Waterflow Switches Toronto: UL 346 Listed and FM 1049 Approved Vane-Type Sprinkler Waterflow Detectors for NFPA 13 Alarm Initiating Devices on Wet, Dry-Pipe, Pre-Action and Deluge Systems
ValveAtlas supplies UL 346 Listed and FM 1049 Approved vane-type waterflow switches (UVWF-100, UVWF-150, UVWF-200, UVWF-250, UVWF-300, UVWF-400 and UVWF-600) in sizes DN25 through DN150 (1″ through 6″) with paddle sensor, pneumatic retard, two sets of SPDT contacts and tamper-resistant enclosure to fire protection contractors and mechanical subs across Toronto. UL 346 listing with no TSE-only references. Full submittal package for Toronto Fire Services (TFS) approval under Ontario Building Code (OBC) 3.2.5.
This is the technical reference for Toronto fire alarm designers, sprinkler contractors and system integrators selecting waterflow detection for Pearson (YYZ), Ford Oakville, CN Tower, University of Toronto and Equinix TR1-TR2. UVWF paddle mounts on tee saddle at main or floor control riser. Wet pipe SPDT alarm initiation with 0-90 second adjustable retard. Dry pipe, pre-action and deluge applications use pressure-type switches (see PS-10-1 series separately).
UNIVAL UVWF waterflow switch product range
UVWF-100 through UVWF-600 covers DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN150 pipe sizes with matching paddle sensor for 1″ to 6″ sprinkler main. Each unit has two SPDT contacts (alarm + auxiliary), pneumatic retard timer adjustable 0-90 seconds for surge protection, and UL-listed weather-resistant steel enclosure with cover tamper switch option. NEMA 4X kit available for outdoor installation.
Why Toronto contractors choose ValveAtlas waterflow switches
UL 346 and FM 1049 dual listing. UL 346 (Waterflow Indicators for Fire Protective Signaling Systems) and FM 1049 (Waterflow Detectors). Every UVWF carries both listings with no TSE-only parts.
Pneumatic retard 0-90 seconds adjustable. NFPA 13 8.17.2 recommended retard prevents surge-related false alarms. Field-adjustable from closed-cell diaphragm, no batteries required.
Two sets of SPDT contacts. Primary contact for alarm panel, secondary for local bell or building management system. 10A rating at 125VAC.
Competitor substitution for Toronto projects
Potter VSR-S/VSR-F, System Sensor WFD, Viking VSR and Notifier VSR-F series all substitute one-for-one with UVWF at matching pipe size and contact configuration. Same UL 346 and FM 1049 listing. Factory submittal package for Toronto Fire Services (TFS) approval.
Related Toronto fire protection products
See also: Fire sprinklers Toronto, Wet alarm valves Toronto, Dry pipe valves Toronto, Check valves Toronto.
Contact ValveAtlas for Toronto waterflow switches quotation
Email UVWF quotation requests and Potter/System Sensor/Viking substitution submittals for Toronto Fire Services (TFS) approval to info@valve-atlas.com.
Why Engineers Trust ValveAtlas for Waterflow Switches Toronto
ValveAtlas is the trusted waterflow switches toronto supplier for fire protection contractors, mechanical engineers, and industrial end users across Canada, the United States, and London, UK. Every waterflow switches toronto order ships with mill test certificates, UL/FM compliance letters, and dimensional drawings ready for engineer-of-record submittal. Reach the ValveAtlas team for waterflow switches toronto quotations, code authority liaison, and project staging support.
Related Locations
- Post Indicator Valves New York: UL 789/FM 1110 Listed PIV and PIVA with FDNY-Accepted Tamper Supervision for NYC Supertall and Hospital Fire Mains
- HVAC Flanged Ball Valves Boston | Monoblock, Full-Port, Stainless | ValveAtlas
- Wet Alarm Valves Montreal | UL and FM Retard Chamber Trim RBQ SIM French Docs | ValveAtlas
Codes & Industry Standards
Every waterflow switches toronto shipment from ValveAtlas is supported by the following code and listing references:
