Pressure class | Listings | Sizes |
|---|---|---|---|---|---|
| UVB-G310 | Grooved butterfly, gear operator, tamper switch | AWWA/NPS grooved | 300 psi CWP | UL, ULC, FM | 2″ to 12″ |
| UVB-W310 | Wafer butterfly, gear operator, tamper switch | Wafer (pin-between-flange) | 300 psi CWP | UL, ULC, FM | 2″ to 12″ |
| UVB-L310 | Lug butterfly, gear operator, tamper switch | Lug (flanged-end service) | 300 psi CWP | UL, ULC, FM | 2″ to 12″ |
Where butterfly valves are used in fire protection
Sprinkler zone isolation. NFPA 13 Chapter 16 and BS EN 12845 Section 15 require a listed indicating valve upstream of every sprinkler zone so the zone can be isolated for maintenance without shutting down the entire system. The UNIVAL UVB-G310 with integrated tamper switch satisfies both the indicating valve requirement (open/close visible at the gear operator) and the supervision requirement (tamper switch wired to the fire alarm control panel per NFPA 72).
Fire pump suction and discharge isolation. NFPA 20 Section 4.16 and FM Global Data Sheet 3-7 require listed isolation valves on the suction and discharge sides of every fire pump. For horizontal split case and vertical turbine pumps discharging at 175 to 250 psi, the UVB-G310 300 psi CWP rating covers the service. For high-rise fire pumps discharging at 500 psi (tall-building standpipe pressure zones), ValveAtlas coordinates the 500 psi-class butterfly valve variant on special order.
Standpipe zone control. NFPA 14 Chapter 6 and BS 9990 Section 7 require isolation on each standpipe zone. The UVB-G310 is the standard selection on Class I, Class II and Class III standpipe zones across commercial high-rise and residential high-rise.
Underground water main tie-ins. NFPA 24 and AWWA M-class water main service use listed butterfly valves at the property-line tap, at the sprinkler riser base and at isolation points along the underground loop. UVB-G310 covers the service down to 2″ and up to 12″ in grooved-end configuration.
Listings and code acceptance
UL 1091 and UL 262. UNIVAL UVB-G310 carries UL 1091 (butterfly valves for fire protection service) and UL 262 (gate valves for fire protection) equivalent scope listing. The UL certificate is issued to UNIVAL manufacturer and is provided in the ValveAtlas submittal package.
ULC listing for Canadian projects. The ULC listing covers the same SKU and is recognized under CAN/ULC-S543 for listing of sprinkler components. Quebec RBQ projects, Ontario projects under OBC Part 3 and Canadian projects referencing NFPA 13 Canadian edition accept the ULC certificate.
FM Approval. FM Approvals Class 1112 (indicating valves for fire protection) certifies UVB-G310 for FM-insured properties under FM Global Data Sheet 2-0. Insurance surveyors at FM Global, RSA, Aviva, Zurich, Allianz, AXA Commercial, Chubb, AIG, Travelers, Intact and Aviva Canada accept the FM certificate on their insured properties.
LPCB and UK acceptance. UK projects under BS EN 12845 and the LPC Rules accept the UL/FM listing where the UL scope is equivalent to LPCB listing under LPS 1041 for indicating valves. Verify the UL scope equivalence with the insurance surveyor for LPCB-specific specifications.
Substitution matrix from Victaulic, Nibco, Keystone and Milwaukee
Project specifications routinely call out Victaulic, Nibco, Keystone or Milwaukee butterfly valves by SKU. UNIVAL substitutes as follows.
Victaulic Series 705 grooved butterfly. Substitute UNIVAL UVB-G310 grooved butterfly with tamper. Same 300 psi CWP rating, same UL/ULC/FM listing scope, same gear operator interface. See the UNIVAL vs Victaulic comparison.
Nibco GD-4765 and GD-4865 grooved butterfly. Substitute UVB-G310. UL/ULC/FM listed, 300 psi CWP, tamper integrated.
Keystone K-LOK Figure 362 wafer butterfly. Substitute UVB-W310 wafer butterfly. UL/ULC/FM listed, 300 psi CWP.
Milwaukee MW-333 and MW-334 butterfly. Substitute UVB-W310 (wafer) or UVB-L310 (lug). 300 psi CWP with UL/ULC/FM listing.
Regional stock and delivery across the ValveAtlas network
Toronto. UVB-G310 2″ to 8″ in stock at Toronto HQ for same-day shipment across Ontario. See Fire Protection Toronto.
Montreal. Next-day truck freight from Toronto covers Montreal, Laval, Longueuil and the wider Quebec market. RBQ submittals include ULC certificate on UVB-G310. See Fire Protection Montreal.
New York. 2-day truck freight from Toronto covers NYC, Westchester, Hudson Valley and Long Island. NYC DOB and FDNY accept the UL certificate on UVB-G310. See Fire Protection New York.
Boston. 2-day truck freight from Toronto covers Boston, Cambridge, the North Shore, South Shore and MetroWest. 780 CMR and BFD acceptance under UL listing. See Fire Protection Boston.
London UK. UK partner warehouse stocks UVB-G310 for 48-hour delivery to central London. Toronto HQ ships non-stock sizes on 5 to 7 day air freight via Heathrow. See Fire Protection London.
Related products for complete sprinkler zone protection
UVB-G310 butterfly valves install on a zone that also includes alarm valve, gate valve isolation, grooved couplings and test-and-drain station. ValveAtlas stocks the complete scope.
Alarm valves. UVW-1511-300 wet alarm valve, UVD-2511-300 dry pipe valve, UVPR-5311-300 pre-action valve, UVPPD deluge valve. See Wet Alarm Valves.
Gate valves. UV0199 OS&Y gate flanged, UV0299 NRS gate. Listed UL/ULC/FM for fire protection indicating valve service upstream of the butterfly valve in branch configuration.
Grooved couplings and fittings. UV11 rigid 300 psi CWP, UV14 flexible 300 psi CWP, UV15 heavy-duty rigid 500 psi CWP, UV16 heavy-duty flexible 500 psi CWP. See Coupling Fittings pillar page.
Post indicator valves. UV0800-IP post indicator valve for private water main isolation at the property line on campus and industrial sites.
Test and drain. Listed 2-way test and drain stations at the sprinkler zone inspector’s test. See Test and Drain Valves.
Frequently asked questions
What is the difference between a grooved, wafer and lug butterfly valve? Grooved (UVB-G310) connects to grooved-end pipe via the UV11 or UV14 coupling and is the default on sprinkler risers. Wafer (UVB-W310) installs pin-between-flange between two flanges and is used where flanged pipe is already in service. Lug (UVB-L310) has threaded lugs allowing downstream removal without draining upstream pressure; used on fire pump discharge headers and at zone control where one side of the valve may need to be removed while the other stays pressurized.
Is the tamper switch integrated or separate? UVB-G310, UVB-W310 and UVB-L310 ship with factory-integrated SPDT tamper switch terminated at a junction box on the gear operator housing. The switch monitors valve position; closure of the valve triggers a supervisory signal at the fire alarm control panel per NFPA 72 Section 17.16 and BS EN 12845 Section 20.
What is the minimum and maximum size? UVB-G310 ranges 2″ through 12″ in grooved-end configuration covering standard sprinkler zone service. Larger sizes (14″, 16″, 18″, 20″, 24″) are available on 4 to 6 week special order for fire pump discharge mains and underground water main isolation.
Is UVB-G310 accepted on high-rise fire pump discharge at 500 psi? Standard UVB-G310 is rated 300 psi CWP. For fire pump discharge operating at 500 psi on tall high-rise buildings, ValveAtlas coordinates the 500 psi-class heavy-duty butterfly valve variant. Specify the pressure class on the purchase order and ValveAtlas will confirm stock position or factory lead time.
What temperature rating does UVB-G310 carry? Standard operating temperature is -10°C to +110°C (14°F to 230°F). Below -10°C, coordinate with ValveAtlas for low-temperature elastomer seat options. For hot-water fire protection service on foam systems above 110°C, coordinate the EPDM high-temp or PTFE seat variant.
Contact ValveAtlas for a butterfly valve quotation
For butterfly valve quotations, submittal packages substituting UNIVAL for Victaulic, Nibco, Keystone or Milwaukee specifications on Toronto, Montreal, New York, Boston or London projects, email the project specification and drawings to burakpadr@gmail.com or use the contact form on our website. Standard turnaround is 48 hours from receipt of the project specification.
For the complete UNIVAL cross-reference to Victaulic, Nibco, Keystone and Milwaukee SKUs, see the UNIVAL Cross-Reference chart.
Why Engineers Trust ValveAtlas for Butterfly Valves Fire Protection
ValveAtlas is the trusted butterfly valves fire protection supplier for fire protection contractors, mechanical engineers, and industrial end users across Canada, the United States, and London, UK. Every butterfly valves fire protection order ships with mill test certificates, UL/FM compliance letters, and dimensional drawings ready for engineer-of-record submittal. Reach the ValveAtlas team for butterfly valves fire protection quotations, code authority liaison, and project staging support.
Related Locations
- Grooved Couplings and Fittings in Toronto | UL/ULC/FM Listed
- Vannes a Coin Montreal | UL 262/FM 1120/ULC NFPA 13 | ValveAtlas
- HVAC Check Valves Boston | Swing, Dual-Plate and Silent | ValveAtlas
- Post Indicator Valves New York: UL 789/FM 1110 Listed PIV and PIVA with FDNY-Accepted Tamper Supervision for NYC Supertall and Hospital Fire Mains
Codes & Industry Standards
Every butterfly valves fire protection shipment from ValveAtlas is supported by the following code and listing references: