Zone Control Valves New York: UL/FM/ULC Listed Floor Control Valve Assemblies with Butterfly or OS&Y Gate Valve, Waterflow Switch and Drain for NFPA 13 High-Rise Sprinkler Floor Isolation
ValveAtlas supplies UL Listed, FM Approved and ULC Certified zone control valve assemblies (UVZC-100, UVZC-150, UVZC-200 and UVZC-250) with butterfly or OS&Y gate isolation valve, integrated waterflow switch (UVWF paddle), sight glass drain (UVTD test and drain) and pressure gauge package mounted on a common manifold to fire protection contractors and mechanical subs across New York. Full submittal for FDNY approval under NYC Building Code BC 2022.
Technical reference for New York high-rise sprinkler designers and floor control valve specifiers at JFK, One World Trade Center, Empire State Building and Columbia University. Zone control valve assembly (ZCV) provides per-floor isolation, inspector test, drain and flow detection at each floor or zone sprinkler main per NFPA 13 Section 8.16. Single-point connection reduces on-site labor and field-labeled factory assembly.
UNIVAL UVZC product range for New York projects
UVZC-100 through UVZC-250 covers DN100, DN150, DN200, DN250 floor mains with UVB-G310 grooved butterfly (UL/ULC/FM) or UV0199 OS&Y gate (UL/ULC/FM) as isolation valve, UVWF paddle-type waterflow switch (UL 346/FM 1049), UVTD single-handle test and drain valve (UL 1726), bronze pressure gauges, sight glass and drain piping. Assembly ships fully piped with tamper switches pre-wired to leader terminal strip. Factory hydrostatic tested to 300 psi.
Why New York contractors choose ValveAtlas zone control valves
Factory-assembled single-point floor control. UVZC arrives fully piped and pressure tested. Contractor connects one inlet flange to riser and one outlet to floor sprinkler main. No field piping of test, drain, gauge or flow switch harness.
UL/FM/ULC listed components throughout. Every valve and switch in the assembly carries individual UL or FM listing. The assembly itself carries UL system listing for floor control valve application per NFPA 13 Section 8.16.1.
Tamper switches pre-wired. Butterfly integral tamper and OS&Y gate supervisory tamper switch terminated to a labeled junction box. Contractor pulls one multi-conductor to the fire alarm panel zone card.
Competitor substitution for New York projects
Victaulic Series 705/791 floor control valve, Potter Roemer ZCV, AGF 1000 floor control valve and Viking FCV-100 all substitute one-for-one with UVZC at matching size and isolation-valve type. Same component-level UL/FM/ULC listing. Factory submittal available for FDNY acceptance.
Related New York products
See also: Butterfly valves New York, Gate valves New York, Waterflow switches New York, Test and drain valves New York.
Contact ValveAtlas for New York zone control valves quotation
Email UVZC quotation requests and Victaulic/Potter Roemer/AGF/Viking substitution submittals for FDNY approval to info@valve-atlas.com.
Why Engineers Trust ValveAtlas for Zone Control Valves New
ValveAtlas is the trusted zone control valves new supplier for fire protection contractors, mechanical engineers, and industrial end users across Canada, the United States, and London, UK. Every zone control valves new order ships with mill test certificates, UL/FM compliance letters, and dimensional drawings ready for engineer-of-record submittal. Reach the ValveAtlas team for zone control valves new quotations, code authority liaison, and project staging support.
Related Locations
- Seamless Steel Pipes Montreal | Aydin Boru ASTM A53/A106/API 5L Seamless Line Pipe | ValveAtlas
- HVAC Butterfly Valves Toronto | UNIVAL Wafer & Lug BWN/BLN Series | ValveAtlas
- Fire Protection Supplier in Boston, Massachusetts
Codes & Industry Standards
Every zone control valves new shipment from ValveAtlas is supported by the following code and listing references: