{"id":41723,"date":"2026-04-21T23:17:46","date_gmt":"2026-04-21T23:17:46","guid":{"rendered":"https:\/\/valve-atlas.com\/gate-valves-new-york\/"},"modified":"2026-04-26T01:06:24","modified_gmt":"2026-04-26T01:06:24","slug":"gate-valves-new-york","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/gate-valves-new-york\/","title":{"rendered":"Gate Valves New York | UL 262\/FM 1120 FDNY NFPA 13\/14 | Valve-Atlas"},"content":{"rendered":"<style>\ndiv.va-loc { font-family: Outfit, -apple-system, sans-serif !important; max-width: 1200px !important; margin: 32px auto !important; padding: 0 24px !important; box-sizing: border-box; }\ndiv.va-loc h2 { border-bottom: 3px solid #0B5ED7 !important; padding-bottom: 8px !important; margin-top: 48px !important; margin-bottom: 20px !important; color: #021228 !important; font-size: 32px !important; }\ndiv.va-loc h3 { color: #021228 !important; margin-top: 32px !important; margin-bottom: 12px !important; font-size: 22px !important; }\ndiv.va-loc p { color: rgba(2,18,40,0.82) !important; line-height: 1.7 !important; margin-bottom: 16px !important; font-size: 17px !important; }\ndiv.va-loc ul { padding-left: 24px !important; margin: 16px 0 24px !important; }\ndiv.va-loc ul li { color: rgba(2,18,40,0.82) !important; line-height: 1.8 !important; margin-bottom: 8px !important; list-style: disc !important; font-size: 17px !important; }\ndiv.va-loc strong { color: #021228 !important; }\ndiv.va-loc a { color: #0B5ED7 !important; text-decoration: underline !important; }\ndiv.va-loc a:hover { color: #021228 !important; }\ndiv.va-loc table { border-collapse: collapse; width: 100%; margin: 24px 0; background: white; border: 1px solid #E2E8F0; border-radius: 8px; overflow: hidden; }\ndiv.va-loc table th { background: #021228; color: white; padding: 12px 16px; text-align: left; font-weight: 600; }\ndiv.va-loc table td { padding: 12px 16px; border-top: 1px solid #E2E8F0; color: rgba(2,18,40,0.82); }\ndiv.va-loc table tr:nth-child(even) td { background: #F8FAFC; }\ndiv.va-loc .va-regions { background: #F8FAFC !important; border: 1px solid #E2E8F0 !important; border-radius: 12px !important; padding: 24px 28px !important; margin: 32px 0 !important; }\ndiv.va-loc .va-regions h3 { margin-top: 0 !important; color: #021228 !important; }\ndiv.va-loc .va-regions ul { list-style: none !important; padding: 0 !important; display: grid !important; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)) !important; gap: 8px !important; }\ndiv.va-loc .va-regions ul li { list-style: none !important; margin: 0 !important; }\ndiv.va-loc .va-regions a { display: block !important; padding: 10px 14px !important; border: 1px solid #E2E8F0 !important; border-radius: 8px !important; background: white !important; color: #0B5ED7 !important; text-decoration: none !important; text-align: center !important; font-weight: 500 !important; }\ndiv.va-loc .va-regions a:hover { background: #0B5ED7 !important; color: white !important; }\n<\/style>\n<div class=\"va-loc\" style=\"max-width:1200px;margin:32px auto;padding:0 24px;font-family:Outfit,-apple-system,sans-serif;box-sizing:border-box;\">\n<h2 class=\"wp-block-heading\">Gate Valves New York: UL 262 Listed and FM 1120 Approved OS&#038;Y Rising Stem and NRS Non-Rising Stem Gate Valves for NYC BC Chapter 9, FDNY TM 2, NFPA 13 Chapter 16 and UL 262 Private Fire Service Mains, Sprinkler Control and Standpipe Isolation<\/h2>\n<p>ValveAtlas supplies UL 262 Listed, FM Class 1120 Approved and UL 262\/FM 1120 approved gate valves including OS&#038;Y rising stem, NRS non-rising stem, resilient wedge, flanged and grooved-end configurations to fire protection contractors, mechanical consultants, civil underground trades and general contractors across Manhattan, Brooklyn, Queens, Bronx, Staten Island, Jersey City, Newark, Hoboken, Long Island and Westchester. Metro delivery, factory-coated ductile-iron bodies, stainless steel stems, EPDM resilient wedges for NYC metro winter and NYC BC Chapter 9 submittal packages for FDNY.<\/p>\n<p>This page is the technical reference for New York specifying engineers, sprinkler contractors, mechanical installers and civil underground contractors selecting gate valve packages for JFK, LaGuardia (LGA), Newark Liberty (EWR) and Teterboro (TEB) fire mains, NewYork-Presbyterian, Mount Sinai, NYU Langone, Memorial Sloan Kettering, Bellevue and Montefiore campus loops, Columbia, NYU, Fordham, CUNY, Cornell Tech Roosevelt Island and Rockefeller University campuses, Equinix NY1 through NY12, Digital Realty 111 8th Avenue, Sabey 375 Pearl and CoreSite NY1\/NY2 data centers and any NFPA 13 Chapter 16 or FDNY Technical Manual 2, NFPA 13 Chapter 16, NFPA 14 Chapter 6 fire protection control valve application, governed by NYC Building Code Chapter 9 (2022 edition) and FDNY Technical Manual 2, NFPA 13 Chapter 16, NFPA 14 Chapter 6.<\/p>\n<h2 class=\"wp-block-heading\">Gate valve range for New York fire protection projects<\/h2>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>Type<\/th>\n<th>UNIVAL SKU<\/th>\n<th>Size<\/th>\n<th>Max working pressure<\/th>\n<th>Listings<\/th>\n<th>Typical New York application<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>OS&#038;Y rising stem<\/strong><\/td>\n<td>UVG-OSY-4F<\/td>\n<td>4 inch \/ DN100 flanged<\/td>\n<td>175 psi<\/td>\n<td>UL 262, FM 1120<\/td>\n<td>Indoor sprinkler riser control per NFPA 13 Section 16.9.3<\/td>\n<\/tr>\n<tr>\n<td><strong>OS&#038;Y rising stem<\/strong><\/td>\n<td>UVG-OSY-6F<\/td>\n<td>6 inch \/ DN150 flanged<\/td>\n<td>175 psi<\/td>\n<td>UL 262, FM 1120<\/td>\n<td>Fire pump suction and discharge per NFPA 20 Chapter 4.16<\/td>\n<\/tr>\n<tr>\n<td><strong>OS&#038;Y rising stem<\/strong><\/td>\n<td>UVG-OSY-8F<\/td>\n<td>8 inch \/ DN200 flanged<\/td>\n<td>175 psi<\/td>\n<td>UL 262, FM 1120<\/td>\n<td>Standpipe isolation and incoming main sprinkler control<\/td>\n<\/tr>\n<tr>\n<td><strong>OS&#038;Y grooved-end<\/strong><\/td>\n<td>UVG-OSY-6G<\/td>\n<td>6 inch grooved<\/td>\n<td>300 psi<\/td>\n<td>UL 262, FM 1120<\/td>\n<td>Grooved piping system control valve, high-rise standpipe<\/td>\n<\/tr>\n<tr>\n<td><strong>NRS non-rising stem<\/strong><\/td>\n<td>UVG-NRS-6<\/td>\n<td>6 inch \/ DN150 MJ<\/td>\n<td>250 psi<\/td>\n<td>UL 262, FM 1120, AWWA C509<\/td>\n<td>Underground buried main with indicator post or hand wheel<\/td>\n<\/tr>\n<tr>\n<td><strong>NRS resilient wedge<\/strong><\/td>\n<td>UVG-NRS-8-RW<\/td>\n<td>8 inch \/ DN200 MJ<\/td>\n<td>250 psi<\/td>\n<td>UL 262, FM 1120, AWWA C515<\/td>\n<td>Municipal fire main connection and hydrant branch<\/td>\n<\/tr>\n<tr>\n<td><strong>High-pressure OS&#038;Y<\/strong><\/td>\n<td>UVG-OSY-6F-HP<\/td>\n<td>6 inch flanged<\/td>\n<td>300 psi<\/td>\n<td>UL 262, FM 1120<\/td>\n<td>High-rise standpipe lower zone, fire pump high-pressure discharge<\/td>\n<\/tr>\n<tr>\n<td><strong>Tamper switch kit<\/strong><\/td>\n<td>UVG-TS<\/td>\n<td>All sizes<\/td>\n<td>24 VDC<\/td>\n<td>UL 753<\/td>\n<td>Supervisory switch per NFPA 72 Section 17.16<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">Why New York contractors choose ValveAtlas gate valves<\/h2>\n<p><strong>UL 262 and FM 1120 dual listing for FDNY acceptance.<\/strong> Every UNIVAL gate valve is UL 262 Listed (gate valves for fire-protection service) and FM Class 1120 Approved. FDNY accepts listed gate valves with factory submittal, NYC BC Chapter 9 compliance letter and NFPA 13 Chapter 16 sprinkler control valve documentation.<\/p>\n<p><strong>OS&#038;Y rising stem for indoor sprinkler control.<\/strong> NFPA 13 Section 16.9.3 requires sprinkler system control valves be OS&#038;Y, post indicator, listed butterfly or listed equivalent. UVG-OSY-4F, UVG-OSY-6F and UVG-OSY-8F cover 4 to 10 inch flanged OS&#038;Y range for sprinkler riser, fire pump, standpipe and incoming main isolation in New York commercial, institutional and industrial buildings.<\/p>\n<p><strong>NRS non-rising stem for buried fire service main.<\/strong> UVG-NRS-6 and UVG-NRS-8-RW 6 to 12 inch non-rising stem gate valves with mechanical joint end connections for direct bury on fire service mains feeding hydrants, post indicator valves and building incoming sprinkler mains. AWWA C509 (metal-seated) and AWWA C515 (resilient-seated) compliant with UL 262, FM 1120, AWWA C509 and C515, NSF 61.<\/p>\n<p><strong>Ductile iron body with fusion-bonded epoxy.<\/strong> UVG bodies are ductile iron ASTM A536 Grade 65-45-12 with factory-applied fusion-bonded epoxy coating per AWWA C550, rated for indoor dry-sidewall mount and direct-bury underground service. Stainless steel stem, EPDM or buna-N resilient seat and bronze operating nut rated for 175 psi \/ 200 psi \/ 250 psi \/ 300 psi working pressure.<\/p>\n<p><strong>Frost-protected for NYC metro winter.<\/strong> UVG-NRS buried gate valves sized for New York metro frost line (42 inches (1.07 m) bury depth per NYC DEP standards). Operating stem and hand wheel extension accommodate bury depth with reliable OPEN\/SHUT operation through winter freeze\/thaw cycles.<\/p>\n<p><strong>Tamper-supervised with UL 753 switch.<\/strong> UVG-TS tamper switch kit UL 753 Listed, 24 VDC, compatible with FDNY-approved fire alarm control panels per NFPA 72 Section 17.16.2 supervisory signal requirements. Factory-wired to OS&#038;Y handwheel or NRS operator for FDNY fire alarm acceptance.<\/p>\n<p><strong>Direct substitution for Kennedy, Clow, Mueller, M&#038;H and AVK.<\/strong> UNIVAL UVG-OSY and UVG-NRS are UL 262\/FM 1120 listed equivalent to Kennedy 4500, Clow 2639 and F-6100, Mueller A-2361, M&#038;H 3067. FDNY accepts listed equivalent substitutions with engineer-of-record approval and factory submittal package.<\/p>\n<h2 class=\"wp-block-heading\">Code and listing acceptance for New York<\/h2>\n<p><strong>NYC Building Code Chapter 9 (2022 edition).<\/strong> NYC Building Code Chapter 9 (2022 edition) references NFPA 13 and FDNY Technical Manual 2, NFPA 13 Chapter 16, NFPA 14 Chapter 6 for fire sprinkler and standpipe system control valves. Gate valve selection must satisfy Section 903.3.5 sprinkler water supply and Section 905 standpipe isolation. UVG UNIVAL ships NYC BC Chapter 9 compliant.<\/p>\n<p><strong>NFPA 13 Chapter 16 sprinkler system valves.<\/strong> NFPA 13 Chapter 16 governs sprinkler system control valves. Section 16.9.3 (indicating-type valves) requires OS&#038;Y, post indicator, listed butterfly or listed equivalent. UVG-OSY series satisfies this requirement. Section 16.9.5 requires all control valves be supervised per NFPA 72.<\/p>\n<p><strong>NFPA 20 fire pump installation.<\/strong> NFPA 20 Chapter 4.16 requires OS&#038;Y gate valve on fire pump suction and discharge with listed tamper supervision. UVG-OSY-6F and UVG-OSY-8F with UVG-TS tamper switch satisfy fire pump isolation and supervision requirements.<\/p>\n<p><strong>NFPA 14 standpipe control valves.<\/strong> NFPA 14 Chapter 6 requires listed OS&#038;Y or PIV isolation valves on standpipe incoming main and zone isolation. UVG-OSY-6F and UVG-OSY-8F with supervision satisfy NFPA 14 for New York high-rise residential, commercial and mixed-use standpipe installations.<\/p>\n<p><strong>FDNY acceptance.<\/strong> FDNY (Fire Department City of New York) and NYC Department of Buildings inspection references NYC Building Code Chapter 9 (2022 edition), FDNY Technical Manual 2, NFPA 13 Chapter 16, NFPA 14 Chapter 6 and manufacturer listing. Factory submittal with UL\/FM\/ULC certificates, tamper supervision acceptance test per NFPA 72 and hydrostatic test per AWWA C600 required for sign-off.<\/p>\n<h2 class=\"wp-block-heading\">Kennedy, Clow, Mueller, M&#038;H and AVK substitution for New York projects<\/h2>\n<p><strong>Kennedy 4500 and 8068 OS&#038;Y gate valve.<\/strong> Substitute UVG-OSY-4F, UVG-OSY-6F or UVG-OSY-8F at matching size and flange drilling (ANSI B16.1 Class 125\/250). Same UL 262\/FM 1120 listing, ductile iron body with fusion-bonded epoxy, resilient or metal-seated wedge. New York standard brand substitution with factory submittal package.<\/p>\n<p><strong>Clow 2639 and F-6100 gate valve.<\/strong> Substitute UVG-OSY-4F, UVG-OSY-6F or UVG-OSY-8F at matching duty. Same OS&#038;Y rising stem with indicator hand wheel for New York sprinkler riser and fire pump isolation.<\/p>\n<p><strong>Mueller A-2361 resilient wedge gate.<\/strong> Substitute UVG-OSY or UVG-NRS series. Matching resilient wedge construction with UL 262 listing. Common FDNY-approved substitution for New York mechanical contractor work.<\/p>\n<p><strong>M&#038;H 3067 and RW129 gate valve.<\/strong> Substitute UVG-OSY-6F or UVG-OSY-8F at matching size and pressure rating. Same 175 psi (or 300 psi high-pressure) rating and AWWA C515 compliance.<\/p>\n<p><strong>AVK Series 06\/30 and 06\/80 resilient seated gate.<\/strong> Substitute UVG-OSY or UVG-NRS at matching configuration. Matching EPDM resilient seat, ductile iron body and UL\/FM listing.<\/p>\n<h2 class=\"wp-block-heading\">Installation scenarios for New York gate valves<\/h2>\n<p><strong>JFK, LaGuardia (LGA), Newark Liberty (EWR) and Teterboro (TEB) fire mains and airside sprinkler systems.<\/strong> Airside fire mains feeding terminals, cargo ramps and maintenance hangars with UVG-NRS-8-RW and UVG-NRS-10-RW at building isolation and zone branches. UVG-OSY-6F and UVG-OSY-8F at fire pump suction\/discharge and indoor standpipe isolation.<\/p>\n<p><strong>NewYork-Presbyterian, Mount Sinai, NYU Langone, Memorial Sloan Kettering, Bellevue and Montefiore campus sprinkler control.<\/strong> New York hospital campus sprinkler risers with UVG-OSY-4F, UVG-OSY-6F and UVG-OSY-8F at zone control, fire pump room and incoming main isolation. Tamper-supervised per NFPA 72 Section 17.16, monitored at central fire alarm command center.<\/p>\n<p><strong>Columbia, NYU, Fordham, CUNY, Cornell Tech Roosevelt Island and Rockefeller University campus standpipe and sprinkler.<\/strong> University dormitory, lecture hall, library and research building standpipe isolation and sprinkler control with UVG-OSY-4F and UVG-OSY-6F. FDNY acceptance with factory submittal.<\/p>\n<p><strong>Equinix NY1 through NY12, Digital Realty 111 8th Avenue, Sabey 375 Pearl and CoreSite NY1\/NY2 data center incoming sprinkler.<\/strong> Data center sprinkler incoming main with UVG-OSY-6F, pre-action panel isolation with UVG-OSY-4F, and clean agent room bypass isolation. Tamper-supervised for 24\/7 NOC monitoring.<\/p>\n<p><strong>High-rise residential and commercial standpipe.<\/strong> New York high-rise standpipe zone isolation with UVG-OSY-6F-HP 300 psi at lower zones and UVG-OSY-6F 175 psi at upper zones. NFPA 14 Chapter 6 compliant with factory-wired tamper supervision.<\/p>\n<h2 class=\"wp-block-heading\">Related products for complete New York fire protection valve package<\/h2>\n<p><strong>Butterfly valves.<\/strong> UVB-G310 grooved butterfly with integral tamper as listed butterfly alternative to OS&#038;Y gate for sprinkler control. See <a href=\"https:\/\/valve-atlas.com\/butterfly-valves-new-york\/\">Butterfly Valves New York<\/a>.<\/p>\n<p><strong>Check valves.<\/strong> UVC-NR silent-closure check valves for fire pump discharge and backflow prevention per NFPA 20. See <a href=\"https:\/\/valve-atlas.com\/check-valves-new-york\/\">Check Valves New York<\/a>.<\/p>\n<p><strong>Post indicator valves.<\/strong> UVPIV-6-PIVA for underground fire service main indicator post valves. See <a href=\"https:\/\/valve-atlas.com\/post-indicator-valves-new-york\/\">Post Indicator Valves New York<\/a>.<\/p>\n<p><strong>Fire pumps.<\/strong> UVFP-HSC, UVFP-ES and UVFP-VIL fire pumps with OS&#038;Y gate valve isolation per NFPA 20. See <a href=\"https:\/\/valve-atlas.com\/fire-pumps-new-york\/\">Fire Pumps New York<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">Frequently asked questions (New York)<\/h2>\n<p><strong>Is UNIVAL accepted by FDNY?<\/strong> Yes. UNIVAL gate valves are UL 262 Listed and FM 1120 Approved. FDNY accepts listed gate valves with factory submittal, NYC BC Chapter 9 compliance letter and NFPA 13 Chapter 16 documentation.<\/p>\n<p><strong>Do I need OS&#038;Y or butterfly on my sprinkler riser?<\/strong> Both are listed alternatives per NFPA 13 Section 16.9.3. OS&#038;Y provides visual OPEN\/SHUT indication via rising stem; listed grooved butterfly with integral tamper provides position indication via lever. New York common practice uses OS&#038;Y on fire pump room and main risers; grooved butterfly on zone isolation.<\/p>\n<p><strong>What working pressure do I need for high-rise standpipe?<\/strong> NFPA 14 requires 150 psi minimum at highest outlet with total system pressure often exceeding 250 psi in tall buildings. UVG-OSY-6F-HP 300 psi satisfies lower-zone high-rise standpipe isolation in New York tall buildings.<\/p>\n<p><strong>Resilient wedge vs metal-seated?<\/strong> AWWA C515 resilient wedge provides tighter seal, easier operation and longer service life for buried potable\/fire service applications. AWWA C509 metal-seated is legacy standard. UVG-NRS series defaults to C515 resilient wedge; C509 available on request.<\/p>\n<p><strong>What is the delivery time to New York?<\/strong> Stock UVG-OSY-4F, UVG-OSY-6F and UVG-OSY-8F ship 1 to 2 weeks. UVG-NRS buried mains ship 2 to 3 weeks. UVG-OSY-HP 300 psi high-pressure factory-built ships 3 to 4 weeks. Metro freight from Toronto HQ 2 to 3 business days.<\/p>\n<p><strong>How do I substitute Kennedy, Clow, Mueller, M&#038;H and AVK on a New York project?<\/strong> Submit substitution letter with UNIVAL UL 262\/FM 1120 certificates, factory submittal drawing and NFPA 13 Chapter 16 compliance. Engineer-of-record approval follows; FDNY accepts listed equivalent substitutions.<\/p>\n<h2 class=\"wp-block-heading\">Contact ValveAtlas for New York gate valve quotation<\/h2>\n<p>For gate valve quotations, Kennedy 4500, Clow 2639 and F-6100, Mueller A-2361, M&#038;H 3067 substitution submittals for FDNY approval, or NFPA 13\/14\/20 control valve packages with tamper supervision and frost protection for JFK, LaGuardia (LGA), Newark Liberty (EWR) and Teterboro (TEB) airside, New York hospital campus, university campus, data center or high-rise standpipe projects, email the project mechanical drawings, pipe size, pressure class and fire alarm panel matrix to burakpadr@gmail.com or use the contact form. Same-day response on NYC urgent orders.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Gate Valves New York: UL 262 Listed and FM 1120 Approved OS&#038;Y Rising Stem and NRS Non-Rising Stem Gate Valves for NYC BC Chapter 9, FDNY TM 2, NFPA 13 Chapter 16 and UL 262 Private Fire Service Mains, Sprinkler Control and Standpipe Isolation ValveAtlas supplies UL 262 Listed, FM Class 1120 Approved and UL&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"content-type":"","iawp_total_views":0,"footnotes":""},"class_list":["post-41723","page","type-page","status-publish","hentry","description-off"],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41723","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=41723"}],"version-history":[{"count":4,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41723\/revisions"}],"predecessor-version":[{"id":42481,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41723\/revisions\/42481"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=41723"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}