{"id":41743,"date":"2026-04-22T00:14:32","date_gmt":"2026-04-22T00:14:32","guid":{"rendered":"https:\/\/valve-atlas.com\/raccord-pompier-montreal\/"},"modified":"2026-06-24T04:29:04","modified_gmt":"2026-06-24T04:29:04","slug":"raccord-pompier-montreal","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/raccord-pompier-montreal\/","title":{"rendered":"Raccords Pompier Montr\u00e9al"},"content":{"rendered":"<style>\ndiv.va-loc { font-family: Outfit, -apple-system, sans-serif !important; max-width: 1200px !important; margin: 32px auto !important; padding: 0 24px !important; box-sizing: border-box; }\ndiv.va-loc h2 { border-bottom: 3px solid #0B5ED7 !important; padding-bottom: 8px !important; margin-top: 48px !important; margin-bottom: 20px !important; color: #021228 !important; font-size: 32px !important; }\ndiv.va-loc h3 { color: #021228 !important; margin-top: 32px !important; margin-bottom: 12px !important; font-size: 22px !important; }\ndiv.va-loc p { color: rgba(2,18,40,0.82) !important; line-height: 1.7 !important; margin-bottom: 16px !important; font-size: 17px !important; }\ndiv.va-loc ul { padding-left: 24px !important; margin: 16px 0 24px !important; }\ndiv.va-loc ul li { color: rgba(2,18,40,0.82) !important; line-height: 1.8 !important; margin-bottom: 8px !important; list-style: disc !important; font-size: 17px !important; }\ndiv.va-loc strong { color: #021228 !important; }\ndiv.va-loc a { color: #0B5ED7 !important; text-decoration: underline !important; }\ndiv.va-loc a:hover { color: #021228 !important; }\ndiv.va-loc table { border-collapse: collapse; width: 100%; margin: 24px 0; background: white; border: 1px solid #E2E8F0; border-radius: 8px; overflow: hidden; }\ndiv.va-loc table th { background: #021228; color: white; padding: 12px 16px; text-align: left; font-weight: 600; }\ndiv.va-loc table td { padding: 12px 16px; border-top: 1px solid #E2E8F0; color: rgba(2,18,40,0.82); }\ndiv.va-loc table tr:nth-child(even) td { background: #F8FAFC; }\ndiv.va-loc .va-regions { background: #F8FAFC !important; border: 1px solid #E2E8F0 !important; border-radius: 12px !important; padding: 24px 28px !important; margin: 32px 0 !important; }\ndiv.va-loc .va-regions h3 { margin-top: 0 !important; color: #021228 !important; }\ndiv.va-loc .va-regions ul { list-style: none !important; padding: 0 !important; display: grid !important; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)) !important; gap: 8px !important; }\ndiv.va-loc .va-regions ul li { list-style: none !important; margin: 0 !important; }\ndiv.va-loc .va-regions a { display: block !important; padding: 10px 14px !important; border: 1px solid #E2E8F0 !important; border-radius: 8px !important; background: white !important; color: #0B5ED7 !important; text-decoration: none !important; text-align: center !important; font-weight: 500 !important; }\ndiv.va-loc .va-regions a:hover { background: #0B5ED7 !important; color: white !important; }\n<\/style>\n<div class=\"va-loc\" style=\"max-width:1200px;margin:32px auto;padding:0 24px;font-family:Outfit,-apple-system,sans-serif;box-sizing:border-box;\">\n<h2 class=\"wp-block-heading\">Raccords Pompier Montr\u00e9al: Raccords Pompier (Siamese) UL 405 Listed et FM 1510 Approved 2-Voies, 3-Voies et Storz pour CCQ Chapitre Batiment, NFPA 14 Section 8.17 et CAN\/ULC-S543 Installations Colonne Montante, Gicleurs et Collecteur Essai Pompe Incendie<\/h2>\n<p>ValveAtlas fournit des raccords pompier UL 405 Listed (Fire Department Connections pour Service Protection Incendie) et FM Class 1510 Approved incluant configurations 2-voies et 3-voies murales\/exposees, Storz 4 po et 5 po raccord rapide, pi\u00e9destal autoportant, affleurant trottoir, collecteur toit et collecteur essai pompe incendie aux entrepreneurs protection incendie, sous-traitants m\u00e9caniques, promoteurs haute tour et propri\u00e9taires industriels \u00e0 travers Montr\u00e9al, Laval, Longueuil, Brossard, Terrebonne, Ville de Qu\u00e9bec, Gatineau, Sherbrooke et Trois-Rivi\u00e8res. Livraison m\u00e9tropolitaine, corps laiton coul\u00e9 ou chrome brut, clapet v\u00e9rifi\u00e9 int\u00e9gral pour pr\u00e9vention retour eau, cha\u00eenes bouchon et paquets soumission SIM pour raccords pompier Montr\u00e9al.<\/p>\n<p>Cette page est la r\u00e9f\u00e9rence technique pour ingenieurs prescripteurs, ingenieurs protection incendie, consultants mecaniques et services eau municipaux Montreal selectionnant packages raccord pompier pour installations aire piste a\u00e9roport Montr\u00e9al-Trudeau (YUL), a\u00e9roport de Mirabel et a\u00e9roport Qu\u00e9bec Jean-Lesage (YQB), sites industriels Bombardier Saint-Laurent, Pratt Whitney Longueuil, Rolls-Royce Lachine, GE Aviation Bromont et Alcoa Becancour, haute tours Place Ville Marie, Tour de la Bourse, 1000 de La Gauchetiere, Tour Deloitte et Place Bonaventure, campus Universite de Montreal, McGill, UQAM, Concordia, Polytechnique et HEC et centres de donnees Bell MTL1, Cologix MTL1 et MTL3, Vantage MTL1 et OVH Beauharnois, r\u00e9gie par Code de Construction du Qu\u00e9bec (CCQ) 2015 Chapitre Batiment et NFPA 14 Section 8.17, NFPA 13 articles 8.17 et CAN\/ULC-S543.<\/p>\n<h2 class=\"wp-block-heading\">Gamme raccords pompier pour projets Montr\u00e9al<\/h2>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>Taper<\/th>\n<th>R\u00e9f\u00e9rence Unival<\/th>\n<th>Entr\u00e9e de configuration<\/th>\n<th>Taille sortie<\/th>\n<th>Certifications<\/th>\n<th>Application typique de Montr\u00e9al<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Raccord pompier mural 2-voies<\/strong><\/td>\n<td>UVFDC-2W-2.5<\/td>\n<td>2 x 2,5 po NH femelle pivotant<\/td>\n<td>Sortie 4 po NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Entr\u00e9e colonne montante\/gicleurs commerciale standard mur ext\u00e9rieur<\/td>\n<\/tr>\n<tr>\n<td><strong>Raccord pompier mural 3 voies haute tour<\/strong><\/td>\n<td>UVFDC-3W-2.5<\/td>\n<td>3 x 2,5 po NH femelle pivotant<\/td>\n<td>Sortie 6 po NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Colonne montante combin\u00e9e haute tour\/gicleurs pour syst\u00e8me Classe I\/III<\/td>\n<\/tr>\n<tr>\n<td><strong>Raccord Storz 4 po mural<\/strong><\/td>\n<td>UVFDC-STZ4-W<\/td>\n<td>Storz 4 po raccord rapide<\/td>\n<td>Sortie 4 po NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Raccord pompe raccord rapide pour alimentation service incendie grand volume<\/td>\n<\/tr>\n<tr>\n<td><strong>Raccord Storz 5 po mural<\/strong><\/td>\n<td>UVFDC-STZ5-W<\/td>\n<td>Storz 5 po raccord rapide<\/td>\n<td>Sortie 5 po NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Storz grand diam\u00e8tre pour alimentation pompier grand volume<\/td>\n<\/tr>\n<tr>\n<td><strong>Raccord pompier autoportant 2 voies<\/strong><\/td>\n<td>UVFDC-2W-FS<\/td>\n<td>2 x 2,5 po NH avec pi\u00e9destal<\/td>\n<td>Sortie 4 po NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Raccord pompier autoportant ou mur impossible, avec support socle<\/td>\n<\/tr>\n<tr>\n<td><strong>Raccord Storz autoportant<\/strong><\/td>\n<td>UVFDC-STZ-FS<\/td>\n<td>Storz 4 po ou 5 po avec socle<\/td>\n<td>Sortie 4 ou 5 NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Raccord Storz autoportant avec socle, d\u00e9ploiement rapide<\/td>\n<\/tr>\n<tr>\n<td><strong>Raccord pompier affleurant trottoir<\/strong><\/td>\n<td>UVFDC-C\u00d4T\u00c9-2W<\/td>\n<td>2 x 2,5 po NH affleurant avec couvercle \u00e0 charni\u00e8re<\/td>\n<td>Sortie 4 po NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Raccord affleurant trottoir pour fa\u00e7ade \u00e9troite, plaque charni\u00e8re spec SIM<\/td>\n<\/tr>\n<tr>\n<td><strong>Raccord Storz affleurant trottoir<\/strong><\/td>\n<td>UVFDC-SIDE-STZ<\/td>\n<td>Storz 4 po affleurant avec couvercle \u00e0 charni\u00e8re<\/td>\n<td>Sortie 4 po NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Raccord affleurant trottoir avec Storz pour haute tour fa\u00e7ade etroite<\/td>\n<\/tr>\n<tr>\n<td><strong>Collecteur essai pompe incendie<\/strong><\/td>\n<td>TEST UVFDC-4<\/td>\n<td>4 x 2,5 po NH sorties essai refoulement<\/td>\n<td>Entr\u00e9e 6 po NPT depuis pompe<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Collecteur essai pompe incendie pour essai d\u00e9bit pompe NFPA 25 Chapitre 8<\/td>\n<\/tr>\n<tr>\n<td><strong>Raccord pompier toit<\/strong><\/td>\n<td>UVFDC-TOITURE 2W<\/td>\n<td>2 x 2,5 po NH sur collecteur toit<\/td>\n<td>Sortie 4 po NPT<\/td>\n<td>UL 405, FM 1510<\/td>\n<td>Raccord pompe niveau toit pour alimentation auxiliaire haute tour<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">Pourquoi entrepreneurs Montr\u00e9al choisir ValveAtlas raccords pompier<\/h2>\n<p><strong>Double certification UL 405 et FM 1510 pour acceptation SIM.<\/strong> Chaque raccord pompier Unival est homologu\u00e9 UL 405 (Fire Department Connections pour Service Protection Incendie) et FM Class 1510 Approved. SIM accepte raccords certifie avec soumission d&#039;usine, lettre conforme CCQ Chapitre Batiment et documentation NFPA 14 Section 8.17. UL 405 certifie corps raccord, clapets v\u00e9rifie internes, entr\u00e9es pivotantes, bouchon et dispositions drain.<\/p>\n<p><strong>Clapet v\u00e9rifier int\u00e9grale pour pr\u00e9vention retour eau.<\/strong> UVFDC-2W et UVFDC-3W incluent des clapets v\u00e9rifie les ressorts internes sur chaque entr\u00e9e qui empechent retour eau depuis colonne montante ou syst\u00e8me gicleurs par entr\u00e9e inutilis\u00e9e. La section 8.17 de la NFPA 14 exige que chaque entr\u00e9e de raccord de pompier ait un clapet v\u00e9rifi\u00e9. Clapet Unival en bronze avec ressort inox, cote 300 psi service, 600 psi hydrostatique.<\/p>\n<p><strong>Finition laiton ou chrome brut avec chaines bouchon.<\/strong> Les corps UVFDC sont en laiton rouge coul\u00e9 (ASTM B584) standard, chrome brut ou chrome poli sur demande. Chaque entr\u00e9e vient avec bouchon bronze ou couvercle sur cha\u00eene (rupture de cha\u00eene sur raccords trottoir) pour empecher les d\u00e9bris d&#039;intrusion. Plaque identification coul\u00e9e dans corps avec \u201c RACCORD POMPIER \u2013 COLONNE MONTANTE \u201d, \u201c GICLEURS AUTO \u201d ou \u201c GICLEURS AUTO ET COLONNE MONTANTE \u201d selon NFPA 14\/13 Section 8.17.1.<\/p>\n<p><strong>Entr\u00e9es pivotantes avec filetage compatible SIM.<\/strong> Les entr\u00e9es UVFDC-2W et UVFDC-3W sont femelles pivotantes avec 2.5 po NH (National Hose) filetage Qu\u00e9bec pour entr\u00e9es 2-voies et 3-voies standard. entr\u00e9es Storz 4 po et 5 po raccord rapide optionnelles pour appareils SIM. Forme filetage sp\u00e9cifi\u00e9e par commande usine pour raccords correspondants boyau appareils service incendie locaux. Le pivot permet une rotation \u00e0 360 degr\u00e9s pour un engagement boyau service incendie \u00e0 tout angle.<\/p>\n<p><strong>Clapet v\u00e9rifier int\u00e9gral avec corps raccord pompier.<\/strong> NFPA 14 Section 8.17 et NFPA 13 Section 8.17 exigeant clapet verifie certifie entre raccord pompier et syst\u00e8me colonne montante ou gicleurs. Le corps UVFDC comprend un clapet principal int\u00e9gral en aval des clapets d&#039;entr\u00e9e pour empecher sortie eau syst\u00e8me par raccord pompier lors essai ou inspection. Certification UL 405 combine couvre-clapets entr\u00e9e et clapet principal.<\/p>\n<p><strong>Substitution directe pour Potter Roemer, Croker, Guardian, Elkhart et NEWCO.<\/strong> La s\u00e9rie Unival UVFDC est certifi\u00e9e UL 405\/FM 1510 \u00e9quivalente \u00e0 Potter Roemer Fig 5062, Croker 6700, Guardian GA4000, Elkhart S-300 et NEWCO NC-FDC. SIM accepte les substitutions certifi\u00e9es \u00e9quivalentes avec approbation ing\u00e9nieur responsable et package soumission d&#039;usine comprenant dessin clapet interne, certificat UL et v\u00e9rification classification pression.<\/p>\n<h2 class=\"wp-block-heading\">Code d&#039;acceptation et certification pour Montr\u00e9al<\/h2>\n<p><strong>Code de Construction du Qu\u00e9bec (CCQ) 2015 Chapitre B\u00e2timent.<\/strong> Code de Construction du Qu\u00e9bec (CCQ) 2015 Chapitre Batiment r\u00e9f\u00e9rence NFPA 14 Section 8.17 (raccord pompier colonne montante) et NFPA 13 Section 8.17 (raccord pompier gicleurs) pour placement raccord pompier syst\u00e8me combine. Le raccord pompier doit \u00eatre situ\u00e9 pas moins de 450 mm (18 po) et pas plus de 1200 mm (48 po) au-dessus du sol selon NFPA 14 Section 8.17.3 et doit \u00eatre visible et accessible au service incendie dans les 30 m (100 pi) d&#039;une voie incendie ou d&#039;acc\u00e8s pav\u00e9 selon NFPA 14 Section 8.17.4.<\/p>\n<p><strong>NFPA 14 Section 8.17 raccord pompe colonne montante.<\/strong> NFPA 14 Section 8.17 exige une entr\u00e9e 2.5 po par 250 gpm de d\u00e9bit colonne montante, minimum 2 entr\u00e9es pour colonnes montantes Classe I et III, avec clapet v\u00e9rifier certifie int\u00e9gral entre raccord pompier et montant colonne montante. Raccord Storz permis avec approbation SIM. UVFDC-2W rencontre exigence minimale ; UVFDC-3W fournit une capacit\u00e9 suppl\u00e9mentaire pour les syst\u00e8mes haute tour Classe I\/III.<\/p>\n<p><strong>NFPA 13 Section 8.17 raccord pompier gicleurs.<\/strong> NFPA 13 Section 8.17 exige le raccord de pompier pour syst\u00e8mes gicleurs avec demande d&#039;eau 250 gpm ou plus, avec entr\u00e9es minimum 2 voies 2,5 po NH et clapet v\u00e9rifier int\u00e9gral entre le raccord pompier et montant gicleurs. UVFDC-2W et UVFDC-SIDE-2W satisfont \u00e0 l&#039;exigence NFPA 13 pour raccord pompier accessible ext\u00e9rieurement en amont clapet v\u00e9rifier montant gicleurs.<\/p>\n<p><strong>Raccords UL 405 Pompier.<\/strong> UL 405 regit corps raccord pompier, clapets v\u00e9rifie, entr\u00e9es pivotantes, bouchons\/couvercles et drain de construction. S\u00e9rie UVFDC rencontre UL 405 avec corps bronze, clapet bronze ressort, entr\u00e9e NH ou Storz avec certification jauge filetage et cha\u00eene rupture. UL 405 requis pour toutes applications NFPA 13\/14.<\/p>\n<p><strong>Approbation FM 1510.<\/strong> FM 1510 regit vannes service incendie et equipement associ\u00e9 incluant raccords pompier. S\u00e9rie Unival UVFDC porte approbation FM Class 1510 pour colonne montante, gicleurs et syst\u00e8mes combin\u00e9s selon les directives FM Data Sheet 4-0 sur alimentation eau.<\/p>\n<p><strong>Carte SIM d&#039;acceptation.<\/strong> Inspection Service de s\u00e9curit\u00e9 incendie de Montr\u00e9al (SIM), R\u00e9gie du b\u00e2timent du Qu\u00e9bec (RBQ) et Ville de Montr\u00e9al Service de l&#039;eau r\u00e9f\u00e9rence Code de Construction du Qu\u00e9bec (CCQ) 2015 Chapitre B\u00e2timent, NFPA 14 Section 8.17, NFPA 13 Section 8.17 et CAN\/ULC-S543 et certification du fabricant. Soumission d&#039;usine avec certificats UL 405\/FM 1510, lettre conforme NFPA 14\/13 Section 8.17 et rapport essai pression hydrostatique requis pour signature. Identification signe raccord pompier selon NFPA 14 Section 8.17.1 requis \u00e0 l&#039;installation.<\/p>\n<h2 class=\"wp-block-heading\">Substitution Potter Roemer, Croker, Guardian, Elkhart et NEWCO pour projets Montr\u00e9al<\/h2>\n<p><strong>Potter Roemer Fig 5062 raccord pompier mural 2 voies.<\/strong> Substitut UVFDC-2W-2.5 a entr\u00e9es 2 x 2.5 po NH correspondantes, sortie 4 po NPT et configuration clapet v\u00e9rifier int\u00e9grale. M\u00eame certification UL 405\/FM 1510, corps laiton rouge coul\u00e9e, clapet bronze et bouchons cha\u00eene rupture. Substitution raccord pompier combine standard Montr\u00e9al colonne montante\/gicleurs avec forfait soumission d&#039;usine.<\/p>\n<p><strong>Croker 6700 raccord pompier mural 2 voies.<\/strong> Substituer UVFDC-2W-2.5 a configuration entr\u00e9e, taille sortie et position clapet v\u00e9rifier correspondantes. M\u00eame certification UL 405 et forme filetage bouchon op\u00e9ration pentagone FDNY\/SIM. La substitution n\u00e9cessite l&#039;approbation de l&#039;ing\u00e9nieur responsable et le dessin soumission d&#039;usine.<\/p>\n<p><strong>Guardian GA4000 raccord mural Storz.<\/strong> Substituer UVFDC-STZ4-W ou UVFDC-STZ5-W \u00e0 taille Storz 4 po ou 5 po et diam\u00e8tre sortie NPT correspondants. M\u00eame certification UL 405 avec clapet int\u00e9gral. Compatibilit\u00e9 filetage Storz avec appareils SIM v\u00e9rifi\u00e9e par commande usine.<\/p>\n<p><strong>Elkhart S-300 raccord pompier autoportant.<\/strong> Remplacer UVFDC-2W-FS ou UVFDC-STZ-FS par nombre d&#039;entr\u00e9es, forme filetage et hauteur du socle correspondant. Certification Meme UL 405\/FM 1510 avec socle de support. Remplacer Elkhart par Unival sur installations ou trottoir impossible et raccord pompier socle autoportant sp\u00e9cifique.<\/p>\n<p><strong>Zurn Wilkins 375 et Dixon DIX raccords pompier.<\/strong> Remplacez UVFDC-2W-2.5, UVFDC-3W-2.5 ou UVFDC-SIDE-2W par une configuration correspondante. M\u00eame certification UL 405 avec clapets v\u00e9rifie les int\u00e9graux. Version affleurante trottoir UVFDC-SIDE-2W avec couvercle charniere et clapet contre-poids pour fa\u00e7ade \u00e9troite.<\/p>\n<p><strong>NEWCO NC-FDC raccord pompier moissonneuse-batteuse.<\/strong> Remplacer UVFDC-2W-2.5 ou UVFDC-3W-2.5 par une configuration correspondante. M\u00eame certification UL 405\/FM 1510, corps laiton coule et clapet v\u00e9rifier int\u00e9gral. Etiquette colonne montante\/gicleurs combiner selon NFPA 14 Section 8.17.1.<\/p>\n<h2 class=\"wp-block-heading\">Sc\u00e9narios d&#039;installation pour raccords pompier Montr\u00e9al<\/h2>\n<p><strong>Protection incendie aire piste et a\u00e9rogare a\u00e9roport Montr\u00e9al-Trudeau (YUL), a\u00e9roport de Mirabel et a\u00e9roport Qu\u00e9bec Jean-Lesage (YQB).<\/strong> Protection incendie a\u00e9rogare et aire piste avec UVFDC-2W-2.5 a entr\u00e9e batiment aerogare, UVFDC-STZ4-W Storz 4 po a approche voie incendie pour alimentation pompier SIM et UVFDC-TEST-4 collecteurs essai pompe incendie sur poste pompe incendie aire piste. Conforme NFPA 14 Section 8.17 avec clapet int\u00e9gral et approbation FM 1510.<\/p>\n<p><strong>Protection incendie industrielle et s\u00e9curit\u00e9 proc\u00e8dent Bombardier Saint-Laurent, Pratt Whitney Longueuil, Rolls-Royce Lachine, GE Aviation Bromont et Alcoa B\u00e9cancour.<\/strong> Site industriel avec UVFDC-3W-2.5 raccord 3-voies pour entr\u00e9e gicleurs\/colonne montante grande demande combin\u00e9e, UVFDC-2W-FS raccord pompe autoportant a voie incendie ou mur impossible, et UVFDC-TEST-4 collecteur essai sur refoulement pompe incendie pour essais d\u00e9bit pompe NFPA 25 annuels. Conforme site FM Global avec directives alimentation eau FM Data Sheet 4-0.<\/p>\n<p><strong>Colonne montante haute tour et raccord pompier gicleurs Place Ville Marie, Tour de la Bourse, 1000 de La Gaucheti\u00e8re, Tour Deloitte et Place Bonaventure.<\/strong> Colonne montante Classe I\/III haute tour avec raccord 3 voies UVFDC-3W-2.5 sur fa\u00e7ade rue pour capacit\u00e9 entr\u00e9e augment\u00e9e selon NFPA 14 Section 8.17, raccord affleurant trottoir UVFDC-SIDE-2W pour b\u00e2timents fa\u00e7ade \u00e9troite, et raccord toit UVFDC-ROOF-2W pour alimentation auxiliaire sur b\u00e2timents plus de 128 m (420 pi) (selon NFPA 14 pour Classe II multizone). Storz 5 po UVFDC-STZ5-W a zone acces camion pompe pour alimentation grand volume.<\/p>\n<p><strong>Campus Universitaire de Montr\u00e9al, McGill, UQAM, Concordia, Polytechnique et HEC et centre de donn\u00e9es Bell MTL1, Cologix MTL1 et MTL3, Vantage MTL1 et OVH Beauharnois.<\/strong> Campus et centre de donn\u00e9es avec UVFDC-2W-2.5 \u00e0 chaque entr\u00e9e du b\u00e2timent selon NFPA 13 Section 8.17, UVFDC-TEST-4 collecteur essai pompe incendie \u00e0 poste pompe incendie centrale et entr\u00e9es Storz UVFDC-STZ4-W a approche voie incendie principale pour appareils SIM. Int\u00e9gration avec vannes indicatrices poteau existant, pompe incendie et boucle borne.<\/p>\n<p><strong>Salle pompe incendie et collecteur essai.<\/strong> UVFDC-TEST-4 collecteur essai 4-voies 2.5 po NH sur refoulement pompe incendie avec prises manom\u00e8tre pitot individuelles pour essai debit pompe incendie annuel NFPA 25 Chapitre 8. Cote 300 psi service, monte exterieur salle pompe sur mur exterieur pour refoulement sur atmosph\u00e8re securitaire. Satisfait arrangement essai pompe NFPA 20 Chapitre 4.<\/p>\n<h2 class=\"wp-block-heading\">Produits connexes pour package complet vanne protection incendie Montr\u00e9al<\/h2>\n<p><strong>Pompes en feu.<\/strong> Pompes incendie UVFP-HSC, UVFP-ES et UVFP-VIL alimentant raccord pompier\/gicleurs\/colonne montante selon NFPA 20. Voir <a href=\"https:\/\/valve-atlas.com\/fire-pumps-montreal\/\">Pompes Incendie Montr\u00e9al<\/a>.<\/p>\n<p><strong>Clapets.<\/strong> Clapets fermeture silencieuse UVC-NR et clapets \u00e0 battant UVC-SW pour refoulement pompe incendie et alimentation gicleurs entre raccord pompe et syst\u00e8me selon NFPA 13\/14 Section 8.17. Voir <a href=\"https:\/\/valve-atlas.com\/clapets-montreal\/\">Clapets Montr\u00e9al<\/a>.<\/p>\n<p><strong>Bornes incendie.<\/strong> Bornes incendie UVH-3DRY barillet sec alimentant canalisation principale service incendie priv\u00e9 qui alimente boucle raccord pompier selon NFPA 24 Chapitre 7. Voir <a href=\"https:\/\/valve-atlas.com\/bornes-incendie-montreal\/\">Bornes Incendie Montr\u00e9al<\/a>.<\/p>\n<p><strong>Vannes indicatrices poteau.<\/strong> Vannes indicatrices poteau UVPIV-BG comme isolement sur branche alimentation raccord pompe selon NFPA 24. Voir <a href=\"https:\/\/valve-atlas.com\/post-indicator-valves-montreal\/\">Vannes Indicatrices Poteau Montr\u00e9al<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">Foire aux questions (Montr\u00e9al)<\/h2>\n<p><strong>Unique est-il accept\u00e9 par SIM?<\/strong> Oui. La s\u00e9rie Unival UVFDC est r\u00e9pertori\u00e9e UL 405 et approuv\u00e9e FM 1510. SIM accepte raccords pompier certifie avec soumission d&#039;usine, lettre conforme CCQ Chapitre Batiment, documentation NFPA 14 Section 8.17 et rapport essai hydrostatique. Signe d&#039;identification selon NFPA 14 Section 8.17.1 requis sur l&#039;installation.<\/p>\n<p><strong>2 voies ou 3 voies pour Montr\u00e9al ?<\/strong> 2 voies (UVFDC-2W-2.5) satisfait \u00e0 l&#039;exigence minimale NFPA 14 pour colonnes montantes Classe I\/III jusqu&#039;\u00e0 500 gpm et syst\u00e8mes gicleurs NFPA 13. 3 voies (UVFDC-3W-2.5) fournit une capacit\u00e9 additionnelle pour syst\u00e8mes haute tour plus de 500 gpm ou colonne montante\/gicleurs combiner ou ing\u00e9nieur specifie entr\u00e9e suppl\u00e9mentaire selon NFPA 14 Article 8.17.2.<\/p>\n<p><strong>Storz contre les filets r\u00f4tis ?<\/strong> Les filets (UVFDC-2W, UVFDC-3W) utilisent un filetage 2,5 po NH (National Hose) Qu\u00e9bec pour entr\u00e9es 2 voies et 3 voies standard, compatible avec boyau filet\u00e9 SIM existant. Storz (UVFDC-STZ4-W, UVFDC-STZ5-W) utilise un raccord rapide 4 po ou 5 po avec raccord sans genre, permet une connexion rapide sans filetage mais exige cle Storz SIM. entr\u00e9es Storz 4 po et 5 po raccord rapide optionnelles pour appareils SIM.<\/p>\n<p><strong>Mural vs autoportant vs affleurant trottoir ?<\/strong> Mural (UVFDC-2W, UVFDC-3W) est standard pour les b\u00e2timents avec fa\u00e7ade murale ext\u00e9rieure. Autoportant (UVFDC-2W-FS) sur socle est requis ou mur impossible (stationnements, b\u00e2timents en retrait, cours int\u00e9rieurs). Affleurant trottoir (UVFDC-SIDE-2W) est requis pour fa\u00e7ade \u00e9troite ou mur et socle impraticables, avec couvercle charniere pour finition trottoir correspondante.<\/p>\n<p><strong>Quelle est la classification de la pression ?<\/strong> UVFDC standard est pression service 300 psi avec essai hydrostatique 600 psi selon UL 405. Option haute pression UVFDC-HP cote 400 psi service pour boucles haute pression industrielles. Clapet v\u00e9rifie interne cote meme classe pression que corps.<\/p>\n<p><strong>Quel est le d\u00e9lai de livraison \u00e0 Montr\u00e9al?<\/strong> UVFDC-2W-2.5 en stock avec filetage NH standard livre 2 \u00e0 3 semaines. Formes filetage personnalis\u00e9es (Qu\u00e9bec, NYC, Boston, Storz) assembl\u00e9es en usine 3 \u00e0 5 semaines. Autoportant UVFDC-2W-FS avec socle 4 \u00e0 6 semaines. Affleurant trottoir UVFDC-SIDE-2W 4 \u00e0 6 semaines. Transport m\u00e9tropolitain QG Toronto 3 \u00e0 5 jours ouvrables.<\/p>\n<p><strong>Comment remplacer Potter Roemer, Croker, Guardian, Elkhart et NEWCO sur projet Montr\u00e9al?<\/strong> Soumettre lettre de substitution avec certificats Unival UL 405\/FM 1510, dessin soumission d&#039;usine affichant configuration clapet v\u00e9rifier interne, v\u00e9rification jauge filetage et conformit\u00e9 NFPA 14\/13 Section 8.17. Agr\u00e9ment ing\u00e9nieur responsable costume; SIM accepte les substitutions certifi\u00e9es \u00e9quivalentes.<\/p>\n<h2 class=\"wp-block-heading\">Contacter ValveAtlas pour soumission raccord pompier Montr\u00e9al<\/h2>\n<p>Pour soumissions raccord pompe, soumissions de substitution Potter Roemer Fig 5062, Croker 6700, Guardian GA4000, Elkhart S-300 et NEWCO NC-FDC pour approbation SIM, ou packages raccord pompe NFPA 14\/13 Section 8.17 avec clapet int\u00e9gral UL 405\/FM 1510 certifie pour projets aire piste a\u00e9roport Montr\u00e9al-Trudeau (YUL), a\u00e9roport de Mirabel et a\u00e9roport Qu\u00e9bec Jean-Lesage (YQB), haute tour Montr\u00e9al, site industriel, campus universitaire, centre de donn\u00e9es ou collecteur essai pompe incendie, envoyez \u00e9l\u00e9vation architecturale du projet, planification montant colonne montante\/gicleurs et calcul debit incendie a burakpadr@gmail.com ou utilisez le formulaire de contact. R\u00e9ponse m\u00eame jour sur commandes urgentes Montr\u00e9al.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Raccords Pompier Montreal: Raccords Pompier (Siamese) UL 405 Listed et FM 1510 Approved 2-Voies, 3-Voies et Storz pour CCQ Chapitre Batiment, NFPA 14 Section 8.17 et CAN\/ULC-S543 Installations Colonne Montante, Gicleurs et Collecteur Essai Pompe Incendie ValveAtlas fournit des raccords pompier UL 405 Listed (Fire Department Connections pour Service Protection Incendie) et FM Class 1510&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"iawp_total_views":0,"footnotes":""},"class_list":["post-41743","page","type-page","status-publish","hentry","description-off"],"acf":[],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41743","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=41743"}],"version-history":[{"count":6,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41743\/revisions"}],"predecessor-version":[{"id":43871,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41743\/revisions\/43871"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=41743"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}