{"id":44367,"date":"2026-09-30T03:56:15","date_gmt":"2026-09-30T03:56:15","guid":{"rendered":"https:\/\/valve-atlas.com\/valve-actuators-automation\/electric-actuated-valve\/"},"modified":"2026-09-30T03:56:15","modified_gmt":"2026-09-30T03:56:15","slug":"electric-actuated-valve","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/valve-actuators-automation\/electric-actuated-valve\/","title":{"rendered":"Electric Actuated Valve: Quarter-Turn and Multi-Turn"},"content":{"rendered":"<div class=\"vx-page\"><section class=\"vx-intro vx-intro-has-media\"><div class=\"vx-intro-text\"><nav class=\"vx-crumbs\" aria-label=\"chapelure\"><a href=\"\/\">Accueil<\/a><i>\/<\/i><a href=\"\/industrial-valves\/\">Vannes industrielles<\/a><i>\/<\/i><a href=\"\/valve-actuators-automation\/\">Vannes actionn\u00e9es<\/a><i>\/<\/i><span>Electric Actuated Valve<\/span><\/nav><p class=\"vx-eyebrow\">Vannes actionn\u00e9es<\/p><div class=\"vx-lead\"><p>Electric actuated valves are used to open and close valves remotely, or to position them proportionally, where compressed air is not available or at remote sites. Quarter-turn types are used on ball and butterfly valves, multi-turn types on gate and globe valves.<\/p><\/div><div class=\"vx-chips\"><span>4\u201320 mA<\/span><span>24 V DC \/ 230 V AC \/ 380 V AC<\/span><span>IP67<\/span><span>ATEX option<\/span><\/div><div class=\"vx-actions\"><a class=\"vx-btn\" href=\"\/contact\/\">Demander un devis<\/a><a class=\"vx-btn vx-btn-line\" href=\"\/wp-content\/uploads\/2026\/09\/valveatlas-datasheet-electric-actuated-valve.pdf\" target=\"_blank\" rel=\"noopener\">T\u00e9l\u00e9charger la fiche technique (PDF)<\/a><\/div><\/div><figure class=\"vx-intro-media\"><img fetchpriority=\"high\" decoding=\"async\" class=\"vx-intro-img wp-image-44285\" src=\"\/wp-content\/uploads\/2026\/09\/electric-actuated-ball-valve-768x576.jpg\" srcset=\"\/wp-content\/uploads\/2026\/09\/electric-actuated-ball-valve-300x225.jpg 300w, \/wp-content\/uploads\/2026\/09\/electric-actuated-ball-valve-768x576.jpg 768w, \/wp-content\/uploads\/2026\/09\/electric-actuated-ball-valve-1024x768.jpg 1024w, \/wp-content\/uploads\/2026\/09\/electric-actuated-ball-valve.jpg 1200w\" sizes=\"(max-width: 900px) 100vw, 480px\" width=\"1200\" height=\"900\" alt=\"Electric actuated flanged ball valve\" loading=\"eager\"><\/figure><\/section>\n<h2 class=\"vx-h2\">Aper\u00e7u<\/h2><p>On on-off types, torque and limit switches protect the valve; on modulating types, position control and feedback use a 4\u201320 mA or 0\u201310 V signal. During a power failure the valve can be operated with the manual handwheel; where a fail-safe position is required, backup power (battery or supercapacitor) or a spring return pneumatic solution is considered.<\/p>\n<h2 class=\"vx-h2\">Sp\u00e9cifications techniques<\/h2><div class=\"vx-table-wrap\"><table class=\"vx-table vx-spec\"><tbody><tr><th scope=\"row\">Taper<\/th><td>Quarter-turn; multi-turn (with gearbox)<\/td><\/tr><tr><th scope=\"row\">Control<\/th><td>On-off; modulating 4\u201320 mA \/ 0\u201310 V; Modbus and similar communication options<\/td><\/tr><tr><th scope=\"row\">Power supply<\/th><td>24 V DC, 230 V AC, 380 V AC<\/td><\/tr><tr><th scope=\"row\">Protection<\/th><td>IP67 \/ IP68; ATEX (2014\/34\/EU) Ex d options<\/td><\/tr><tr><th scope=\"row\">Features<\/th><td>Manual handwheel, torque and limit switches, position indicator<\/td><\/tr><\/tbody><\/table><\/div>\n<h2 class=\"vx-h2\">Caract\u00e9ristiques principales<\/h2><ul class=\"vx-check\"><li>No compressed air required<\/li><li>Proportional position control<\/li><li>Emergency operation by manual handwheel<\/li><li>Supplied assembled and function-tested<\/li><\/ul>\n<h2 class=\"vx-h2\">Documentation et tests<\/h2><p>Dans le cadre de projets industriels, la documentation technique est aussi importante que la vanne elle-m\u00eame. Nous confirmons la certification et le p\u00e9rim\u00e8tre des tests pour chaque \u00e9l\u00e9ment d\u00e8s l&#039;\u00e9tablissement du devis.<\/p><ul class=\"vx-check\"><li><strong>EN 10204 3.1 certificats de mat\u00e9riaux<\/strong> pour les pi\u00e8ces sous pression et en contact avec le fluide, tra\u00e7abilit\u00e9 par num\u00e9ro de coul\u00e9e<\/li><li><strong>EN 10204 3.2<\/strong> avec inspection par un tiers, sur demande<\/li><li><strong>Rapports d&#039;essais de pression<\/strong> essais de coque, de si\u00e8ge et, le cas \u00e9ch\u00e9ant, de gaz, conformes aux normes API 598 ou EN 12266-1<\/li><li><strong>Certificats d&#039;essai au feu<\/strong> (API 607 \/ ISO 10497) pour les conceptions test\u00e9es en mati\u00e8re de r\u00e9sistance au feu<\/li><li><strong>Rapports PMI<\/strong> pour les mat\u00e9riaux en alliage et en acier inoxydable<\/li><li><strong>Rapports d&#039;inspection dimensionnelle, visuelle et de rev\u00eatement<\/strong><\/li><li><strong>D\u00e9claration CE PDSE 2014\/68\/UE<\/strong> pour les \u00e9quipements relevant de son champ d&#039;application<\/li><li><strong>D\u00e9claration de conformit\u00e9 NACE MR0175 \/ ISO 15156<\/strong> pour service acide (H\u2082S)<\/li><\/ul>\n<h2 class=\"vx-h2\">Fiche technique<\/h2><ul class=\"vx-dl-list\"><li><a href=\"\/wp-content\/uploads\/2026\/09\/valveatlas-datasheet-electric-actuated-valve.pdf\" target=\"_blank\" rel=\"noopener\"><span class=\"vx-pdf\">PDF<\/span><span class=\"vx-dl-t\">Electric Actuated Valve: technical datasheet<\/span><span class=\"vx-dl-m\">PDF \u00b7 Anglais \u00b7 2\u20133 pages<\/span><\/a><\/li><\/ul>\n<section class=\"vx-faq\"><h2 class=\"vx-h2\">Foire aux questions<\/h2><details class=\"vx-faq-item\"><summary>Electric or pneumatic actuator?<\/summary><div class=\"vx-faq-a\"><p>Where there is no compressed air on site, where operating frequency is low, or at remote locations, an electric actuator is practical. Where fast closing and a fail-safe position on power loss are required, a spring return pneumatic actuator is usually the better choice; see our <a href=\"\/2026\/07\/25\/electric-vs-pneumatic-valve-actuators\/\">electric vs pneumatic actuator comparison<\/a>.<\/p><\/div><\/details><\/section>\n<h2 class=\"vx-h2\">Produits associ\u00e9s<\/h2><div class=\"vx-grid\"><a class=\"vx-card vx-card-media\" href=\"\/valve-actuators-automation\/pneumatic-actuated-valve\/\"><div class=\"vx-card-img\"><img class=\"vx-thumb wp-image-44286 lazyload\" data-src=\"\/wp-content\/uploads\/2026\/09\/pneumatic-actuated-valve-768x576.jpg\" data-srcset=\"\/wp-content\/uploads\/2026\/09\/pneumatic-actuated-valve-300x225.jpg 300w, \/wp-content\/uploads\/2026\/09\/pneumatic-actuated-valve-768x576.jpg 768w, \/wp-content\/uploads\/2026\/09\/pneumatic-actuated-valve-1024x768.jpg 1024w, \/wp-content\/uploads\/2026\/09\/pneumatic-actuated-valve.jpg 1200w\" data-sizes=\"auto, (max-width: 700px) 100vw, 380px\" width=\"1200\" height=\"900\" alt=\"Pneumatic actuated valve with positioner and handwheel\" decoding=\"async\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1200px; --smush-placeholder-aspect-ratio: 1200\/900;\"><\/div><div class=\"vx-card-body\"><h3>Pneumatic Actuated Valve<\/h3><p>Double-acting and fail-safe; rack and pinion, scotch-yoke; NAMUR accessories.<\/p><span class=\"vx-more\">Voir les d\u00e9tails<\/span><\/div><\/a><\/div>\n<section class=\"vx-cta\"><div><h2>Request a quote: Electric Actuated Valve<\/h2><p>Partagez votre liste de vannes, votre fiche technique ou le cahier des charges de votre projet. Nous examinons les normes, les mat\u00e9riaux et la documentation ligne par ligne et vous soumettons une offre d\u00e9taill\u00e9e, toute d\u00e9rogation au cahier des charges \u00e9tant mentionn\u00e9e par \u00e9crit.<\/p><\/div><div class=\"vx-cta-actions\"><a class=\"vx-btn\" href=\"\/contact\/\">Demander un devis<\/a><a class=\"vx-cta-link\" href=\"mailto:info@valve-atlas.com\">info@valve-atlas.com<\/a><a class=\"vx-cta-link\" href=\"tel:+16475537109\">+1 (647) 553-7109<\/a><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>Home\/Industrial Valves\/Actuated Valves\/Electric Actuated Valve Actuated Valves Electric actuated valves are used to open and close valves remotely, or to position them proportionally, where compressed air is not available or at remote sites. Quarter-turn types are used on ball and butterfly valves, multi-turn types on gate and globe valves. 4\u201320 mA24 V DC \/ 230&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":44056,"menu_order":31,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"iawp_total_views":0,"footnotes":""},"class_list":["post-44367","page","type-page","status-publish","hentry","description-off"],"acf":[],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44367","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=44367"}],"version-history":[{"count":0,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44367\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44056"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=44367"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}