{"id":41837,"date":"2026-04-23T04:40:00","date_gmt":"2026-04-23T04:40:00","guid":{"rendered":"https:\/\/valve-atlas.com\/grooved-ball-valves-montreal\/"},"modified":"2026-04-26T01:06:23","modified_gmt":"2026-04-26T01:06:23","slug":"grooved-ball-valves-montreal","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/grooved-ball-valves-montreal\/","title":{"rendered":"Grooved Ball Valves Montreal | UL\/FM Grooved-End Brass Ball Valves for Fire Protection | Valve-Atlas"},"content":{"rendered":"<style>\ndiv.va-loc { font-family: Outfit, -apple-system, sans-serif !important; max-width: 1200px !important; margin: 32px auto !important; padding: 0 24px !important; box-sizing: border-box; }\ndiv.va-loc h2 { border-bottom: 3px solid #0B5ED7 !important; padding-bottom: 8px !important; margin-top: 48px !important; margin-bottom: 20px !important; color: #021228 !important; font-size: 32px !important; }\ndiv.va-loc h3 { color: #021228 !important; margin-top: 32px !important; margin-bottom: 12px !important; font-size: 22px !important; }\ndiv.va-loc p { color: rgba(2,18,40,0.82) !important; line-height: 1.7 !important; margin-bottom: 16px !important; font-size: 17px !important; }\ndiv.va-loc ul { padding-left: 24px !important; margin: 16px 0 24px !important; }\ndiv.va-loc ul li { color: rgba(2,18,40,0.82) !important; line-height: 1.8 !important; margin-bottom: 8px !important; list-style: disc !important; font-size: 17px !important; }\ndiv.va-loc strong { color: #021228 !important; }\ndiv.va-loc a { color: #0B5ED7 !important; text-decoration: underline !important; }\ndiv.va-loc a:hover { color: #021228 !important; }\ndiv.va-loc table { border-collapse: collapse; width: 100%; margin: 24px 0; background: white; border: 1px solid #E2E8F0; border-radius: 8px; overflow: hidden; }\ndiv.va-loc table th { background: #021228; color: white; padding: 12px 16px; text-align: left; font-weight: 600; }\ndiv.va-loc table td { padding: 12px 16px; border-top: 1px solid #E2E8F0; color: rgba(2,18,40,0.82); }\ndiv.va-loc table tr:nth-child(even) td { background: #F8FAFC; }\ndiv.va-loc .va-regions { background: #F8FAFC !important; border: 1px solid #E2E8F0 !important; border-radius: 12px !important; padding: 24px 28px !important; margin: 32px 0 !important; }\ndiv.va-loc .va-regions h3 { margin-top: 0 !important; color: #021228 !important; }\ndiv.va-loc .va-regions ul { list-style: none !important; padding: 0 !important; display: grid !important; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)) !important; gap: 8px !important; }\ndiv.va-loc .va-regions ul li { list-style: none !important; margin: 0 !important; }\ndiv.va-loc .va-regions a { display: block !important; padding: 10px 14px !important; border: 1px solid #E2E8F0 !important; border-radius: 8px !important; background: white !important; color: #0B5ED7 !important; text-decoration: none !important; text-align: center !important; font-weight: 500 !important; }\ndiv.va-loc .va-regions a:hover { background: #0B5ED7 !important; color: white !important; }\n<\/style>\n<div class=\"va-loc\" style=\"max-width:1200px;margin:32px auto;padding:0 24px;font-family:Outfit,-apple-system,sans-serif;box-sizing:border-box;\">\n<h2 class=\"wp-block-heading\">Grooved Ball Valves Montreal: UL Listed and FM Approved Grooved-End Brass Ball Valves for NFPA 13 Sprinkler, Standpipe and Fire Pump Test Header Applications<\/h2>\n<p>ValveAtlas supplies UL Listed and FM Approved grooved-end ball valves (UVBG-050, UVBG-065, UVBG-080, UVBG-100, UVBG-150 and UVBG-200) in DN50 through DN200 (2&#8243; through 8&#8243;) with bronze or ductile iron body, hard-chrome plated brass ball, PTFE seats and lever or gear-operator to fire protection contractors and mechanical subs across Montreal. 300 psi working pressure. Full NFPA 13 compliance and Service de securite incendie de Montreal (SIM) acceptance under CCQ Chapitre Batiment and CNB 2020.<\/p>\n<p>Technical reference for Montreal sprinkler contractors and fire pump installers at Montreal-Trudeau (YUL), Bombardier Dorval, Place Ville Marie and McGill University. Grooved-end ball valve is the preferred isolation valve for fire pump test header, sprinkler branch isolation and small-line standpipe drain where full-port flow and bubble-tight shutoff are required. Faster installation than flanged ball valves with matching performance.<\/p>\n<h2 class=\"wp-block-heading\">UNIVAL UVBG product range for Montreal projects<\/h2>\n<p>UVBG-050 through UVBG-200 covers 2&#8243; through 8&#8243; grooved ends per AWWA C606 grooving dimensions. Body is ASTM B584 cast bronze (small sizes) or ASTM A536 ductile iron (large sizes) with red epoxy coating. Ball is hard-chrome plated brass with full-port bore. Seats are reinforced PTFE for bubble-tight shutoff. Lever handle on sizes 2&#8243;-4&#8243;; gear operator on 6&#8243; and 8&#8243;.<\/p>\n<h2 class=\"wp-block-heading\">Why Montreal contractors choose ValveAtlas grooved ball valves<\/h2>\n<p><strong>UL 842 and FM 1160 dual listing.<\/strong> UVBG carries UL 842 (Valves for Flammable Fluids, grooved-end variant for fire protection) and FM 1160 (Ball Valves for Fire Protection Service) listing.<\/p>\n<p><strong>Full-port hard-chrome plated brass ball.<\/strong> No flow restriction and bubble-tight shutoff. Chrome plating protects against pitting corrosion in galvanized pipe systems.<\/p>\n<p><strong>Grooved ends per AWWA C606.<\/strong> Matches Victaulic, Shurjoint and Anvil grooved couplings on the same main. Faster installation than flanged, especially on 6&#8243; and 8&#8243; where overhead clearance is limited.<\/p>\n<h2 class=\"wp-block-heading\">Competitor substitution for Montreal projects<\/h2>\n<p>Victaulic Series 75\/76 grooved ball valve, Shurjoint B76 and NIBCO T-585 grooved ball valve all substitute one-for-one with UVBG at matching size and operator type. Same UL 842 and FM 1160 listing. Factory submittal available for Service de securite incendie de Montreal (SIM) acceptance.<\/p>\n<h2 class=\"wp-block-heading\">Related Montreal products<\/h2>\n<p>See also: <a href=\"\/butterfly-valves-montreal\/\">Butterfly valves Montreal<\/a>, <a href=\"\/grooved-check-valves-montreal\/\">Grooved check valves Montreal<\/a>, <a href=\"\/coupling-fittings\/\">Grooved couplings<\/a>, <a href=\"\/fire-pumps-montreal\/\">Fire pumps Montreal<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">Contact ValveAtlas for Montreal grooved ball valves quotation<\/h2>\n<p>Email UVBG quotation requests and Victaulic\/Shurjoint\/NIBCO substitution submittals for Service de securite incendie de Montreal (SIM) approval to <a href=\"mailto:info@valve-atlas.com\">info@valve-atlas.com<\/a>.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Grooved Ball Valves Montreal: UL Listed and FM Approved Grooved-End Brass Ball Valves for NFPA 13 Sprinkler, Standpipe and Fire Pump Test Header Applications ValveAtlas supplies UL Listed and FM Approved grooved-end ball valves (UVBG-050, UVBG-065, UVBG-080, UVBG-100, UVBG-150 and UVBG-200) in DN50 through DN200 (2&#8243; through 8&#8243;) with bronze or ductile iron body, hard-chrome&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","iawp_total_views":0,"footnotes":""},"class_list":["post-41837","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=41837"}],"version-history":[{"count":5,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41837\/revisions"}],"predecessor-version":[{"id":42442,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41837\/revisions\/42442"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=41837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}