Fire Pumps Montreal: UL Listed and UL Compliant NFPA 20 Horizontal Split-Case, Vertical Inline and End-Suction Fire Pumps for Quebec High-Rise and Commercial Projects
ValveAtlas supplies UL Listed and CAN/UL-S001 compliant fire pumps, diesel engine drivers, electric motor drivers, jockey pumps, fire pump controllers and complete NFPA 20 fire pump skid packages to fire protection contractors, mechanical engineers and general contractors across Montreal, Laval, Longueuil, Quebec City, Gatineau and Sherbrooke. Toronto HQ warehouse, factory-assembled skid packages, French-language submittals and NFPA 20 / CNB / RBQ / SIM compliance documentation.
This page is the technical reference for Quebec specifying engineers, mechanical contractors and sprinkler installers selecting fire pump packages for standpipe (colonne montante), sprinkler (gicleurs) and combined systems governed by Code de construction du Quebec, NFPA 20, NFPA 13, NFPA 14, NFPA 25, UL 448 and CAN/UL-S001.
Gamme de pompes incendie pour projets Montreal
| Type | UNIVAL SKU | Debit (GPM) | Pression nette (psi) | Homologations | Entrainement | Application Quebec typique |
|---|---|---|---|---|---|---|
| Pompe horizontale a corps divise (HSC) | UVFP-HSC | 500 to 5000 | 40 to 200 | UL 448, FM 1311, UL | Electrique, diesel | Tour residentielle et commerciale Montreal |
| Pompe verticale en ligne | UVFP-VIL | 100 to 1500 | 40 to 150 | UL 448, FM 1311, UL | Electrique | Salle mecanique a espace restreint Quebec |
| Pompe a aspiration axiale | UVFP-ES | 250 to 2000 | 40 to 175 | UL 448, FM 1311, UL | Electrique, diesel | Gicleurs risque leger et risque ordinaire Quebec |
| Pompe turbine verticale | UVFP-VT | 250 to 5000 | 40 to 250 | UL 448, FM 1311, UL | Electrique, diesel (renvoi d’angle) | Aspiration sous-sol et reservoirs eau brute |
| Pompe jockey | UVFP-JP | 5 to 50 | 10 psi au-dessus pompe principale | UL Listed | Electrique (TEFC) | Maintien de pression tout ensemble Quebec |
| Ensemble skid assemble en usine | UVFP-SKID | Toutes capacites | Toutes pressions | UL, FM, UL | Electrique, diesel, combine | Installation plug-and-play tour Montreal |
Why Quebec contractors choose ValveAtlas fire pumps
UL dual listing. Every UNIVAL fire pump is UL 448 Listed and CAN/UL-S001 compliant, meeting RBQ (Regie du batiment du Quebec) listed product requirements and SIM (Service de securite incendie de Montreal) acceptance criteria. Factory performance curve and French-language certification letters provided.
French-language documentation. ValveAtlas provides French-language factory performance curve (courbe de performance), NFPA 20 submittal package, RBQ compliance letter, and installation and maintenance manual (manuel d’installation et d’entretien) per Loi 101 requirements for Quebec submittals.
NFPA 20 factory-assembled skids. Complete fire pump skids per NFPA 20 Chapter 4, including main pump, jockey pump, suction and discharge manifold, casing relief valve, main relief valve, air release, test header, pressure gauges, flow meter loop, driver and UL Listed controller. Plug-and-play delivery to Quebec mechanical room.
Diesel and electric driver options. Clarke John Deere, Clarke Cummins and Iveco FPT diesel engine drivers; Eaton, Toshiba and WEG electric motor drivers. UL Listed fire pump controllers from Eaton, Metron and Firetrol matched to driver selection. All drivers CSA certified for Quebec electrical code compliance.
Direct substitution for Patterson, Aurora, Fairbanks Nijhuis and Armstrong. UNIVAL fire pumps are UL/FM/UL listed equivalent. SIM and RBQ accept listed equivalent substitutions with engineer-of-record approval.
Code and listing acceptance for Quebec
Code de construction du Quebec Chapitre I Batiment. CCQ adopts CNB 2015 which references NFPA 20 for fire pump installation. NFPA 20 requires UL/FM/UL listed fire pumps, drivers and controllers. UNIVAL pumps meet all NFPA 20 Chapter 4 through Chapter 12 requirements.
NFPA 20 installation des pompes incendie. Chapitre 4 (exigences generales), Chapitre 5 (pompes), Chapitre 6 (raccords et tuyauterie), Chapitre 9 (entrainement electrique), Chapitre 10 (commandes), Chapitre 11 (entrainement diesel), Chapitre 14 (essais de reception) govern Quebec fire pump installation.
RBQ licence et SIM acceptance. RBQ licence 5332 sprinkler contractors and RBQ licence 5332-1 mechanical contractors use UNIVAL skids for SIM final inspection and RBQ annual certification. French-language factory performance curve accepted at SIM witness testing.
CSDM, CSMB, McGill, Concordia, UQAM. Quebec public sector projects standardize on UL/FM/UL listed fire pump skids with French-language submittal package. Bid package acceptance requires factory performance curve, UL certificate and NFPA 20 compliance letter.
Patterson, Aurora, Fairbanks Nijhuis and Armstrong substitution for Quebec projects
Patterson fire pump. Substitute UNIVAL UVFP-HSC or UVFP-ES at matching capacity and net pressure. Same UL 448/FM 1311/UL listing, same ANSI flange, same factory-witnessed performance curve. SIM accepts substitution on RBQ-licensed engineer-of-record submittal.
Aurora Pump 482/483/484. Substitute UVFP-HSC at matching GPM and psi duty point with French-language performance curve overlay.
Fairbanks Nijhuis 5400 series. Substitute UVFP-HSC-CI or UVFP-HSC-BRZ at matching duty point.
Armstrong 4280/4380/4600. Substitute UVFP-HSC or UVFP-VIL based on installation orientation. Match GPM, psi, NPSH required and driver selection.
Peerless/Grundfos/Xylem/ITT vertical turbine. Substitute UVFP-VT at matching capacity, net pressure, column length, bowl assembly and discharge head.
Driver and controller options for Quebec fire pump skids
Electric motor drivers. Eaton, Toshiba, WEG TEFC motors, 25 HP to 500 HP, 460V/575V 3-phase 60Hz, UL Listed and CSA certified for fire pump service per NFPA 20 Chapter 9 and CSA C22.1. Class F insulation, 1.15 service factor.
Diesel engine drivers. Clarke JDFP (John Deere), Clarke CFP (Cummins) and Iveco FPT diesel engines, UL Listed per NFPA 20 Chapter 11 with dual battery, dual fuel solenoid, governor and cooling loop. Sub-base fuel tank per NFPA 20 Section 11.4 sized for 8-hour run time. Emissions-compliant for Quebec MELCC requirements.
Fire pump controllers. Eaton, Cutler-Hammer, Metron (MFP series) and Firetrol (FTA/FDP series) UL Listed fire pump controllers with French-language operator interface option for Quebec. NEMA 2/3R/4/12 enclosure.
Jockey pump and controller. UNIVAL UVFP-JP Grundfos CR/CRE or Goulds eSV vertical multistage jockey pump with matched Firetrol FTA1100 or Metron jockey controller.
Quebec-specific delivery logistics / Logistique Quebec
Montreal downtown / centre-ville. Rue Sainte-Catherine, Rue Notre-Dame, Vieux-Montreal, Quartier International, Quartier des spectacles tower projects. Factory-assembled skids ship 2-day truck freight from Toronto HQ via Highway 401 with crane-lift coordination and narrow-street Montreal unloading.
REM / Metro / Trudeau airport. REM stations, STM Metro extensions, ADM Trudeau terminal expansions. Specialised security clearance, scheduled release windows and factory test witness coordination.
Laval, Longueuil, South Shore. Laval, Longueuil, Brossard, Boucherville, Saint-Hubert. Direct truck freight via Autoroute 15 or Autoroute 20. Factory test witness included for tower projects.
Quebec City, Gatineau, Sherbrooke. Capitale-Nationale, Outaouais and Estrie commercial and institutional projects. Consolidated truck freight from Montreal hub.
Related products for complete Montreal fire pump package
Grooved couplings and fittings. UV11 rigid and UV14 flexible couplings for suction and discharge. See Coupling Fittings Montreal.
Butterfly valves. UVB-G310 grooved butterfly with integral tamper. See Butterfly Valves Montreal.
Test and drain valves. UVT-TD-300 test header and flow meter accessories. See Test and Drain Valves Montreal.
Steel pipe. ABP-SCH40-BLK Schedule 40 for suction and discharge manifold. See Steel Pipes Montreal.
Frequently asked questions (Montreal)
Is UNIVAL accepted by SIM? Yes. UNIVAL fire pumps are UL 448 Listed and CAN/UL-S001 compliant with French-language factory performance curve and RBQ submittal package accepted at SIM witness testing.
Are French-language documents provided? Yes. ValveAtlas provides courbe de performance, manuel d’installation, rapport d’essai d’usine and RBQ submittal package in French per Loi 101 requirements.
When do I need diesel engine drive? NFPA 20 Section 9.3 requires diesel engine backup or secondary power source per Hydro-Quebec reliability criteria. Quebec high-rise and assembly occupancies typically require diesel drive or dual electric service.
What is the delivery time to Montreal? Factory-assembled skids ship 6 to 10 weeks from order. Stock HSC 500/1000 GPM ship 2 to 4 weeks. 2-day truck freight from Toronto HQ to Montreal metro.
How do I substitute Patterson or Aurora on a Montreal project? Submit substitution letter in French with UNIVAL UL 448/FM 1311/UL certificates, factory performance curve, dimensional drawings and NFPA 20 compliance. RBQ-licensed engineer approval follows; SIM accepts listed equivalent substitutions.
Contact ValveAtlas for Montreal fire pump quotation
For fire pump skid quotations, Patterson, Aurora, Fairbanks Nijhuis or Armstrong substitution submittals for SIM approval, or factory-assembled NFPA 20 skid packages for Montreal, Laval, Longueuil, Quebec City, Gatineau or Sherbrooke projects, email the project hydraulic calculations, building section, mechanical room plan and electrical single-line to burakpadr@gmail.com or use the contact form. Standard 48-hour turnaround with French-language documentation.
Why Engineers Trust ValveAtlas for Fire Pumps Montreal
ValveAtlas is the trusted fire pumps montreal supplier for fire protection contractors, mechanical engineers, and industrial end users across Canada, the United States, and London, UK. Every fire pumps montreal order ships with mill test certificates, UL/FM compliance letters, and dimensional drawings ready for engineer-of-record submittal. Reach the ValveAtlas team for fire pumps montreal quotations, code authority liaison, and project staging support.
Related Locations
- Steel Pipes Boston | UL/FM Schedule 10 and Schedule 40 Sprinkler Pipe BFD | ValveAtlas
- Fire Department Connections Toronto | UL 405/FM 1510/NFPA 14 Section 8.17 | ValveAtlas
- Fire Sprinklers New York | UL FM UNIVAL Sprinkler Supply | ValveAtlas
Codes & Industry Standards
Every fire pumps montreal shipment from ValveAtlas is supported by the following code and listing references: