Angle Hose Valves and Landing Valves London: UL 668 Listed, FM 1210 Approved Class I/II/III Standpipe Hose Valves for NFPA 14 Section 5.4 Compliant Installations
ValveAtlas supplies UL Listed, FM Approved and LPCB Listed angle hose valves, pressure-reducing landing valves and Class I/II/III standpipe hose connections (UVLV-ANG-1.5, UVLV-ANG-2.5, UVLV-PRV-1.5, UVLV-PRV-2.5, UVLV-SWIVEL, UVLV-AUTO, UVLV-CAB and UVLV-BS-2.5) with red brass or forged bronze body, NH or BS 336 instantaneous coupling, hand-wheel operator and break-off cap chain to fire protection contractors and mechanical subs across London. Every UNIVAL UV- line item carries UL or FM listing at minimum. Full submittal package for London Fire Brigade (LFB) approval.
This is the technical reference for London specifying engineers selecting angle hose valves packages for Heathrow (LHR), Gatwick (LGW), The Shard, Canary Wharf and Imperial College London, governed by Approved Document B and BS 9990. Stock UVLV-ANG-1.5 and UVLV-ANG-2.5 with standard NH thread ship 2 to 3 weeks.
UNIVAL UVLV product range for London projects
UVLV-ANG-1.5 is a 1.5″ angle hose valve with UL 668 listing for fire cabinet Class II occupant-use hose stations. UVLV-ANG-2.5 is the 2.5″ fire-service-use variant with UL 668 and FM 1210 dual listing for Class I/III standpipe outlets. UVLV-PRV-1.5 and UVLV-PRV-2.5 are pressure-reducing landing valves with field-adjustable 25-175 psi outlet pressure, UL 668 and FM 1210 listed with UL 1468 pressure-regulating valve approval. UVLV-SWIVEL is a swivel 2.5″ angle valve for roof manifold and apparatus hose angle flexibility. UVLV-AUTO includes automatic drip drain for exterior exposed outlets. UVLV-BS-2.5 carries LPCB LPS 1054 and BS 5041-1 listing for UK dry riser per BS 5306-1.
Why London contractors choose ValveAtlas angle hose valves
UL 668 and FM 1210 dual listing for AHJ acceptance. Every UNIVAL UVLV carries UL 668 and FM 1210 listing with forged bronze or red brass body. Pressure-reducing variants are additionally listed under UL 1468 and FM 1210.
Pressure-reducing landing valves per NFPA 14 Section 7.2.3. UVLV-PRV-1.5 and UVLV-PRV-2.5 are field-adjustable, factory-set to design pressure per riser schedule.
Red brass or forged bronze body with break-off cap chain. UVLV bodies are cast red brass (ASTM B584) or forged bronze (ASTM B283) standard. Each valve ships with a matching cap on a break-away chain per NFPA 14 6.4.5.
Competitor substitution for London angle hose valves projects
Potter Roemer Fig 4065, Croker 6000 series, Guardian 2500 PRV, Elkhart Brass and Giacomini angle landing valves all substitute one-for-one with matching UVLV SKUs at identical inlet/outlet configuration and UL 668/FM 1210/UL 1468 listing. Factory submittal package available for London Fire Brigade (LFB) approval.
Related London fire protection products
See also: Fire pumps London, FDC London, Check valves London, Gate valves London, Fire hydrants London.
Contact ValveAtlas for London angle hose valves quotation
For angle hose valves quotations and substitution submittals for London Fire Brigade (LFB) approval, email project details to info@valve-atlas.com. Same-day response on urgent orders.
