Test and Drain Valves Toronto: UL and ULC Listed Inspector Test Valves, Main Drain Valves and Test-Drain-Alarm Manifolds for Toronto Sprinkler Projects
ValveAtlas supplies UL Listed and ULC Listed test and drain valves, inspector’s test connections, main drain valves and test/drain/alarm manifold assemblies to fire protection contractors, sprinkler subcontractors and ITM service companies across Toronto, GTA, Mississauga, Brampton, Vaughan, Markham and Ottawa. Toronto HQ warehouse, same-day pickup, OBC 3.2.5 submittals, and NFPA 25 compliance documentation for annual testing requirements.
This page is the technical reference for Toronto specifying engineers, ITM contractors and sprinkler installers selecting test and drain valves for wet pipe, dry pipe, pre-action and deluge sprinkler systems governed by OBC 3.2.5, NFPA 13, NFPA 25 and CAN/ULC-S536.
Test and drain valve range for Toronto projects
| Type | UNIVAL SKU | End connection | Pressure class | Listings | Sizes | Typical Toronto application |
|---|---|---|---|---|---|---|
| Test and drain combo valve | UVT-TD-300 | NPT threaded | 300 psi CWP | UL 789, FM Class 2090, ULC | 1″ to 2″ | Inspector test and main drain combined on Toronto riser |
| Test and drain 175 psi | UVT-TD-175 | NPT threaded | 175 psi CWP | UL 789, FM, ULC | 1″ to 2″ | Standard-pressure Toronto commercial and residential |
| Inspector’s test connection | UVT-IT-075 | 3/4″ NPT | 300 psi CWP | UL/FM/ULC | 3/4″ orifice | Remote end-of-line inspector test on Toronto sprinkler zone |
| Main drain valve | UVT-MD-200 | 2″ NPT | 300 psi CWP | UL/FM/ULC | 2″ | Main drain on Toronto wet alarm valve trim |
| Test/drain/alarm manifold | UVT-TDM | NPT per size | 300 psi CWP | UL/FM/ULC | 1″ and 2″ | Factory-assembled manifold for Toronto sprinkler riser base |
Why Toronto contractors choose ValveAtlas
UL and ULC dual listing. Every UVT-series test and drain valve is UL 789 Listed and CAN/ULC-S548 compliant. UL certificate and ULC certificate provided with every shipment for OBC 3.2.5 compliance and Toronto Fire Services inspection.
Factory-calibrated sight glass. UVT-TD-300 combo valve includes factory-calibrated sight glass for flow verification during NFPA 25 inspector test, eliminating contractor field-fabrication of sight glass assemblies.
NFPA 25 compliance package. ValveAtlas provides NFPA 25 compliance documentation with every shipment covering Chapter 5 (wet pipe), Chapter 7 (pre-action and deluge) and Chapter 13 (valves) ITM requirements for Toronto ITM service companies.
Same-day HQ pickup. Toronto HQ warehouse holds UVT-TD-300 and UVT-TDM in 1″ and 2″ for same-day pickup or next-day GTA delivery. Emergency orders ready within 4 hours of order confirmation.
Direct substitution of AGF, Victaulic TestMaster and Viking EcoBlazer. UVT-TD-300 is dimensionally interchangeable with AGF TestAnDrain 1011, Victaulic TestMaster Model 720 and Viking EcoBlazer test/drain combo valves per NPT end connection.
Code and listing acceptance for Toronto
Ontario Building Code 3.2.5. OBC 3.2.5 adopts NFPA 13 for sprinkler installation in Toronto. NFPA 13 Section 8.17 requires inspector’s test connection and main drain on every wet pipe sprinkler system; Section 8.17.4 specifies UL/ULC listed test and drain valves.
NFPA 25 inspection, testing and maintenance. NFPA 25 requires quarterly main drain tests, annual inspector’s tests and 5-year internal inspection of wet alarm valves. UVT-TD-300 and UVT-TDM support all NFPA 25 ITM procedures without disassembly.
Toronto Fire Services and TSSA. TFS inspectors accept UL/ULC listed test and drain valves at final inspection. TSSA registered sprinkler contractors use UVT-TDM for NFPA 25 annual certification of Toronto high-rise and assembly occupancies.
TDSB, TCDSB and University of Toronto. Toronto District School Board, Toronto Catholic District School Board, University of Toronto, York University and Ryerson campus construction specify UL/ULC listed test and drain valves on sprinkler submittals.
AGF, Victaulic and Viking substitution for Toronto projects
AGF TestAnDrain 1011. Substitute UVT-TD-300 test and drain. Same 300 psi CWP, same UL 789 / FM Class 2090 listing, same sight glass orifice sizing.
Victaulic TestMaster Model 720. Substitute UVT-TD-300.
Viking EcoBlazer test/drain. Substitute UVT-TD-300.
Reliable AGF Model 7000. Substitute UVT-TD-300.
Globe GL-TD test/drain. Substitute UVT-TD-300.
Toronto-specific delivery logistics
Toronto downtown and core. Yonge Street, Bay Street, King West, Queen West, Financial District, Entertainment District sprinkler riser projects — same-day pickup from Toronto HQ, next-day direct courier to job site.
GTA municipalities. Mississauga, Brampton, Vaughan, Markham, Richmond Hill, Oakville, Burlington — next-day direct van delivery from Toronto HQ. Bulk orders for multi-tower developments staged at HQ for scheduled releases.
Ottawa and Eastern Ontario. Ottawa, Kanata, Nepean commercial and federal projects — 2-day truck freight via Highway 401. NFPA 25 ITM contractor bulk orders supported.
Related products for complete Toronto sprinkler riser package
Wet alarm valves. UVW-1511-300 UL/ULC/FM wet alarm with integral trim. See Wet Alarm Valves Toronto.
Butterfly valves. UVB-G310 grooved butterfly with integral tamper for zone isolation. See Butterfly Valves Toronto.
Gate valves. UV0199 OS&Y flanged gate for Toronto riser bases. See Gate Valves.
Check valves. UL/ULC swing check for Toronto fire pump discharge and FDC trim. See Check Valves.
Grooved couplings. UV11 rigid and UV14 flexible couplings for sprinkler main connections. See Coupling Fittings Toronto.
Frequently asked questions (Toronto)
Is UVT-TD-300 accepted by TFS? Yes. UNIVAL UVT-series test and drain valves are UL 789 Listed and ULC compliant. UL and ULC certificates provided for every shipment; Toronto Fire Services inspectors accept at final inspection per OBC 3.2.5.
What orifice sizes are available? UVT-TD-300 factory-calibrated sight glass orifices match standard sprinkler K-factors: K2.8, K4.2, K5.6, K8.0, K11.2, K14.0, K16.8, K22.4, K25.2. Specify sprinkler K-factor on order; orifice sized to smallest sprinkler in zone per NFPA 13 Section 8.17.4.
Does the main drain meet NFPA 25 Chapter 13? Yes. UVT-MD-200 is UL Listed 2″ main drain, meeting NFPA 25 Section 13.2.5 quarterly main drain test requirements. Test port connection accepts standard NFPA 25 pressure gauge.
What is delivery time to Toronto? Same-day pickup from Toronto HQ for UVT-TD-300 and UVT-TDM standard stock. Next-day GTA van delivery. 2-day truck freight to Ottawa and Eastern Ontario.
How do I substitute AGF on an AGF-specified Toronto project? Submit substitution letter with UL 789 certificate, FM Class 2090 certificate, product data sheet and dimensional drawings showing UVT-TD-300 interchangeability. Engineer-of-record approval follows; TFS accepts listed equivalent substitutions.
Contact ValveAtlas for Toronto test and drain valve quotation
For test and drain valve quotations, AGF, Victaulic or Viking substitution submittals for TFS approval, or NFPA 25 ITM compliance packages on Toronto, GTA, Mississauga, Brampton, Vaughan, Markham or Ottawa projects, email the project specification and drawings to burakpadr@gmail.com or use the contact form. Same-day response on GTA urgent orders.
Why Engineers Trust ValveAtlas for Test Drain Valves Toronto
ValveAtlas is the trusted test drain valves toronto supplier for fire protection contractors, mechanical engineers, and industrial end users across Canada, the United States, and London, UK. Every test drain valves toronto order ships with mill test certificates, UL/FM compliance letters, and dimensional drawings ready for engineer-of-record submittal. Reach the ValveAtlas team for test drain valves toronto quotations, code authority liaison, and project staging support.
Related Locations
- Butterfly Valves Boston | UL FM Grooved Wafer Lug with Integral Tamper BFD 780 CMR | ValveAtlas
- Vannes a Coin Montreal | UL 262/FM 1120/ULC NFPA 13 | ValveAtlas
- Post Indicator Valves New York: UL 789/FM 1110 Listed PIV and PIVA with FDNY-Accepted Tamper Supervision for NYC Supertall and Hospital Fire Mains
Codes & Industry Standards
Every test drain valves toronto shipment from ValveAtlas is supported by the following code and listing references:
