{"id":41659,"date":"2026-04-21T04:54:58","date_gmt":"2026-04-21T04:54:58","guid":{"rendered":"https:\/\/valve-atlas.com\/gate-valves-fire-protection\/"},"modified":"2026-05-11T04:41:41","modified_gmt":"2026-05-11T04:41:41","slug":"gate-valves-fire-protection","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/gate-valves-fire-protection\/","title":{"rendered":"Protection incendie des vannes \u00e0 guillotine"},"content":{"rendered":"<style>\ndiv.va-loc { font-family: Outfit, -apple-system, sans-serif !important; max-width: 1200px !important; margin: 32px auto !important; padding: 0 24px !important; box-sizing: border-box; }\ndiv.va-loc h2 { border-bottom: 3px solid #0B5ED7 !important; padding-bottom: 8px !important; margin-top: 48px !important; margin-bottom: 20px !important; color: #021228 !important; font-size: 32px !important; }\ndiv.va-loc h3 { color: #021228 !important; margin-top: 32px !important; margin-bottom: 12px !important; font-size: 22px !important; }\ndiv.va-loc p { color: rgba(2,18,40,0.82) !important; line-height: 1.7 !important; margin-bottom: 16px !important; font-size: 17px !important; }\ndiv.va-loc ul { padding-left: 24px !important; margin: 16px 0 24px !important; }\ndiv.va-loc ul li { color: rgba(2,18,40,0.82) !important; line-height: 1.8 !important; margin-bottom: 8px !important; list-style: disc !important; font-size: 17px !important; }\ndiv.va-loc strong { color: #021228 !important; }\ndiv.va-loc a { color: #0B5ED7 !important; text-decoration: underline !important; }\ndiv.va-loc a:hover { color: #021228 !important; }\ndiv.va-loc table { border-collapse: collapse; width: 100%; margin: 24px 0; background: white; border: 1px solid #E2E8F0; border-radius: 8px; overflow: hidden; }\ndiv.va-loc table th { background: #021228; color: white; padding: 12px 16px; text-align: left; font-weight: 600; }\ndiv.va-loc table td { padding: 12px 16px; border-top: 1px solid #E2E8F0; color: rgba(2,18,40,0.82); }\ndiv.va-loc table tr:nth-child(even) td { background: #F8FAFC; }\ndiv.va-loc .va-regions { background: #F8FAFC !important; border: 1px solid #E2E8F0 !important; border-radius: 12px !important; padding: 24px 28px !important; margin: 32px 0 !important; }\ndiv.va-loc .va-regions h3 { margin-top: 0 !important; color: #021228 !important; }\ndiv.va-loc .va-regions ul { list-style: none !important; padding: 0 !important; display: grid !important; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)) !important; gap: 8px !important; }\ndiv.va-loc .va-regions ul li { list-style: none !important; margin: 0 !important; }\ndiv.va-loc .va-regions a { display: block !important; padding: 10px 14px !important; border: 1px solid #E2E8F0 !important; border-radius: 8px !important; background: white !important; color: #0B5ED7 !important; text-decoration: none !important; text-align: center !important; font-weight: 500 !important; }\ndiv.va-loc .va-regions a:hover { background: #0B5ED7 !important; color: white !important; }\n<\/style>\n<div class=\"va-loc\" style=\"max-width:1200px;margin:32px auto;padding:0 24px;font-family:Outfit,-apple-system,sans-serif;box-sizing:border-box;\">\n<h2 class=\"wp-block-heading\">Vannes \u00e0 guillotine pour la protection incendie\u00a0: homologu\u00e9es UL, ULC et FM, mod\u00e8les UNIVAL UV0199 et UV0299.<\/h2>\n<p>ValveAtlas fournit des vannes \u00e0 guillotine UNIVAL UV0199 OS&amp;Y (\u00e0 vis ext\u00e9rieure et \u00e9trier) et UV0299 NRS (\u00e0 tige non montante) homologu\u00e9es UL, ULC et FM pour l&#039;isolation des colonnes montantes d&#039;extincteurs automatiques, l&#039;aspiration et le refoulement des pompes \u00e0 incendie, les raccordements aux conduites d&#039;eau souterraines, les ensembles d&#039;indicateurs de poteaux et le contr\u00f4le de zone des colonnes montantes sur des projets \u00e0 Toronto, Montr\u00e9al, New York, Boston et Londres.<\/p>\n<p>Cette page constitue la r\u00e9f\u00e9rence technique pour les ing\u00e9nieurs charg\u00e9s de la sp\u00e9cification, les entreprises EPC et les sous-traitants m\u00e9caniques qui s\u00e9lectionnent les vannes \u00e0 guillotine sur les syst\u00e8mes de protection incendie r\u00e9gis par les normes NFPA 13, NFPA 20, NFPA 24, BS EN 12845 et le document approuv\u00e9 B.<\/p>\n<h2 class=\"wp-block-heading\">Gamme de vannes \u00e0 guillotine UNIVAL<\/h2>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>UGS UNIVERSELLE<\/th>\n<th>Taper<\/th>\n<th>Connexion finale<\/th>\n<th>classe de pression<\/th>\n<th>Annonces<\/th>\n<th>Tailles<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>UV0199<\/strong><\/td>\n<td>Porte indicatrice OS&amp;Y (vis ext\u00e9rieure et \u00e9trier)<\/td>\n<td>\u00c0 brides ANSI 150 ou ANSI 300<\/td>\n<td>300 psi CWP<\/td>\n<td>UL, ULC, FM<\/td>\n<td>2\u2033 \u00e0 12\u2033<\/td>\n<\/tr>\n<tr>\n<td><strong>UV0299<\/strong><\/td>\n<td>Vanne NRS (\u00e0 tige non montante) avec \u00e9crou de man\u0153uvre<\/td>\n<td>Joint \u00e0 brides ou joint m\u00e9canique (MJ)<\/td>\n<td>300 psi CWP<\/td>\n<td>UL, ULC, FM<\/td>\n<td>2\u2033 \u00e0 12\u2033<\/td>\n<\/tr>\n<tr>\n<td><strong>UV0800-IP<\/strong><\/td>\n<td>indicateur de niveau sup\u00e9rieur de la vanne indicatrice de position (PIV)<\/td>\n<td>MJ ou \u00e0 bride, enterr\u00e9 avec tige verticale<\/td>\n<td>250 psi CWP<\/td>\n<td>UL, ULC, FM<\/td>\n<td>4\u2033 \u00e0 10\u2033<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">S\u00e9lection OS&amp;Y vs NRS vs PIV<\/h2>\n<p><strong>Porte OS&amp;Y (UV0199).<\/strong> Utilis\u00e9e lorsque la vanne est visible de l&#039;int\u00e9rieur du b\u00e2timent\u00a0: base de colonne montante d&#039;extincteurs automatiques, aspiration de pompe incendie, refoulement de pompe incendie, r\u00e9gulation de zone de colonne montante. La tige filet\u00e9e d\u00e9passe visiblement de l&#039;\u00e9trier lorsque la vanne est ouverte\u00a0; la position visible de la tige sert d&#039;indicateur. Un interrupteur anti-sabotage sur l&#039;\u00e9trier contr\u00f4le la position ouverte\/ferm\u00e9e.<\/p>\n<p><strong>Porte NRS (UV0299).<\/strong> Utilis\u00e9e lorsque la vanne est enterr\u00e9e ou situ\u00e9e dans un regard\u00a0: raccordements \u00e0 la conduite d\u2019eau souterraine, vanne d\u2019arr\u00eat principale du b\u00e2timent dans un regard. La tige ne d\u00e9passe pas\u00a0; l\u2019\u00e9crou de man\u0153uvre situ\u00e9 en haut est actionn\u00e9 par une cl\u00e9 en T. L\u2019indication est fournie par un indicateur de position (IP) situ\u00e9 hors sol ou par un dispositif de surveillance de la position de la vanne dans le regard.<\/p>\n<p><strong>PIV (UV0800-IP).<\/strong> Indicateur de niveau hors sol pour une vanne \u00e0 guillotine enterr\u00e9e NRS. Cet indicateur est constitu\u00e9 d&#039;un poteau en acier s&#039;\u00e9tendant de la vanne enterr\u00e9e jusqu&#039;\u00e0 une hauteur de 81 \u00e0 102 cm au-dessus du niveau du sol. Une fen\u00eatre d&#039;indication affiche \u201c\u00a0OUVERT\u00a0\u201d ou \u201c\u00a0FERM\u00c9\u00a0\u201d lorsque la vanne est actionn\u00e9e \u00e0 l&#039;aide de l&#039;\u00e9crou situ\u00e9 en haut du poteau. La norme NFPA 24, section 6.3, exige la pr\u00e9sence d&#039;un indicateur de niveau hors sol sur les raccordements aux conduites d&#039;eau souterraines alimentant les syst\u00e8mes de protection incendie, \u00e0 l&#039;endroit o\u00f9 la conduite d&#039;eau p\u00e9n\u00e8tre sur la propri\u00e9t\u00e9.<\/p>\n<h2 class=\"wp-block-heading\">Inscriptions et acceptation des codes<\/h2>\n<p><strong>UL 262.<\/strong> Les mod\u00e8les UV0199 et UV0299 sont homologu\u00e9s UL 262 (vannes \u00e0 guillotine pour la protection contre l&#039;incendie).<\/p>\n<p><strong>Homologations FM Classe 1110\/1120.<\/strong> Les num\u00e9ros UV0199 et UV0299 sont r\u00e9pertori\u00e9s pour les propri\u00e9t\u00e9s assur\u00e9es contre la gestion des risques d&#039;incendie. Les experts en gestion des risques d&#039;incendie, RSA, Aviva, Zurich, Allianz, AXA Commercial, Chubb, AIG, Travelers et Intact acceptent le certificat de gestion des risques d&#039;incendie.<\/p>\n<p><strong>Inscription ULC pour les projets canadiens.<\/strong> La norme CAN\/ULC-S543 couvre les r\u00e9f\u00e9rences des produits pour les projets canadiens NFPA 13.<\/p>\n<p><strong>Acceptation LPCB et Royaume-Uni.<\/strong> Reconnaissance de la norme BS EN 12845, section 15 (vannes), par \u00e9quivalence avec la norme LPS 1039. Les experts en assurance britanniques confirment l&#039;acceptation sp\u00e9cifique de cette norme par le LPCB.<\/p>\n<h2 class=\"wp-block-heading\">O\u00f9 sont install\u00e9es les vannes \u00e0 guillotine<\/h2>\n<p><strong>Base de la colonne montante du gicleur.<\/strong> UV0199 OS&amp;Y, install\u00e9 imm\u00e9diatement en amont de la vanne d&#039;alarme humide (UVW-1511-300), de la vanne de conduite s\u00e8che (UVD-2511-300) ou de la vanne de pr\u00e9action (UVPR-5311-300). Assure l&#039;isolation du syst\u00e8me pour la maintenance et les essais.<\/p>\n<p><strong>Aspiration de la pompe \u00e0 incendie.<\/strong> UV0199 OS&amp;Y \u00e0 bride c\u00f4t\u00e9 aspiration de chaque pompe \u00e0 incendie conform\u00e9ment \u00e0 la section 4.16 de la norme NFPA 20. La pression de service de 300 psi CWP couvre un service de colonne montante typique de 100 \u00e0 175 psi.<\/p>\n<p><strong>Refoulement de la pompe \u00e0 incendie.<\/strong> La vanne UV0199 OS&amp;Y est \u00e0 brides c\u00f4t\u00e9 refoulement. Lorsque la pression de refoulement des pompes incendie pour immeubles de grande hauteur d\u00e9passe 300 psi (500 psi pour les colonnes montantes de grande hauteur), veuillez contacter ValveAtlas pour obtenir une vanne \u00e0 guillotine \u00e0 brides de classe 500 psi.<\/p>\n<p><strong>Raccordements aux conduites d&#039;eau souterraines.<\/strong> Porte UV0299 NRS dans un regard de vannes en limite de propri\u00e9t\u00e9, au-dessus de laquelle un PIV (UV0800-IP) est install\u00e9 pour indication visuelle. La section 6.3 de la norme NFPA 24 traite des exigences relatives aux PIV.<\/p>\n<p><strong>Contr\u00f4le de zone de la colonne montante.<\/strong> UV0199 OS&amp;Y \u00e0 chaque entr\u00e9e de zone de colonne montante. La norme NFPA 14, chapitre 6, exige une vanne indicatrice homologu\u00e9e avec surveillance anti-effraction.<\/p>\n<h2 class=\"wp-block-heading\">Matrice de substitution de Victaulic, Nibco, Milwaukee, Mueller<\/h2>\n<p><strong>Porte OS&amp;Y s\u00e9rie 771 Victaulic.<\/strong> Remplacer par UNIVAL UV0199. Homologu\u00e9 UL\/ULC\/FM, pression de service de 300 psi, raccord \u00e0 brides. Voir la documentation. <a href=\"https:\/\/valve-atlas.com\/unival-vs-victaulic-fire-protection\/\">Comparaison entre UNIVAL et Victaulic<\/a>.<\/p>\n<p><strong>Porte OS&amp;Y Nibco F-607-OTS et F-607-RWS.<\/strong> Remplacez UV0199. Homologu\u00e9 UL\/ULC\/FM, 300 psi CWP, \u00e0 brides.<\/p>\n<p><strong>Porte OS&amp;Y Milwaukee MW-F-2882.<\/strong> Remplacez UV0199. Homologu\u00e9 UL\/FM.<\/p>\n<p><strong>Porte Mueller A-2361-20 NRS.<\/strong> Remplacer par UV0299 NRS. Homologu\u00e9 UL\/ULC\/FM, MJ ou \u00e0 bride.<\/p>\n<p><strong>Kennedy K-81A PIV.<\/strong> Remplacer par la vanne indicatrice de position UV0800-IP. Homologu\u00e9e UL\/ULC\/FM.<\/p>\n<h2 class=\"wp-block-heading\">Stock r\u00e9gional et livraison pour les vannes \u00e0 guillotine<\/h2>\n<p><strong>Toronto.<\/strong> Raccord \u00e0 brides OS&amp;Y UV0199 de 2 \u00e0 8 pouces en stock au si\u00e8ge social de Toronto pour exp\u00e9dition le jour m\u00eame. Raccords UV0299 et UV0800-IP en stock pour les projets de conduites d&#039;eau souterraines en Ontario.<\/p>\n<p><strong>Montr\u00e9al.<\/strong> Livraison de fret routier le lendemain depuis Toronto. Documentation RBQ avec certificat ULC. Documentation technique en fran\u00e7ais disponible.<\/p>\n<p><strong>New York.<\/strong> Livraison par camion en 2 jours depuis Toronto. Le service des incendies de la ville de New York (NYC DOB) et le service d&#039;incendie de New York (FDNY) acceptent le certificat UL. Vannes de refoulement des pompes incendie pour immeubles de grande hauteur pr\u00e9-install\u00e9es pour les chantiers des a\u00e9roports JFK, LGA et Manhattan.<\/p>\n<p><strong>Boston.<\/strong> Livraison par camion en 2 jours depuis Toronto. Acceptation des normes BFD et 780 CMR selon la certification UL.<\/p>\n<p><strong>Londres, Royaume-Uni.<\/strong> L&#039;entrep\u00f4t partenaire britannique dispose en stock de pi\u00e8ces de 4 et 6 pouces (UV0199 OS&amp;Y). Les pi\u00e8ces de 8 pouces et plus sont livr\u00e9es par fret a\u00e9rien en 5 \u00e0 7 jours via Heathrow.<\/p>\n<h2 class=\"wp-block-heading\">Produits connexes pour l&#039;entretien complet des colonnes montantes et des conduites d&#039;eau principales<\/h2>\n<p><strong>Vannes d&#039;alarme.<\/strong> UVW-1511-300 alarme humide, UVD-2511-300 conduite s\u00e8che, UVPR-5311-300 pr\u00e9action, UVPPD d\u00e9luge en aval de la vanne.<\/p>\n<p><strong>Vannes papillon.<\/strong> Papillon rainur\u00e9 UVB-G310 pour l&#039;isolation de zone en aval de la vanne. Voir <a href=\"https:\/\/valve-atlas.com\/butterfly-valves-fire-protection\/\">vannes papillon<\/a>.<\/p>\n<p><strong>Clapets anti-retour.<\/strong> Clapet anti-retour \u00e0 battant homologu\u00e9 sur le refoulement de la pompe \u00e0 incendie associ\u00e9 \u00e0 la vanne UV0199 et sur l&#039;ensemble anti-retour en amont.<\/p>\n<p><strong>Accouplements rainur\u00e9s.<\/strong> UV11 rigide et UV14 flexible sur les transitions bride-rainure. Voir <a href=\"https:\/\/valve-atlas.com\/coupling-fittings-products\/\">Raccords d&#039;accouplement<\/a>.<\/p>\n<p><strong>Interrupteurs anti-sabotage.<\/strong> Interrupteurs anti-sabotage homologu\u00e9s UL sur chaque vanne indicatrice (\u00e9quivalents Potter PIBV ou System Sensor) c\u00e2bl\u00e9s au panneau d&#039;alarme incendie conform\u00e9ment \u00e0 la section 17.16 de la norme NFPA 72.<\/p>\n<h2 class=\"wp-block-heading\">Foire aux questions<\/h2>\n<p><strong>Quelle est la diff\u00e9rence entre OS&amp;Y et NRS\u00a0?<\/strong> Le syst\u00e8me OS&amp;Y poss\u00e8de une tige montante (la tige filet\u00e9e sort de l&#039;\u00e9trier lors de l&#039;ouverture, offrant une indication visuelle). Le syst\u00e8me NRS poss\u00e8de une tige fixe (la tige reste interne\u00a0; l&#039;ouverture est signal\u00e9e par un indicateur de poteau s\u00e9par\u00e9 ou un dispositif de surveillance de chambre). Le syst\u00e8me OS&amp;Y est utilis\u00e9 en surface lorsqu&#039;il est visible\u00a0; le syst\u00e8me NRS est utilis\u00e9 en sous-sol ou dans des chambres de tirage.<\/p>\n<p><strong>Le mod\u00e8le UV0199 n\u00e9cessite-t-il un interrupteur d&#039;inviolabilit\u00e9\u00a0?<\/strong> Oui. Les normes NFPA 72, section 17.16 et BS EN 12845, section 20, exigent une surveillance anti-sabotage sur chaque vanne indicatrice commandant une zone d&#039;extinction automatique \u00e0 eau ou de colonne montante. Le mod\u00e8le UV0199 est livr\u00e9 avec un interrupteur anti-sabotage install\u00e9 en usine sur l&#039;\u00e9trier.<\/p>\n<p><strong>Quelle classe de pression couvre le refoulement des pompes \u00e0 incendie en immeubles de grande hauteur\u00a0?<\/strong> La norme UV0199 est con\u00e7ue pour une pression de refoulement de 300 psi. Pour les refoulements de colonnes montantes d&#039;immeubles de grande hauteur \u00e0 500 psi (refoulement de pompes pour immeubles de grande hauteur en zone 2 ou 3), ValveAtlas propose la variante de vanne OS&amp;Y de classe 500 psi. Veuillez indiquer la pression de refoulement de la pompe sur votre bon de commande\u00a0; ValveAtlas confirmera la disponibilit\u00e9 en stock ou le d\u00e9lai de livraison.<\/p>\n<p><strong>Le produit UV0299 NRS peut-il \u00eatre utilis\u00e9 en surface\u00a0?<\/strong> Techniquement, oui, mais la configuration NRS ne comporte pas de tige visible indiquant l&#039;ouverture\/fermeture. Son utilisation hors sol n\u00e9cessite un indicateur de position (PIA) pour une indication visuelle, ce qui annule l&#039;avantage \u00e9conomique de la configuration NRS. Utilisez le mod\u00e8le UV0199 OS&amp;Y hors sol\u00a0; le mod\u00e8le UV0299 NRS est r\u00e9serv\u00e9 aux installations enterr\u00e9es ou sous chambre.<\/p>\n<p><strong>Quelle est la diff\u00e9rence entre l&#039;ensemble indicateur UV0800-IP PIV et l&#039;ensemble indicateur de poteau\u00a0?<\/strong> Le mod\u00e8le UV0800-IP est un ensemble PIV complet\u00a0: vanne NRS, tige verticale enterr\u00e9e et indicateur de niveau hors sol, le tout formant un seul assemblage homologu\u00e9. Un ensemble indicateur de niveau hors sol (PIA) est constitu\u00e9 uniquement de l&#039;indicateur de niveau et s&#039;installe en remplacement d&#039;une vanne \u00e0 guillotine NRS existante. ValveAtlas fournit les ensembles PIV complets UV0800-IP pour les nouvelles constructions ainsi que les ensembles indicateurs de niveau hors sol (PIA) pour les installations existantes.<\/p>\n<h2 class=\"wp-block-heading\">Contactez ValveAtlas pour obtenir un devis de vanne \u00e0 guillotine<\/h2>\n<p>Pour obtenir un devis de vannes \u00e0 guillotine ou un dossier de soumission rempla\u00e7ant les sp\u00e9cifications Victaulic, Nibco, Milwaukee, Mueller ou Kennedy par celles d&#039;UNIVAL pour des projets \u00e0 Toronto, Montr\u00e9al, New York, Boston ou Londres, veuillez envoyer le cahier des charges et les plans par courriel \u00e0 burakpadr@gmail.com ou via le formulaire de contact. D\u00e9lai de r\u00e9ponse standard\u00a0: 48\u00a0heures.<\/p>\n<p>Pour consulter le tableau de correspondance UNIVAL complet, voir le <a href=\"https:\/\/valve-atlas.com\/unival-cross-reference\/\">R\u00e9f\u00e9rence crois\u00e9e UNIVAL<\/a>.<\/p>\n<div class=\"va-regions\">\n<h3>Vannes \u00e0 guillotine par r\u00e9gion<\/h3>\n<ul>\n<li><a href=\"\/gate-valves-toronto\/\">Toronto<\/a><\/li>\n<li><a href=\"\/gate-valves-new-york\/\">New York<\/a><\/li>\n<li><a href=\"\/gate-valves-boston\/\">Boston<\/a><\/li>\n<li><a href=\"\/gate-valves-london\/\">Londres, Royaume-Uni<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Gate Valves for Fire Protection: UL, ULC and FM Listed UNIVAL UV0199 and UV0299 Supply ValveAtlas supplies UL Listed, ULC Listed and FM Approved UNIVAL UV0199 OS&#038;Y (outside screw and yoke) gate valves and UV0299 NRS (non-rising stem) gate valves for sprinkler riser isolation, fire pump suction and discharge, underground water main tie-ins, post indicator&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"content-type":"","iawp_total_views":2,"footnotes":""},"class_list":["post-41659","page","type-page","status-publish","hentry","description-off"],"acf":[],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41659","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=41659"}],"version-history":[{"count":7,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41659\/revisions"}],"predecessor-version":[{"id":43738,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41659\/revisions\/43738"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=41659"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}