{"id":41787,"date":"2026-04-23T04:35:33","date_gmt":"2026-04-23T04:35:33","guid":{"rendered":"https:\/\/valve-atlas.com\/angle-hose-valves-montreal\/"},"modified":"2026-04-26T01:06:23","modified_gmt":"2026-04-26T01:06:23","slug":"angle-hose-valves-montreal","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/angle-hose-valves-montreal\/","title":{"rendered":"Angle Hose Valves Montreal | UL 668\/FM 1210\/NFPA 14 | Valve-Atlas"},"content":{"rendered":"<style>\ndiv.va-loc { font-family: Outfit, -apple-system, sans-serif !important; max-width: 1200px !important; margin: 32px auto !important; padding: 0 24px !important; box-sizing: border-box; }\ndiv.va-loc h2 { border-bottom: 3px solid #0B5ED7 !important; padding-bottom: 8px !important; margin-top: 48px !important; margin-bottom: 20px !important; color: #021228 !important; font-size: 32px !important; }\ndiv.va-loc h3 { color: #021228 !important; margin-top: 32px !important; margin-bottom: 12px !important; font-size: 22px !important; }\ndiv.va-loc p { color: rgba(2,18,40,0.82) !important; line-height: 1.7 !important; margin-bottom: 16px !important; font-size: 17px !important; }\ndiv.va-loc ul { padding-left: 24px !important; margin: 16px 0 24px !important; }\ndiv.va-loc ul li { color: rgba(2,18,40,0.82) !important; line-height: 1.8 !important; margin-bottom: 8px !important; list-style: disc !important; font-size: 17px !important; }\ndiv.va-loc strong { color: #021228 !important; }\ndiv.va-loc a { color: #0B5ED7 !important; text-decoration: underline !important; }\ndiv.va-loc a:hover { color: #021228 !important; }\ndiv.va-loc table { border-collapse: collapse; width: 100%; margin: 24px 0; background: white; border: 1px solid #E2E8F0; border-radius: 8px; overflow: hidden; }\ndiv.va-loc table th { background: #021228; color: white; padding: 12px 16px; text-align: left; font-weight: 600; }\ndiv.va-loc table td { padding: 12px 16px; border-top: 1px solid #E2E8F0; color: rgba(2,18,40,0.82); }\ndiv.va-loc table tr:nth-child(even) td { background: #F8FAFC; }\ndiv.va-loc .va-regions { background: #F8FAFC !important; border: 1px solid #E2E8F0 !important; border-radius: 12px !important; padding: 24px 28px !important; margin: 32px 0 !important; }\ndiv.va-loc .va-regions h3 { margin-top: 0 !important; color: #021228 !important; }\ndiv.va-loc .va-regions ul { list-style: none !important; padding: 0 !important; display: grid !important; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)) !important; gap: 8px !important; }\ndiv.va-loc .va-regions ul li { list-style: none !important; margin: 0 !important; }\ndiv.va-loc .va-regions a { display: block !important; padding: 10px 14px !important; border: 1px solid #E2E8F0 !important; border-radius: 8px !important; background: white !important; color: #0B5ED7 !important; text-decoration: none !important; text-align: center !important; font-weight: 500 !important; }\ndiv.va-loc .va-regions a:hover { background: #0B5ED7 !important; color: white !important; }\n<\/style>\n<div class=\"va-loc\" style=\"max-width:1200px;margin:32px auto;padding:0 24px;font-family:Outfit,-apple-system,sans-serif;box-sizing:border-box;\">\n<h2 class=\"wp-block-heading\">Angle Hose Valves and Landing Valves Montreal: UL 668 Listed, FM 1210 Approved Class I\/II\/III Standpipe Hose Valves for NFPA 14 Section 5.4 Compliant Installations<\/h2>\n<p>ValveAtlas supplies UL Listed, FM Approved and LPCB Listed angle hose valves, pressure-reducing landing valves and Class I\/II\/III standpipe hose connections (UVLV-ANG-1.5, UVLV-ANG-2.5, UVLV-PRV-1.5, UVLV-PRV-2.5, UVLV-SWIVEL, UVLV-AUTO, UVLV-CAB and UVLV-BS-2.5) with red brass or forged bronze body, NH or BS 336 instantaneous coupling, hand-wheel operator and break-off cap chain to fire protection contractors and mechanical subs across Montreal. Every UNIVAL UV- line item carries UL or FM listing at minimum. Full submittal package for Service de securite incendie de Montreal (SIM) approval.<\/p>\n<p>This is the technical reference for Montreal specifying engineers selecting angle hose valves packages for Montreal-Trudeau (YUL), Bombardier Dorval, Place Ville Marie, Tour de la Bourse and McGill University, governed by CCQ Chapitre Batiment + CNB 2020. Stock UVLV-ANG-1.5 and UVLV-ANG-2.5 with standard NH thread ship 2 to 3 weeks.<\/p>\n<h2 class=\"wp-block-heading\">UNIVAL UVLV product range for Montreal projects<\/h2>\n<p>UVLV-ANG-1.5 is a 1.5&#8243; angle hose valve with UL 668 listing for fire cabinet Class II occupant-use hose stations. UVLV-ANG-2.5 is the 2.5&#8243; fire-service-use variant with UL 668 and FM 1210 dual listing for Class I\/III standpipe outlets. UVLV-PRV-1.5 and UVLV-PRV-2.5 are pressure-reducing landing valves with field-adjustable 25-175 psi outlet pressure, UL 668 and FM 1210 listed with UL 1468 pressure-regulating valve approval. UVLV-SWIVEL is a swivel 2.5&#8243; angle valve for roof manifold and apparatus hose angle flexibility. UVLV-AUTO includes automatic drip drain for exterior exposed outlets. UVLV-BS-2.5 carries LPCB LPS 1054 and BS 5041-1 listing for UK dry riser per BS 5306-1.<\/p>\n<h2 class=\"wp-block-heading\">Why Montreal contractors choose ValveAtlas angle hose valves<\/h2>\n<p><strong>UL 668 and FM 1210 dual listing for AHJ acceptance.<\/strong> Every UNIVAL UVLV carries UL 668 and FM 1210 listing with forged bronze or red brass body. Pressure-reducing variants are additionally listed under UL 1468 and FM 1210.<\/p>\n<p><strong>Pressure-reducing landing valves per NFPA 14 Section 7.2.3.<\/strong> UVLV-PRV-1.5 and UVLV-PRV-2.5 are field-adjustable, factory-set to design pressure per riser schedule.<\/p>\n<p><strong>Red brass or forged bronze body with break-off cap chain.<\/strong> UVLV bodies are cast red brass (ASTM B584) or forged bronze (ASTM B283) standard. Each valve ships with a matching cap on a break-away chain per NFPA 14 6.4.5.<\/p>\n<h2 class=\"wp-block-heading\">Competitor substitution for Montreal angle hose valves projects<\/h2>\n<p>Potter Roemer Fig 4065, Croker 6000 series, Guardian 2500 PRV, Elkhart Brass and Giacomini angle landing valves all substitute one-for-one with matching UVLV SKUs at identical inlet\/outlet configuration and UL 668\/FM 1210\/UL 1468 listing. Factory submittal package available for Service de securite incendie de Montreal (SIM) approval.<\/p>\n<h2 class=\"wp-block-heading\">Related Montreal fire protection products<\/h2>\n<p>See also: <a href=\"\/fire-pumps-montreal\/\">Fire pumps Montreal<\/a>, <a href=\"\/fdc-montreal\/\">FDC Montreal<\/a>, <a href=\"\/check-valves-montreal\/\">Check valves Montreal<\/a>, <a href=\"\/gate-valves-montreal\/\">Gate valves Montreal<\/a>, <a href=\"\/hydrants-montreal\/\">Fire hydrants Montreal<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">Contact ValveAtlas for Montreal angle hose valves quotation<\/h2>\n<p>For angle hose valves quotations and substitution submittals for Service de securite incendie de Montreal (SIM) approval, email project details to <a href=\"mailto:info@valve-atlas.com\">info@valve-atlas.com<\/a>. Same-day response on urgent orders.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Angle Hose Valves and Landing Valves Montreal: UL 668 Listed, FM 1210 Approved Class I\/II\/III Standpipe Hose Valves for NFPA 14 Section 5.4 Compliant Installations ValveAtlas supplies UL Listed, FM Approved and LPCB Listed angle hose valves, pressure-reducing landing valves and Class I\/II\/III standpipe hose connections (UVLV-ANG-1.5, UVLV-ANG-2.5, UVLV-PRV-1.5, UVLV-PRV-2.5, UVLV-SWIVEL, UVLV-AUTO, UVLV-CAB and UVLV-BS-2.5)&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","iawp_total_views":0,"footnotes":""},"class_list":["post-41787","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41787","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=41787"}],"version-history":[{"count":5,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41787\/revisions"}],"predecessor-version":[{"id":42462,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41787\/revisions\/42462"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=41787"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}