{"id":44361,"date":"2026-09-30T03:56:11","date_gmt":"2026-09-30T03:56:11","guid":{"rendered":"https:\/\/valve-atlas.com\/cryogenic-valves-lng\/cryogenic-gate-globe-valve\/"},"modified":"2026-09-30T03:56:11","modified_gmt":"2026-09-30T03:56:11","slug":"cryogenic-gate-globe-valve","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/cryogenic-valves-lng\/cryogenic-gate-globe-valve\/","title":{"rendered":"Cryogenic Gate and Globe Valves: BS 6364, \u2212196 \u00b0C"},"content":{"rendered":"<div class=\"vx-page\"><section class=\"vx-intro vx-intro-has-media\"><div class=\"vx-intro-text\"><nav class=\"vx-crumbs\" aria-label=\"chapelure\"><a href=\"\/\">Accueil<\/a><i>\/<\/i><a href=\"\/industrial-valves\/\">Vannes industrielles<\/a><i>\/<\/i><a href=\"\/cryogenic-valves-lng\/\">Vannes cryog\u00e9niques<\/a><i>\/<\/i><span>Cryogenic Gate and Globe Valves<\/span><\/nav><p class=\"vx-eyebrow\">Vannes cryog\u00e9niques<\/p><div class=\"vx-lead\"><p>Cryogenic gate and globe valves are used for isolation and flow regulation in LNG and industrial gas plants. An extended bonnet and austenitic stainless steel suitable for low temperatures are their key features; low-temperature testing to BS 6364 is performed as a type test or on request.<\/p><\/div><div class=\"vx-chips\"><span>BS 6364<\/span><span>ISO 28921-1<\/span><span>Extended bonnet<\/span><span>\u2212196 \u00b0C<\/span><\/div><div class=\"vx-actions\"><a class=\"vx-btn\" href=\"\/contact\/\">Demander un devis<\/a><a class=\"vx-btn vx-btn-line\" href=\"\/wp-content\/uploads\/2026\/09\/valveatlas-datasheet-cryogenic-gate-globe-valve.pdf\" target=\"_blank\" rel=\"noopener\">T\u00e9l\u00e9charger la fiche technique (PDF)<\/a><\/div><\/div><figure class=\"vx-intro-media vx-intro-ph\"><div><b>BS 6364<\/b><span>Cryogenic Gate and Globe Valves<\/span><\/div><\/figure><\/section>\n<h2 class=\"vx-h2\">Aper\u00e7u<\/h2><p>On gate valves, a vent hole in the wedge or body prevents liquid trapped between wedge and body from building up pressure. Globe valves are preferred on cryogenic lines that need flow regulation and tight shutoff. The valves must be installed with the stem vertical or pointing upward within a specified angle range; otherwise the gas column inside the bonnet does not form (see <a href=\"\/2026\/07\/25\/cryogenic-valve-installation-mistakes\/\">cryogenic valve installation mistakes<\/a>).<\/p>\n<h2 class=\"vx-h2\">Sp\u00e9cifications techniques<\/h2><div class=\"vx-table-wrap\"><table class=\"vx-table vx-spec\"><tbody><tr><th scope=\"row\">Taper<\/th><td>Gate (OS&amp;Y), globe; extended bonnet<\/td><\/tr><tr><th scope=\"row\">Temperature<\/th><td>Down to \u2212196 \u00b0C (\u2212321 \u00b0F)<\/td><\/tr><tr><th scope=\"row\">Mat\u00e9riels<\/th><td>CF8M, CF3M, F316, F316L<\/td><\/tr><tr><th scope=\"row\">Connexions terminales<\/th><td>Flanged, butt-weld, socket-weld<\/td><\/tr><tr><th scope=\"row\">Essai<\/th><td>Routine tests at ambient temperature; low-temperature test to BS 6364 (type test or on request)<\/td><\/tr><\/tbody><\/table><\/div>\n<h2 class=\"vx-h2\">Caract\u00e9ristiques principales<\/h2><ul class=\"vx-check\"><li>Vented wedge prevents pressure build-up in the cavity<\/li><li>Correct installation angle for the gas column<\/li><li>Austenitic stainless steel body<\/li><\/ul>\n<h2 class=\"vx-h2\">Documentation et tests<\/h2><p>Dans le cadre de projets industriels, la documentation technique est aussi importante que la vanne elle-m\u00eame. Nous confirmons la certification et le p\u00e9rim\u00e8tre des tests pour chaque \u00e9l\u00e9ment d\u00e8s l&#039;\u00e9tablissement du devis.<\/p><ul class=\"vx-check\"><li><strong>EN 10204 3.1 certificats de mat\u00e9riaux<\/strong> pour les pi\u00e8ces sous pression et en contact avec le fluide, tra\u00e7abilit\u00e9 par num\u00e9ro de coul\u00e9e<\/li><li><strong>EN 10204 3.2<\/strong> avec inspection par un tiers, sur demande<\/li><li><strong>Rapports d&#039;essais de pression<\/strong> essais de coque, de si\u00e8ge et, le cas \u00e9ch\u00e9ant, de gaz, conformes aux normes API 598 ou EN 12266-1<\/li><li><strong>Certificats d&#039;essai au feu<\/strong> (API 607 \/ ISO 10497) pour les conceptions test\u00e9es en mati\u00e8re de r\u00e9sistance au feu<\/li><li><strong>Rapports PMI<\/strong> pour les mat\u00e9riaux en alliage et en acier inoxydable<\/li><li><strong>Rapports d&#039;inspection dimensionnelle, visuelle et de rev\u00eatement<\/strong><\/li><li><strong>D\u00e9claration CE PDSE 2014\/68\/UE<\/strong> pour les \u00e9quipements relevant de son champ d&#039;application<\/li><li><strong>D\u00e9claration de conformit\u00e9 NACE MR0175 \/ ISO 15156<\/strong> pour service acide (H\u2082S)<\/li><\/ul>\n<h2 class=\"vx-h2\">Fiche technique<\/h2><ul class=\"vx-dl-list\"><li><a href=\"\/wp-content\/uploads\/2026\/09\/valveatlas-datasheet-cryogenic-gate-globe-valve.pdf\" target=\"_blank\" rel=\"noopener\"><span class=\"vx-pdf\">PDF<\/span><span class=\"vx-dl-t\">Cryogenic Gate and Globe Valves: technical datasheet<\/span><span class=\"vx-dl-m\">PDF \u00b7 Anglais \u00b7 2\u20133 pages<\/span><\/a><\/li><\/ul>\n<section class=\"vx-faq\"><h2 class=\"vx-h2\">Foire aux questions<\/h2><details class=\"vx-faq-item\"><summary>At what angle should a cryogenic valve be installed?<\/summary><div class=\"vx-faq-a\"><p>So that an insulating gas column can form inside the extended bonnet, the stem is installed vertical or pointing upward, up to a specified angle from vertical. Horizontal or downward-pointing installation can cause the packing to freeze; confirm the permissible angle with the manufacturer.<\/p><\/div><\/details><\/section>\n<h2 class=\"vx-h2\">Produits associ\u00e9s<\/h2><div class=\"vx-grid\"><a class=\"vx-card vx-card-media\" href=\"\/cryogenic-valves-lng\/cryogenic-ball-valve\/\"><div class=\"vx-card-img vx-card-ph\"><span>BS 6364<\/span><\/div><div class=\"vx-card-body\"><h3>Cryogenic Ball Valve<\/h3><p>Floating and trunnion mounted; extended bonnet, cavity relief, down to \u2212196 \u00b0C (\u2212321 \u00b0F).<\/p><span class=\"vx-more\">Voir les d\u00e9tails<\/span><\/div><\/a><\/div>\n<section class=\"vx-cta\"><div><h2>Request a quote: Cryogenic Gate and Globe Valves<\/h2><p>Partagez votre liste de vannes, votre fiche technique ou le cahier des charges de votre projet. Nous examinons les normes, les mat\u00e9riaux et la documentation ligne par ligne et vous soumettons une offre d\u00e9taill\u00e9e, toute d\u00e9rogation au cahier des charges \u00e9tant mentionn\u00e9e par \u00e9crit.<\/p><\/div><div class=\"vx-cta-actions\"><a class=\"vx-btn\" href=\"\/contact\/\">Demander un devis<\/a><a class=\"vx-cta-link\" href=\"mailto:info@valve-atlas.com\">info@valve-atlas.com<\/a><a class=\"vx-cta-link\" href=\"tel:+16475537109\">+1 (647) 553-7109<\/a><\/div><\/section><\/div>","protected":false},"excerpt":{"rendered":"<p>Home\/Industrial Valves\/Cryogenic Valves\/Cryogenic Gate and Globe Valves Cryogenic Valves Cryogenic gate and globe valves are used for isolation and flow regulation in LNG and industrial gas plants. An extended bonnet and austenitic stainless steel suitable for low temperatures are their key features; low-temperature testing to BS 6364 is performed as a type test or on&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":44055,"menu_order":25,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"iawp_total_views":0,"footnotes":""},"class_list":["post-44361","page","type-page","status-publish","hentry","description-off"],"acf":[],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44361","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=44361"}],"version-history":[{"count":0,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44361\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/44055"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=44361"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}