Check Valves Toronto: UL 312 Listed and FM 1210 Approved Silent-Closure, Swing Check and Spring-Loaded Check Valves for Ontario Building Code 3.2.5, NFPA 13 Section 16.8 and ULC/ORD-C312 Fire Pump Discharge, Backflow Prevention and Sprinkler Water Supply
ValveAtlas supplies UL 312 Listed, FM Class 1210 Approved and UL 312/FM 1210 approved check valves including silent-closure non-slam, swing check, spring-loaded wafer, double-disc and grooved-end configurations to fire protection contractors, mechanical consultants and general contractors across Toronto, Mississauga, Brampton, Hamilton, Vaughan, Markham, Richmond Hill, Oshawa, Kitchener-Waterloo and London ON. Metro delivery, factory-coated ductile-iron bodies, stainless steel springs and EPDM resilient seats for -30 C Ontario winter service and OBC 3.2.5 submittal packages for TFS.
This page is the technical reference for Toronto specifying engineers, sprinkler contractors, mechanical installers and civil underground contractors selecting check valve packages for Pearson International (YYZ), Billy Bishop (YTZ) and Hamilton International (YHM) fire mains, UHN (Toronto General, Toronto Western, Princess Margaret), SickKids, Mount Sinai, Sunnybrook, St. Michael’s and William Osler campus loops, University of Toronto, Ryerson (TMU), York University, McMaster, Waterloo and Western campuses, Equinix TR1/TR2/TR3, Cologix TOR1, Q9 151 Front and Digital Realty data centers and any NFPA 13 Section 16.8 or NFPA 20 Chapter 4.16 fire pump discharge and backflow prevention application, governed by Ontario Building Code 3.2.5 and ULC/ORD-C312, NFPA 13 Section 16.8, NFPA 20 Chapter 4.16.
Check valve range for Toronto fire protection projects
| Type | UNIVAL SKU | Size | Max working pressure | Listings | Typical Toronto application |
|---|---|---|---|---|---|
| Silent-closure non-slam | UVC-NR-4F | 4 inch / DN100 flanged | 175 psi | UL 312, FM 1210 | Fire pump discharge per NFPA 20 Chapter 4.16, water hammer control |
| Silent-closure non-slam | UVC-NR-6F | 6 inch / DN150 flanged | 250 psi | UL 312, FM 1210 | Fire pump discharge and sprinkler incoming main |
| Silent-closure non-slam | UVC-NR-8F | 8 inch / DN200 flanged | 250 psi | UL 312, FM 1210 | Horizontal split-case fire pump discharge |
| Swing check | UVC-SW-6F | 6 inch / DN150 flanged | 175 psi | UL 312, FM 1210 | Sprinkler water supply, standpipe isolation check |
| Swing check with lever and weight | UVC-SW-8F-LW | 8 inch / DN200 flanged | 175 psi | UL 312, FM 1210 | Horizontal fire service main with ball drip |
| Spring-loaded wafer | UVC-WAFER-4 | 4 inch wafer | 300 psi | UL 312, FM 1210 | Compact installation between flanges, grooved piping |
| Double-disc wafer | UVC-DBL-6 | 6 inch wafer | 300 psi | UL 312, FM 1210 | Low-headloss high-flow fire pump discharge |
| High-pressure silent | UVC-NR-6F-HP | 6 inch flanged | 300 psi | UL 312, FM 1210 | High-rise standpipe lower zone, fire pump high-pressure |
| Grooved-end silent | UVC-NR-6G | 6 inch grooved | 300 psi | UL 312, FM 1210 | Grooved fire pump discharge, hospital and data center |
Why Toronto contractors choose ValveAtlas check valves
UL 312 and FM 1210 dual listing for TFS acceptance. Every UNIVAL check valve is UL 312 Listed (check valves for fire-protection service) and FM Class 1210 Approved. TFS accepts listed check valves with factory submittal, OBC 3.2.5 compliance letter and NFPA 13 Section 16.8 sprinkler water supply documentation.
Silent-closure non-slam for fire pump discharge. NFPA 20 Chapter 4.16 requires listed check valve on fire pump discharge. UVC-NR silent-closure design uses spring-assisted center-guided disc to close before flow reversal, eliminating water hammer, pipe shock and column separation damage that plagues swing check valves on pump shutdown. Critical for Toronto fire pump rooms with long discharge runs.
Swing check for sprinkler incoming main. UVC-SW-4F through UVC-SW-10F flanged swing check valves with bronze or stainless disc, ductile iron body and renewable resilient seat. UL 312 Listed for sprinkler water supply, standpipe isolation check and hose valve riser check per NFPA 13 Section 16.8.
Spring-loaded wafer for compact installation. UVC-WAFER-4 through UVC-WAFER-8 wafer-body spring-loaded check valves installed between ANSI Class 125/250 flanges with no external bolting. Ideal for Toronto mechanical rooms with limited space between pump discharge flange and downstream gate valve.
Double-disc for low-headloss high-flow. UVC-DBL-4 through UVC-DBL-10 double-disc (duo-check) wafer valves with spring-loaded twin discs provide lowest headloss and fastest closure for high-flow fire pump discharge service. UL 312 Listed and FM Class 1210 Approved equivalent to APCO CVS-6000 and Val-Matic Dual Disc.
Ductile iron body with fusion-bonded epoxy. UVC bodies are ductile iron ASTM A536 Grade 65-45-12 with factory-applied fusion-bonded epoxy coating per AWWA C550, rated for indoor dry-sidewall mount and wet pipe service. Stainless steel spring and shaft, EPDM or buna-N resilient seat and bronze seating surface rated for 175 psi / 250 psi / 300 psi working pressure.
Direct substitution for Mueller, Clow, Kennedy, M&H and AVK. UNIVAL UVC-NR, UVC-SW and UVC-WAFER are UL 312/FM 1210 listed equivalent to Mueller A-2061 and A-2062, Clow F-1100, Kennedy 1500, M&H Style 259 and AVK Series 53/35. TFS accepts listed equivalent substitutions with engineer-of-record approval and factory submittal package.
Code and listing acceptance for Toronto
Ontario Building Code 3.2.5. Ontario Building Code 3.2.5 references NFPA 13 and ULC/ORD-C312, NFPA 13 Section 16.8, NFPA 20 Chapter 4.16 for fire sprinkler and fire pump check valves. Check valve selection must satisfy Section 903.3.5 sprinkler water supply and Section 913 fire pump installation. UVC UNIVAL ships OBC 3.2.5 compliant.
NFPA 13 Section 16.8 sprinkler water supply check. NFPA 13 Section 16.8 requires listed check valve on sprinkler water supply connection to prevent backflow into public water main. UVC-SW and UVC-NR series satisfy this requirement. Section 16.8.2 specifies check valve plus listed indicating control valve configuration.
NFPA 20 Chapter 4.16 fire pump discharge. NFPA 20 Chapter 4.16 requires listed check valve on fire pump discharge between pump and discharge gate valve. Silent-closure non-slam check preferred for water hammer control. UVC-NR-4F through UVC-NR-10F satisfy NFPA 20 discharge check valve requirement in all Toronto fire pump room installations.
Backflow prevention for potable water protection. Where sprinkler system connects to potable water main, double check valve assembly or reduced-pressure zone (RPZ) backflow preventer required per local water authority. UVC check valve series provides base check valve; RPZ/DCVA assemblies available as separate line item.
TFS acceptance. Toronto Fire Services (TFS) and Ontario Ministry of the Solicitor General Office of the Fire Marshal inspection references Ontario Building Code 3.2.5, ULC/ORD-C312, NFPA 13 Section 16.8, NFPA 20 Chapter 4.16 and manufacturer listing. Factory submittal with UL/FM/ULC certificates, functional test per NFPA 25 Chapter 13 and hydrostatic test per AWWA C508 required for sign-off.
Mueller, Clow, Kennedy, M&H and AVK substitution for Toronto projects
Mueller A-2061 and A-2062 swing check. Substitute UVC-SW-4F, UVC-SW-6F or UVC-SW-8F at matching size and flange drilling (ANSI B16.1 Class 125/250). Same UL 312/FM 1210 listing, ductile iron body with fusion-bonded epoxy, bronze or stainless disc. Toronto standard brand substitution with factory submittal package.
Clow F-1100 flanged swing check. Substitute UVC-SW-6F or UVC-SW-8F at matching duty. Same swing check construction with ductile iron body, renewable resilient seat and AWWA C508 compliance for buried or indoor fire service.
Kennedy 1500 silent check. Substitute UVC-NR-4F, UVC-NR-6F or UVC-NR-8F silent-closure non-slam at matching size and pressure rating. Same spring-assisted center-guided design for fire pump discharge water hammer control.
M&H Style 259 swing check. Substitute UVC-SW-6F or UVC-SW-8F at matching pressure class. Same AWWA C508 compliance and bronze or stainless disc for fire service main check.
APCO CVS-6000 double-disc. Substitute UVC-DBL-4, UVC-DBL-6 or UVC-DBL-8 at matching wafer dimension. Same low-headloss double-disc (duo-check) construction with UL 312/FM 1210 listing.
AVK Series 53/35 resilient seated check. Substitute UVC-SW or UVC-NR at matching configuration. Matching EPDM resilient seat, ductile iron body and UL/FM listing.
Installation scenarios for Toronto check valves
Pearson International (YYZ), Billy Bishop (YTZ) and Hamilton International (YHM) fire pump rooms and fire mains. Airport fire pump discharge with UVC-NR-8F silent-closure on horizontal split-case pumps, UVC-NR-6F on end-suction pumps and UVC-SW-8F-LW on fire service main with ball drip. Water hammer protection critical for long airside piping runs to terminals and cargo ramps.
UHN (Toronto General, Toronto Western, Princess Margaret), SickKids, Mount Sinai, Sunnybrook, St. Michael’s and William Osler campus fire pump and sprinkler. Toronto hospital campus fire pump rooms with UVC-NR-6F and UVC-NR-8F silent-closure discharge check, UVC-SW-6F sprinkler incoming main check and UVC-WAFER-4 compact installation at pre-action panel bypass. Redundant fire pump rooms per NFPA 20 Chapter 11.
University of Toronto, Ryerson (TMU), York University, McMaster, Waterloo and Western campus standpipe and sprinkler. University building standpipe check valves with UVC-SW-6F and UVC-SW-8F at incoming main, UVC-NR-4F silent-closure at local fire pump discharge for high-rise research buildings and lab facilities. TFS acceptance with factory submittal.
Equinix TR1/TR2/TR3, Cologix TOR1, Q9 151 Front and Digital Realty data center fire pump and pre-action. Data center fire pump discharge with UVC-NR-6F silent-closure non-slam for zero water hammer on pump trip, UVC-DBL-6 double-disc for lowest headloss on high-flow systems and UVC-WAFER-4 at pre-action riser manifold. Tamper-supervised indicating valves upstream and downstream.
High-rise standpipe and sprinkler. Toronto high-rise standpipe zone check valves with UVC-NR-6F-HP 300 psi at lower zones and UVC-SW-6F 175 psi at upper zones. NFPA 14 Chapter 6 compliant with backflow prevention on interconnections between pressure zones.
Related products for complete Toronto fire protection valve package
Gate valves. UVG-OSY OS&Y rising stem gate valves upstream and downstream of check valve per NFPA 20. See Gate Valves Toronto.
Butterfly valves. UVB-G310 grooved butterfly with integral tamper as indicating control valve alternative. See Butterfly Valves Toronto.
Fire pumps. UVFP-HSC, UVFP-ES and UVFP-VIL fire pumps with silent-closure check valve discharge per NFPA 20. See Fire Pumps Toronto.
Hydrants. UVH-5BR wet-barrel and UVH-3DRY dry-barrel hydrants with integral bronze check disc and drain. See Hydrants Toronto.
Frequently asked questions (Toronto)
Is UNIVAL accepted by TFS? Yes. UNIVAL check valves are UL 312 Listed and FM 1210 Approved. TFS accepts listed check valves with factory submittal, OBC 3.2.5 compliance letter and NFPA 13 Section 16.8 documentation.
Silent-closure vs swing check on fire pump discharge? NFPA 20 accepts both listed silent-closure and swing check on fire pump discharge. Silent-closure UVC-NR eliminates slam and water hammer on pump trip; swing check UVC-SW is lower cost and preferred on low-velocity sprinkler incoming mains. For Toronto fire pump rooms with long discharge piping or variable-speed drive (VSD), silent-closure is strongly recommended.
What causes check valve slam? Swing check valves close when flow reverses. On fast pump shutdown, flow reverses rapidly; disc slams shut, generating water hammer shock wave that can rupture piping. Silent-closure UVC-NR uses spring and center-guide to close disc before flow reverses, eliminating slam.
Do I need check valve upstream and downstream of fire pump? NFPA 20 Chapter 4.16 requires check valve on discharge side only. Suction side has listed OS&Y gate valve (UVG-OSY). Check valve on suction is not permitted; suction must be flooded with positive pressure per NFPA 20.
Spring-loaded wafer vs flanged swing check? Wafer UVC-WAFER-4 and UVC-DBL-4 install between flanges with no external bolting, ideal for tight spaces. Flanged swing UVC-SW-6F has full flange connections with standard face-to-face dimensions. Choose wafer for compact pump rooms; flanged for standard service.
What is the delivery time to Toronto? Stock UVC-NR-4F, UVC-NR-6F and UVC-SW-6F ship 1 to 2 weeks. UVC-WAFER and UVC-DBL wafer stock 2 to 3 weeks. UVC-NR-HP 300 psi high-pressure factory-built ships 3 to 4 weeks. Metro freight from Toronto HQ 2 to 3 business days.
How do I substitute Mueller, Clow, Kennedy, M&H and AVK on a Toronto project? Submit substitution letter with UNIVAL UL 312/FM 1210 certificates, factory submittal drawing and NFPA 13 Section 16.8 compliance. Engineer-of-record approval follows; TFS accepts listed equivalent substitutions.
Contact ValveAtlas for Toronto check valve quotation
For check valve quotations, Mueller A-2061 and A-2062, Clow F-1100, Kennedy 1500, M&H Style 259 and AVK Series 53/35 substitution submittals for TFS approval, or NFPA 13/14/20 check valve packages with silent-closure non-slam protection for Pearson International (YYZ), Billy Bishop (YTZ) and Hamilton International (YHM) airside, Toronto hospital campus, university campus, data center or high-rise standpipe projects, email the project mechanical drawings, pipe size, pressure class and fire pump curve to burakpadr@gmail.com or use the contact form. Same-day response on Toronto urgent orders.
Why Engineers Trust ValveAtlas for Check Valves Toronto
ValveAtlas is the trusted check valves toronto supplier for fire protection contractors, mechanical engineers, and industrial end users across Canada, the United States, and London, UK. Every check valves toronto order ships with mill test certificates, UL/FM compliance letters, and dimensional drawings ready for engineer-of-record submittal. Reach the ValveAtlas team for check valves toronto quotations, code authority liaison, and project staging support.
Related Locations
- Steel Pipes Boston | UL/FM Schedule 10 and Schedule 40 Sprinkler Pipe BFD | ValveAtlas
- Angle Hose Valves New York | UL 668/FM 1210/NYC BC | ValveAtlas
- Grooved Ball Valves Montreal | UL/FM Grooved-End Brass Ball Valves for Fire Protection | ValveAtlas
Codes & Industry Standards
Every check valves toronto shipment from ValveAtlas is supported by the following code and listing references: