Gate Valves for Fire Protection: UL, ULC and FM Listed UNIVAL UV0199 and UV0299 Supply
ValveAtlas supplies UL Listed, ULC Listed and FM Approved UNIVAL UV0199 OS&Y (outside screw and yoke) gate valves and UV0299 NRS (non-rising stem) gate valves for sprinkler riser isolation, fire pump suction and discharge, underground water main tie-ins, post indicator assembly and standpipe zone control on projects in Toronto, Montreal, New York, Boston and London.
This page is the technical reference for specifying engineers, EPC firms and mechanical subcontractors selecting gate valves on fire protection systems governed by NFPA 13, NFPA 20, NFPA 24, BS EN 12845 and Approved Document B.
UNIVAL gate valve range
| UNIVAL SKU | Type | End connection | Pressure class | Listings | Sizes |
|---|---|---|---|---|---|
| UV0199 | OS&Y (outside screw and yoke) indicating gate | Flanged ANSI 150 or ANSI 300 | 300 psi CWP | UL, ULC, FM | 2″ to 12″ |
| UV0299 | NRS (non-rising stem) gate with operating nut | Flanged or mechanical joint (MJ) | 300 psi CWP | UL, ULC, FM | 2″ to 12″ |
| UV0800-IP | Post indicator valve (PIV) above-grade indicator | MJ or flanged, buried with vertical stem | 250 psi CWP | UL, ULC, FM | 4″ to 10″ |
OS&Y vs NRS vs PIV selection
OS&Y gate (UV0199). Used where the valve is visible from within the building: sprinkler riser base, fire pump suction, fire pump discharge, standpipe zone control. The threaded stem rises visibly out of the yoke when open; the visible stem position is the indicating feature. Tamper switch on the yoke monitors open/close position.
NRS gate (UV0299). Used where the valve is buried or in a vault: underground water main tie-ins, main building shutoff in a vault. The stem does not rise externally; the operating nut at the top is turned by a tee-handle wrench (key). Indication is provided through a separate post indicator assembly (PIA) above grade, or through a valve-position monitoring device in the vault.
PIV (UV0800-IP). The above-grade indicator for a buried NRS gate valve. The PIV consists of a steel post extending from the buried valve to 32 to 40 inches above grade, with an indicator window showing “OPEN” or “SHUT” as the buried valve is operated via the wrench nut at the top of the post. NFPA 24 Section 6.3 requires PIV on underground water main tie-ins that serve fire protection systems where the water main enters the property.
Listings and code acceptance
UL 262. UV0199 and UV0299 carry UL 262 (gate valves for fire protection service) listing.
FM Approvals Class 1110/1120. UV0199 and UV0299 listed for FM-insured properties. FM surveyors, RSA, Aviva, Zurich, Allianz, AXA Commercial, Chubb, AIG, Travelers and Intact accept the FM certificate.
ULC listing for Canadian projects. CAN/ULC-S543 covers the SKUs for Canadian NFPA 13 projects.
LPCB and UK acceptance. BS EN 12845 Section 15 (valves) recognition via LPS 1039 equivalent scope. UK insurance surveyors confirm LPCB-specific acceptance.
Where gate valves are installed
Sprinkler riser base. UV0199 OS&Y immediately upstream of the wet alarm valve (UVW-1511-300), dry pipe valve (UVD-2511-300) or pre-action valve (UVPR-5311-300). Provides system isolation for maintenance and testing.
Fire pump suction. UV0199 OS&Y flanged on the suction side of every fire pump per NFPA 20 Section 4.16. Listed 300 psi CWP covers typical 100 to 175 psi standpipe service.
Fire pump discharge. UV0199 OS&Y flanged on the discharge side. Where high-rise fire pump discharge exceeds 300 psi (500 psi class for tall-building standpipes), coordinate with ValveAtlas for 500 psi-class flanged gate valve.
Underground water main tie-ins. UV0299 NRS gate in a valve vault at the property line, above which a PIV (UV0800-IP) is installed for visual indication. NFPA 24 Section 6.3 covers PIV requirements.
Standpipe zone control. UV0199 OS&Y at each standpipe zone inlet. NFPA 14 Chapter 6 requires listed indicating valve with tamper supervision.
Substitution matrix from Victaulic, Nibco, Milwaukee, Mueller
Victaulic Series 771 OS&Y gate. Substitute UNIVAL UV0199. UL/ULC/FM listed, 300 psi CWP, flanged connection. See the UNIVAL vs Victaulic comparison.
Nibco F-607-OTS and F-607-RWS OS&Y gate. Substitute UV0199. UL/ULC/FM listed, 300 psi CWP, flanged.
Milwaukee MW-F-2882 OS&Y gate. Substitute UV0199. UL/FM listed.
Mueller A-2361-20 NRS gate. Substitute UV0299 NRS. UL/ULC/FM listed, MJ or flanged.
Kennedy K-81A PIV. Substitute UV0800-IP post indicator valve. UL/ULC/FM listed.
Regional stock and delivery for gate valves
Toronto. UV0199 2″ to 8″ OS&Y flanged in stock at Toronto HQ for same-day shipment. UV0299 and UV0800-IP stocked for Ontario underground water main projects.
Montreal. Next-day truck freight from Toronto. RBQ submittals with ULC certificate. French-language technical documentation available.
New York. 2-day truck freight from Toronto. NYC DOB and FDNY accept UL certificate. High-rise fire pump discharge gate valves pre-staged for JFK, LGA and Manhattan construction.
Boston. 2-day truck freight from Toronto. BFD and 780 CMR acceptance under UL listing.
London UK. UK partner warehouse stocks 4″ and 6″ UV0199 OS&Y. 8″ and above on 5 to 7 day air freight via Heathrow.
Related products for complete riser and water main service
Alarm valves. UVW-1511-300 wet alarm, UVD-2511-300 dry pipe, UVPR-5311-300 pre-action, UVPPD deluge downstream of the gate valve.
Butterfly valves. UVB-G310 grooved butterfly for zone-level isolation downstream of gate. See Butterfly Valves.
Check valves. Listed swing check valve on fire pump discharge paired with UV0199 gate, and on backflow preventer assembly upstream.
Grooved couplings. UV11 rigid and UV14 flexible on the flanged-to-grooved transitions. See Coupling Fittings.
Tamper switches. UL-listed tamper switches on every indicating valve (Potter PIBV or System Sensor equivalents) wired to the fire alarm panel per NFPA 72 Section 17.16.
Frequently asked questions
What is the difference between OS&Y and NRS? OS&Y has a rising stem (the threaded stem rises out of the yoke when opening, providing visual indication). NRS has a non-rising stem (stem stays internal; opening is indicated by a separate post indicator or vault-monitoring device). OS&Y is used above-grade where visible; NRS is used below-grade or in vaults.
Does UV0199 require a tamper switch? Yes. NFPA 72 Section 17.16 and BS EN 12845 Section 20 require tamper supervision on every indicating valve controlling a sprinkler or standpipe zone. UV0199 is shipped with factory-installed tamper switch on the yoke.
What pressure class covers high-rise fire pump discharge? Standard UV0199 is rated 300 psi CWP. For tall-building standpipe discharge at 500 psi (Zone 2 or Zone 3 high-rise pump discharge), ValveAtlas coordinates the 500 psi-class OS&Y gate variant. Specify the pump discharge pressure on the purchase order; ValveAtlas confirms stock position or factory lead time.
Can UV0299 NRS be used above-grade? Technically yes, but the NRS configuration has no visible stem to indicate open/close. Above-grade use of NRS requires a post indicator assembly (PIA) for visual indication, which defeats the purpose of NRS cost savings. Use UV0199 OS&Y above-grade; use UV0299 NRS only in buried or vaulted installations.
What is the difference between UV0800-IP PIV and post indicator assembly? UV0800-IP is the complete PIV: NRS valve + vertical buried stem + above-grade indicator post as one listed assembly. A PIA (post indicator assembly) is the post indicator portion alone, retrofit onto an existing NRS gate valve. ValveAtlas supplies both UV0800-IP complete PIV for new construction and PIA retrofits for existing installations.
Contact ValveAtlas for a gate valve quotation
For gate valve quotations, submittal packages substituting UNIVAL for Victaulic, Nibco, Milwaukee, Mueller or Kennedy specifications on Toronto, Montreal, New York, Boston or London projects, email the project specification and drawings to burakpadr@gmail.com or use the contact form. Standard turnaround is 48 hours.
For the complete UNIVAL cross-reference chart, see the UNIVAL Cross-Reference.
Why Engineers Trust ValveAtlas for Gate Valves Fire Protection
ValveAtlas is the trusted gate valves fire protection supplier for fire protection contractors, mechanical engineers, and industrial end users across Canada, the United States, and London, UK. Every gate valves fire protection order ships with mill test certificates, UL/FM compliance letters, and dimensional drawings ready for engineer-of-record submittal. Reach the ValveAtlas team for gate valves fire protection quotations, code authority liaison, and project staging support.
Related Locations
- HVAC Check Valves New York | Swing, Dual-Plate and Silent | ValveAtlas
- Seamless Steel Pipes Toronto | Aydin Boru ASTM A53/A106/API 5L Seamless Line Pipe | ValveAtlas
- Dry Pipe Valves Boston | UL/FM NFPA 13 LMA Hospital Dry Pipe BFD | ValveAtlas
- Fournisseur en protection incendie à Montréal, Québec
Codes & Industry Standards
Every gate valves fire protection shipment from ValveAtlas is supported by the following code and listing references: