{"id":44364,"date":"2026-09-30T03:56:13","date_gmt":"2026-09-30T03:56:13","guid":{"rendered":"https:\/\/valve-atlas.com\/industrial-strainers-steam\/y-strainer\/"},"modified":"2026-09-30T03:56:13","modified_gmt":"2026-09-30T03:56:13","slug":"y-strainer","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/industrial-strainers-steam\/y-strainer\/","title":{"rendered":"Y Strainer: Flanged, Threaded and Butt-Weld"},"content":{"rendered":"<div class=\"vx-page\"><section class=\"vx-intro vx-intro-has-media\"><div class=\"vx-intro-text\"><nav class=\"vx-crumbs\" aria-label=\"chapelure\"><a href=\"\/\">Accueil<\/a><i>\/<\/i><a href=\"\/industrial-valves\/\">Vannes industrielles<\/a><i>\/<\/i><a href=\"\/industrial-strainers-steam\/\">Industrial Strainers<\/a><i>\/<\/i><span>Y Strainer<\/span><\/nav><p class=\"vx-eyebrow\">Industrial Strainers<\/p><div class=\"vx-lead\"><p>A Y strainer is a compact filtering element in which the screen chamber sits on an angled branch of the body. Installed upstream of pumps, control valves, steam traps and instruments, it captures weld slag, rust and particles in the line.<\/p><\/div><div class=\"vx-chips\"><span>Y-type<\/span><span>PN16 \/ PN40<\/span><span>Class 150 \/ 300<\/span><span>304 \/ 316 screen<\/span><\/div><div class=\"vx-actions\"><a class=\"vx-btn\" href=\"\/contact\/\">Demander un devis<\/a><a class=\"vx-btn vx-btn-line\" href=\"\/wp-content\/uploads\/2026\/09\/valveatlas-datasheet-y-strainer.pdf\" target=\"_blank\" rel=\"noopener\">T\u00e9l\u00e9charger la fiche technique (PDF)<\/a><\/div><\/div><figure class=\"vx-intro-media\"><img fetchpriority=\"high\" decoding=\"async\" class=\"vx-intro-img wp-image-44287\" src=\"\/wp-content\/uploads\/2026\/09\/flanged-y-strainer-768x576.jpg\" srcset=\"\/wp-content\/uploads\/2026\/09\/flanged-y-strainer-300x225.jpg 300w, \/wp-content\/uploads\/2026\/09\/flanged-y-strainer-768x576.jpg 768w, \/wp-content\/uploads\/2026\/09\/flanged-y-strainer-1024x768.jpg 1024w, \/wp-content\/uploads\/2026\/09\/flanged-y-strainer.jpg 1200w\" sizes=\"(max-width: 900px) 100vw, 480px\" width=\"1200\" height=\"900\" alt=\"Flanged Y strainer\" loading=\"eager\"><\/figure><\/section>\n<h2 class=\"vx-h2\">Aper\u00e7u<\/h2><p>On liquid lines the screen leg is installed pointing down; on steam and gas lines it is installed horizontally, pointing sideways. With a valve fitted to the blow-off connection on the screen cover, partial cleaning can be done during operation. The screen opening is selected for the protected equipment; with fine screens, a differential pressure gauge is recommended. For a comparison with basket and duplex strainers, see our <a href=\"\/2026\/05\/31\/y-strainers-vs-basket-strainers-vs-duplex-strainers-selection-guide\/\">guide de s\u00e9lection des passoires<\/a>.<\/p>\n<div class=\"vx-gallery\"><figure><img class=\"vx-gal-img wp-image-44288 lazyload\" data-src=\"\/wp-content\/uploads\/2026\/09\/threaded-y-strainers-768x576.jpg\" data-srcset=\"\/wp-content\/uploads\/2026\/09\/threaded-y-strainers-300x225.jpg 300w, \/wp-content\/uploads\/2026\/09\/threaded-y-strainers-768x576.jpg 768w, \/wp-content\/uploads\/2026\/09\/threaded-y-strainers-1024x768.jpg 1024w, \/wp-content\/uploads\/2026\/09\/threaded-y-strainers.jpg 1200w\" data-sizes=\"auto, (max-width: 700px) 100vw, 380px\" width=\"1200\" height=\"900\" alt=\"Threaded Y strainers\" decoding=\"async\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1200px; --smush-placeholder-aspect-ratio: 1200\/900;\"><\/figure><\/div>\n<h2 class=\"vx-h2\">Sp\u00e9cifications techniques<\/h2><div class=\"vx-table-wrap\"><table class=\"vx-table vx-spec\"><tbody><tr><th scope=\"row\">Connexions terminales<\/th><td>Flanged (EN 1092-1 \/ ASME B16.5), threaded, butt-weld<\/td><\/tr><tr><th scope=\"row\">Pressure rating<\/th><td>PN16, PN40; Class 150, 300<\/td><\/tr><tr><th scope=\"row\">Corps<\/th><td>WCB \/ A105, CF8 \/ CF8M<\/td><\/tr><tr><th scope=\"row\">Screen<\/th><td>304 \/ 316 perforated plate or wire mesh<\/td><\/tr><tr><th scope=\"row\">Options<\/th><td>Blow-off connection, magnetic insert, differential pressure gauge connections<\/td><\/tr><\/tbody><\/table><\/div>\n<h2 class=\"vx-h2\">Caract\u00e9ristiques principales<\/h2><ul class=\"vx-check\"><li>Compact and economical<\/li><li>Horizontal and vertical (downward flow) installation<\/li><li>Cleaning in operation via blow-off<\/li><\/ul>\n<h2 class=\"vx-h2\">Documentation et tests<\/h2><p>Dans le cadre de projets industriels, la documentation technique est aussi importante que la vanne elle-m\u00eame. Nous confirmons la certification et le p\u00e9rim\u00e8tre des tests pour chaque \u00e9l\u00e9ment d\u00e8s l&#039;\u00e9tablissement du devis.<\/p><ul class=\"vx-check\"><li><strong>EN 10204 3.1 certificats de mat\u00e9riaux<\/strong> pour les pi\u00e8ces sous pression et en contact avec le fluide, tra\u00e7abilit\u00e9 par num\u00e9ro de coul\u00e9e<\/li><li><strong>EN 10204 3.2<\/strong> avec inspection par un tiers, sur demande<\/li><li><strong>Rapports d&#039;essais de pression<\/strong> essais de coque, de si\u00e8ge et, le cas \u00e9ch\u00e9ant, de gaz, conformes aux normes API 598 ou EN 12266-1<\/li><li><strong>Certificats d&#039;essai au feu<\/strong> (API 607 \/ ISO 10497) pour les conceptions test\u00e9es en mati\u00e8re de r\u00e9sistance au feu<\/li><li><strong>Rapports PMI<\/strong> pour les mat\u00e9riaux en alliage et en acier inoxydable<\/li><li><strong>Rapports d&#039;inspection dimensionnelle, visuelle et de rev\u00eatement<\/strong><\/li><li><strong>D\u00e9claration CE PDSE 2014\/68\/UE<\/strong> pour les \u00e9quipements relevant de son champ d&#039;application<\/li><li><strong>D\u00e9claration de conformit\u00e9 NACE MR0175 \/ ISO 15156<\/strong> pour service acide (H\u2082S)<\/li><\/ul>\n<h2 class=\"vx-h2\">Fiche technique<\/h2><ul class=\"vx-dl-list\"><li><a href=\"\/wp-content\/uploads\/2026\/09\/valveatlas-datasheet-y-strainer.pdf\" target=\"_blank\" rel=\"noopener\"><span class=\"vx-pdf\">PDF<\/span><span class=\"vx-dl-t\">Y Strainer: technical datasheet<\/span><span class=\"vx-dl-m\">PDF \u00b7 Anglais \u00b7 2\u20133 pages<\/span><\/a><\/li><\/ul>\n<section class=\"vx-faq\"><h2 class=\"vx-h2\">Foire aux questions<\/h2><details class=\"vx-faq-item\"><summary>How is the screen opening of a Y strainer selected?<\/summary><div class=\"vx-faq-a\"><p>By the largest particle size the protected equipment can tolerate. Perforated plate is generally used for pumps, finer wire mesh for control valves and instruments. The finer the screen, the faster it clogs and the higher the pressure drop.<\/p><\/div><\/details><\/section>\n<h2 class=\"vx-h2\">Produits associ\u00e9s<\/h2><div class=\"vx-grid\"><a class=\"vx-card vx-card-media\" href=\"\/industrial-strainers-steam\/basket-strainer\/\"><div class=\"vx-card-img vx-card-ph\"><span>Basket strainer<\/span><\/div><div class=\"vx-card-body\"><h3>Basket Strainer<\/h3><p>High dirt-holding capacity; simplex and duplex, uninterrupted operation.<\/p><span class=\"vx-more\">Voir les d\u00e9tails<\/span><\/div><\/a><\/div>\n<section class=\"vx-cta\"><div><h2>Request a quote: Y Strainer<\/h2><p>Partagez votre liste de vannes, votre fiche technique ou le cahier des charges de votre projet. Nous examinons les normes, les mat\u00e9riaux et la documentation ligne par ligne et vous soumettons une offre d\u00e9taill\u00e9e, toute d\u00e9rogation au cahier des charges \u00e9tant mentionn\u00e9e par \u00e9crit.<\/p><\/div><div class=\"vx-cta-actions\"><a class=\"vx-btn\" href=\"\/contact\/\">Demander un devis<\/a><a class=\"vx-cta-link\" href=\"mailto:info@valve-atlas.com\">info@valve-atlas.com<\/a><a class=\"vx-cta-link\" href=\"tel:+16475537109\">+1 (647) 553-7109<\/a><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>Home\/Industrial Valves\/Industrial Strainers\/Y Strainer Industrial Strainers A Y strainer is a compact filtering element in which the screen chamber sits on an angled branch of the body. Installed upstream of pumps, control valves, steam traps and instruments, it captures weld slag, rust and particles in the line. Y-typePN16 \/ PN40Class 150 \/ 300304 \/ 316&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":44057,"menu_order":28,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"iawp_total_views":0,"footnotes":""},"class_list":["post-44364","page","type-page","status-publish","hentry","description-off"],"acf":[],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44364","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=44364"}],"version-history":[{"count":0,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44364\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44057"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=44364"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}