{"id":41653,"date":"2026-04-21T04:37:15","date_gmt":"2026-04-21T04:37:15","guid":{"rendered":"https:\/\/valve-atlas.com\/wet-alarm-valves\/"},"modified":"2026-05-11T04:41:45","modified_gmt":"2026-05-11T04:41:45","slug":"wet-alarm-valves","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/wet-alarm-valves\/","title":{"rendered":"Vannes d&#039;alarme humides"},"content":{"rendered":"<style>\ndiv.va-loc { font-family: Outfit, -apple-system, sans-serif !important; max-width: 1200px !important; margin: 32px auto !important; padding: 0 24px !important; box-sizing: border-box; }\ndiv.va-loc h2 { border-bottom: 3px solid #0B5ED7 !important; padding-bottom: 8px !important; margin-top: 48px !important; margin-bottom: 20px !important; color: #021228 !important; font-size: 32px !important; }\ndiv.va-loc h3 { color: #021228 !important; margin-top: 32px !important; margin-bottom: 12px !important; font-size: 22px !important; }\ndiv.va-loc p { color: rgba(2,18,40,0.82) !important; line-height: 1.7 !important; margin-bottom: 16px !important; font-size: 17px !important; }\ndiv.va-loc ul { padding-left: 24px !important; margin: 16px 0 24px !important; }\ndiv.va-loc ul li { color: rgba(2,18,40,0.82) !important; line-height: 1.8 !important; margin-bottom: 8px !important; list-style: disc !important; font-size: 17px !important; }\ndiv.va-loc strong { color: #021228 !important; }\ndiv.va-loc a { color: #0B5ED7 !important; text-decoration: underline !important; }\ndiv.va-loc a:hover { color: #021228 !important; }\ndiv.va-loc table { border-collapse: collapse; width: 100%; margin: 24px 0; background: white; border: 1px solid #E2E8F0; border-radius: 8px; overflow: hidden; }\ndiv.va-loc table th { background: #021228; color: white; padding: 12px 16px; text-align: left; font-weight: 600; }\ndiv.va-loc table td { padding: 12px 16px; border-top: 1px solid #E2E8F0; color: rgba(2,18,40,0.82); }\ndiv.va-loc table tr:nth-child(even) td { background: #F8FAFC; }\ndiv.va-loc .va-regions { background: #F8FAFC !important; border: 1px solid #E2E8F0 !important; border-radius: 12px !important; padding: 24px 28px !important; margin: 32px 0 !important; }\ndiv.va-loc .va-regions h3 { margin-top: 0 !important; color: #021228 !important; }\ndiv.va-loc .va-regions ul { list-style: none !important; padding: 0 !important; display: grid !important; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)) !important; gap: 8px !important; }\ndiv.va-loc .va-regions ul li { list-style: none !important; margin: 0 !important; }\ndiv.va-loc .va-regions a { display: block !important; padding: 10px 14px !important; border: 1px solid #E2E8F0 !important; border-radius: 8px !important; background: white !important; color: #0B5ED7 !important; text-decoration: none !important; text-align: center !important; font-weight: 500 !important; }\ndiv.va-loc .va-regions a:hover { background: #0B5ED7 !important; color: white !important; }\n<\/style>\n<div class=\"va-loc\" style=\"max-width:1200px;margin:32px auto;padding:0 24px;font-family:Outfit,-apple-system,sans-serif;box-sizing:border-box;\">\n<h2 class=\"wp-block-heading\">Vannes d&#039;alarme humides : homologu\u00e9es UL et FM, UNIVAL UVW-1511-300<\/h2>\n<p>ValveAtlas fournit des vannes d&#039;alarme \u00e0 pression d&#039;eau UNIVAL UVW-1511-300 homologu\u00e9es UL et FM pour les colonnes montantes de sprinklers et les colonnes s\u00e8ches, sur des projets \u00e0 Toronto, Montr\u00e9al, New York, Boston et Londres. L&#039;UVW-1511-300 est une vanne d&#039;alarme \u00e0 pression d&#039;eau de classe 300 psi avec chambre de temporisation int\u00e9gr\u00e9e, raccord pour avertisseur sonore hydraulique, prises pour manom\u00e8tre et collecteur de vidange\u00a0; c&#039;est la vanne de non-retour standard pour les alarmes de colonnes montantes de sprinklers dans les projets commerciaux, r\u00e9sidentiels, industriels et institutionnels.<\/p>\n<p>Cette page constitue la r\u00e9f\u00e9rence technique pour les ing\u00e9nieurs, les entreprises de construction, les entreprises de projets EPC et les sous-traitants en m\u00e9canique qui s\u00e9lectionnent les vannes d&#039;alarme \u00e0 eau sur les syst\u00e8mes de protection incendie r\u00e9gis par les normes NFPA 13, NFPA 72, BS EN 12845 Section 15, Document approuv\u00e9 B, Code du Qu\u00e9bec Chapitre B\u00e2timent et le Code m\u00e9canique de la ville de New York.<\/p>\n<h2 class=\"wp-block-heading\">Gamme de vannes d&#039;alarme humides UNIVAL chez ValveAtlas<\/h2>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>UGS UNIVERSELLE<\/th>\n<th>Taper<\/th>\n<th>classe de pression<\/th>\n<th>Garniture<\/th>\n<th>Annonces<\/th>\n<th>Tailles<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>UVW-1511-300<\/strong><\/td>\n<td>Vanne d&#039;alarme humide avec temporisation, raccords rainur\u00e9s et \u00e0 brides<\/td>\n<td>300 psi CWP<\/td>\n<td>\u00c9quipement d&#039;usine complet\u00a0: chambre de retard, manom\u00e8tres, purge, test, ligne d&#039;alarme<\/td>\n<td>UL et FM<\/td>\n<td>2\u00bd&quot; \u00e0 8&quot;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">Fonctionnement d&#039;une vanne d&#039;alarme \u00e0 eau<\/h2>\n<p>Le clapet anti-retour UVW-1511-300 est install\u00e9 \u00e0 la base de chaque colonne montante d&#039;extinction automatique \u00e0 eau. Lorsque le d\u00e9bit d&#039;eau du syst\u00e8me d\u00e9passe le seuil de pression diff\u00e9rentielle du clapet (l&#039;ouverture d&#039;une t\u00eate d&#039;extincteur correspond au d\u00e9clenchement minimal), le clapet se soul\u00e8ve et l&#039;eau s&#039;\u00e9coule par l&#039;orifice d&#039;alarme vers la chambre de temporisation. Cette chambre filtre les fluctuations de pression transitoires (coup de b\u00e9lier, d\u00e9marrages brusques de la pompe) afin d&#039;\u00e9viter les fausses alarmes et assure un d\u00e9bit constant vers le avertisseur sonore du moteur hydraulique et vers le pressostat \u00e9lectrique situ\u00e9 sur la ligne d&#039;alarme. Le pressostat est reli\u00e9 au panneau de commande du syst\u00e8me d&#039;alarme incendie pour d\u00e9clencher une alarme de d\u00e9bit d&#039;eau, conform\u00e9ment \u00e0 la norme NFPA 72, section 17.5.<\/p>\n<p>La garniture d&#039;usine sur UVW-1511-300 comprend : manom\u00e8tre c\u00f4t\u00e9 syst\u00e8me, manom\u00e8tre c\u00f4t\u00e9 alimentation, vanne \u00e0 bille de vidange principale, vidange principale de 2 pouces, connexion de test d&#039;inspecteur \u00e0 1 \u00e0 2 fois le plus petit orifice d&#039;arroseur, ligne d&#039;alarme avec connexion de pressostat, chambre de retard avec goutte automatique, connexion de gong de moteur d&#039;eau avec garniture et isolation de la vanne \u00e0 bille.<\/p>\n<h2 class=\"wp-block-heading\">Inscriptions et acceptation des codes<\/h2>\n<p><strong>UL 193.<\/strong> La vanne UNIVAL UVW-1511-300 est conforme \u00e0 la norme UL 193 (vannes d&#039;alarme pour la protection incendie). Le certificat UL est d\u00e9livr\u00e9 au fabricant UNIVAL et est inclus dans le dossier de soumission ValveAtlas.<\/p>\n<p><strong>Homologation UL pour les projets canadiens.<\/strong> L&#039;homologation UL couvre la m\u00eame UGS sous la norme CAN\/UL-S543. Les projets RBQ du Qu\u00e9bec et OBC Partie 3 de l&#039;Ontario acceptent le certificat UL.<\/p>\n<p><strong>Approbation FM.<\/strong> L&#039;homologation FM de classe 1041 (clapets anti-retour d&#039;alarme pour conduites humides) certifie le mod\u00e8le UVW-1511-300 pour les biens assur\u00e9s par FM conform\u00e9ment aux fiches techniques FM Global 2-0 et FM Global 3-0. Les experts en assurance de FM Global, RSA, Aviva, Zurich, Allianz, AXA Commercial, Chubb, AIG, Travelers et Intact acceptent le certificat FM pour leurs biens assur\u00e9s.<\/p>\n<p><strong>Acceptation LPCB et Royaume-Uni.<\/strong> Les projets britanniques relevant des normes BS EN 12845, sections 6 (alimentation en eau) et 15 (alarmes et pressostats), acceptent la certification UL\/FM lorsque le champ d&#039;application est reconnu par le LPCB conform\u00e9ment \u00e0 la norme LPS 1039. Pour les certificats sp\u00e9cifiques au LPCB requis pour les sp\u00e9cifications britanniques li\u00e9es \u00e0 l&#039;assurance, veuillez vous renseigner aupr\u00e8s de l&#039;expert en assurance.<\/p>\n<h2 class=\"wp-block-heading\">Emplacement de la vanne d&#039;alarme humide sur la colonne montante d&#039;un gicleur<\/h2>\n<p>Chaque syst\u00e8me d&#039;extinction automatique \u00e0 eau sous pression comporte une vanne d&#039;alarme de fuite \u00e0 la base de la colonne montante (NFPA 13, section 7.1.2). La configuration typique d&#039;une colonne montante, de bas en haut, est la suivante\u00a0:<\/p>\n<p>1. Robinet d&#039;eau souterrain ou robinet d&#039;eau de ville<br \/>2. Dispositif anti-refoulement (lorsque requis par la norme NFPA 13 et le code relatif aux interconnexions)<br \/>3. Vanne \u00e0 guillotine OS&amp;Y (UV0199) ou vanne \u00e0 guillotine NRS (UV0299) pour l&#039;isolement<br \/>4. Vanne de vidange principale situ\u00e9e au-dessus du robinet pour l&#039;isolement et la vidange du syst\u00e8me.<br \/>5. Manom\u00e8tre c\u00f4t\u00e9 alimentation<br \/>6. <strong>Vanne d&#039;alarme humide (UVW-1511-300)<\/strong><br \/>7. Manom\u00e8tre c\u00f4t\u00e9 syst\u00e8me<br \/>8. Raccordement de la ligne d&#039;alarme au avertisseur sonore du moteur \u00e0 eau et au pressostat \u00e9lectrique du panneau de commande de l&#039;alarme incendie<br \/>9. Raccord de test de l&#039;inspecteur au-dessus de la vanne d&#039;alarme pour les tests annuels NFPA 25<br \/>10. Alimentation principale des sprinklers vers les vannes papillon de zone (UVB-G310) et les conduites de d\u00e9rivation des sprinklers<\/p>\n<p>Pour les b\u00e2timents multizones, la vanne d&#039;alarme d&#039;humidit\u00e9 est install\u00e9e \u00e0 la base de chaque colonne montante verticale. Un ensemble de commande d&#039;\u00e9tage (ECE) est install\u00e9 \u00e0 chaque \u00e9tage et comprend un d\u00e9tecteur de d\u00e9bit, une vanne \u00e0 bille ou papillon anti-sabotage et un dispositif de contr\u00f4le. Le mod\u00e8le UVW-1511-300 correspond \u00e0 la vanne de base de colonne montante\u00a0; les d\u00e9tecteurs de d\u00e9bit au niveau de l&#039;\u00e9tage sont vendus s\u00e9par\u00e9ment (combinaison de d\u00e9tecteur de d\u00e9bit et de vanne d&#039;arr\u00eat homologu\u00e9e).<\/p>\n<h2 class=\"wp-block-heading\">Matrice de substitution de Victaulic, Tyco, Viking, Reliable<\/h2>\n<p>Les cahiers des charges mentionnent syst\u00e9matiquement les vannes d&#039;alarme \u00e0 bain d&#039;huile Victaulic, Tyco, Viking ou Reliable par leur r\u00e9f\u00e9rence. UNIVAL propose des \u00e9quivalents comme suit.<\/p>\n<p><strong>Valve d&#039;alarme Victaulic FireLock s\u00e9rie 751.<\/strong> Remplacez par UNIVAL UVW-1511-300. M\u00eame pression de service de 300 psi, m\u00eame port\u00e9e de la certification UL\/FM, m\u00eame configuration d&#039;usine. Voir la <a href=\"https:\/\/valve-atlas.com\/unival-vs-victaulic-fire-protection\/\">Comparaison entre UNIVAL et Victaulic<\/a>.<\/p>\n<p><strong>Vanne d&#039;alarme Tyco AV-1-300 et AV-2.<\/strong> Remplacer par UVW-1511-300. Homologu\u00e9 UL\/FM, pression de service de 300 psi, raccords rainur\u00e9s et \u00e0 brides disponibles. Voir <a href=\"https:\/\/valve-atlas.com\/unival-vs-tyco-fire-sprinklers\/\">Comparaison entre UNIVAL et Tyco<\/a>.<\/p>\n<p><strong>Vanne d&#039;alarme Viking mod\u00e8le J-1.<\/strong> Remplacez par UVW-1511-300. Homologu\u00e9 UL\/FM, garniture d&#039;usine compl\u00e8te. Voir <a href=\"https:\/\/valve-atlas.com\/unival-vs-viking-fire-protection\/\">Comparaison entre UNIVAL et Viking<\/a>.<\/p>\n<p><strong>Vanne d&#039;alarme mod\u00e8le F fiable.<\/strong> Remplacer par UVW-1511-300. Homologu\u00e9 UL\/FM. Voir <a href=\"https:\/\/valve-atlas.com\/unival-vs-reliable-fire-protection\/\">Comparaison entre UNIVAL et Reliable<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">Stock r\u00e9gional et livraison pour les vannes d&#039;alarme humides<\/h2>\n<p><strong>Toronto.<\/strong> UVW-1511-300 2\u00bd\u201d \u00e0 8\u201d en stock au si\u00e8ge social de Toronto avec garniture d&#039;usine compl\u00e8te pour une exp\u00e9dition le jour m\u00eame dans tout l&#039;Ontario et la r\u00e9gion du Grand Toronto.<\/p>\n<p><strong>Montr\u00e9al.<\/strong> Livraison par camion le lendemain depuis Toronto. Dossier de soumission en fran\u00e7ais avec certificat UL fourni pour les demandes de qualification de la r\u00e9glementation (RBQ).<\/p>\n<p><strong>New York.<\/strong> Livraison par camion en 2 jours depuis Toronto. Le service des urgences de New York (NYC DOB et FDNY) accepte le certificat UL pour UVW-1511-300. Livraison express par avion via JFK ou Newark\u00a0: \u00e0 organiser au cas par cas.<\/p>\n<p><strong>Boston.<\/strong> Livraison par camion en 2 jours depuis Toronto. Acceptation BFD selon la norme UL et la norme 780 CMR.<\/p>\n<p><strong>Londres, Royaume-Uni.<\/strong> L&#039;entrep\u00f4t partenaire britannique dispose en stock de mod\u00e8les UVW-1511-300 de 3 et 4 pouces avec garnitures compl\u00e8tes, livrables en 48 heures dans le centre de Londres. Le si\u00e8ge social de Toronto exp\u00e9die les mod\u00e8les de 6 et 8 pouces par fret a\u00e9rien (5 \u00e0 7 jours) via Heathrow.<\/p>\n<h2 class=\"wp-block-heading\">Produits associ\u00e9s pour un syst\u00e8me de tuyauterie humide complet<\/h2>\n<p><strong>Vannes \u00e0 guillotine.<\/strong> Porte \u00e0 bride UV0199 OS&amp;Y ou porte UV0299 NRS pour l&#039;isolation de la colonne montante en amont de la vanne d&#039;alarme humide.<\/p>\n<p><strong>Vannes papillon.<\/strong> Vanne papillon rainur\u00e9e UVB-G310 avec dispositif anti-effraction pour l&#039;isolation de zone en aval de la vanne d&#039;alarme humide. Voir <a href=\"https:\/\/valve-atlas.com\/butterfly-valves-fire-protection\/\">Vannes papillon pour la protection incendie<\/a> page pilier.<\/p>\n<p><strong>Accouplements rainur\u00e9s.<\/strong> Raccords rigides UV11 300 psi CWP et flexibles UV14 300 psi CWP sur les connexions de la colonne montante et au-dessus de la vanne d&#039;alarme. Voir <a href=\"https:\/\/valve-atlas.com\/coupling-fittings-products\/\">Raccords d&#039;accouplement<\/a>.<\/p>\n<p><strong>Arroseurs automatiques.<\/strong> Sur les branches d&#039;arrosage en aval\u00a0: arroseur suspendu UV320 SR, arroseur suspendu UV321 QR, arroseur mural lat\u00e9ral UV340 SR, arroseur mural lat\u00e9ral UV341 QR, arroseur dissimul\u00e9 UV820 SR et arroseur dissimul\u00e9 UV821 QR. Voir <a href=\"https:\/\/valve-atlas.com\/fire-sprinklers\/\">Gicleurs d&#039;incendie<\/a> moyeu.<\/p>\n<p><strong>Tester et vidanger.<\/strong> Station de test et de vidange bidirectionnelle homologu\u00e9e au niveau du raccord de test de l&#039;inspecteur, conform\u00e9ment \u00e0 la norme NFPA 13, section 16.9, pour l&#039;essai annuel de d\u00e9bit d&#039;eau. Voir <a href=\"https:\/\/valve-atlas.com\/test-and-drain-valves\/\">Vannes de test et de purge<\/a>.<\/p>\n<h2 class=\"wp-block-heading\">Foire aux questions<\/h2>\n<p><strong>\u00c0 quoi sert la chambre de retard ?<\/strong> La chambre de temporisation est un petit r\u00e9servoir situ\u00e9 sur la conduite d&#039;alarme qui se remplit d&#039;eau lors du d\u00e9clenchement du clapet. Elle retarde le signal d&#039;alarme de 30 \u00e0 60 secondes, permettant ainsi aux fluctuations de pression transitoires (coup de b\u00e9lier, d\u00e9marrage de la pompe de maintien de pression) de se dissiper sans provoquer de fausse alarme. Un d\u00e9bit soutenu vide la chambre de temporisation au-del\u00e0 de son clapet de sortie et active le gong du moteur hydraulique et le pressostat, d\u00e9clenchant ainsi une v\u00e9ritable alarme de d\u00e9bit.<\/p>\n<p><strong>Le mod\u00e8le UVW-1511-300 inclut-il le gong du moteur \u00e0 eau\u00a0?<\/strong> Le kit de garniture pour vanne d&#039;alarme \u00e0 eau comprend le raccord et la vanne d&#039;isolement pour le gong \u00e0 moteur hydraulique, mais le gong lui-m\u00eame est un produit distinct. Veuillez pr\u00e9ciser la taille du gong (bo\u00eetier de 6 ou 8 pouces) sur le bon de commande\u00a0; ValveAtlas propose des gongs \u00e0 moteur hydraulique homologu\u00e9s UL\/FM en option.<\/p>\n<p><strong>Quels fils du pressostat sont raccord\u00e9s au panneau d&#039;alarme incendie\u00a0?<\/strong> Le pressostat de la ligne d&#039;alarme est un produit vendu s\u00e9par\u00e9ment (g\u00e9n\u00e9ralement le Potter PS10-2 ou \u00e9quivalent). La garniture UVW-1511-300 comprend le raccord NPT 1\/2\u2033 pour le pressostat\u00a0; ValveAtlas fournit le pressostat en tant que pi\u00e8ce compl\u00e9mentaire.<\/p>\n<p><strong>Quelle est la diff\u00e9rence entre une vanne d&#039;alarme humide et une vanne d&#039;alarme s\u00e8che\u00a0?<\/strong> La vanne d&#039;alarme \u00e0 eau (UVW-1511-300) prot\u00e8ge les syst\u00e8mes o\u00f9 la tuyauterie d&#039;extinction automatique est constamment sous pression d&#039;eau. La vanne d&#039;alarme \u00e0 air comprim\u00e9 (UVD-2511-300) prot\u00e8ge les syst\u00e8mes o\u00f9 la tuyauterie est sous pression d&#039;air et o\u00f9 l&#039;eau ne circule qu&#039;apr\u00e8s le d\u00e9clenchement d&#039;un sprinkler. Les syst\u00e8mes \u00e0 eau prot\u00e8gent les b\u00e2timents chauff\u00e9s\u00a0; les syst\u00e8mes \u00e0 air comprim\u00e9 prot\u00e8gent les entrep\u00f4ts non chauff\u00e9s, les parkings, les quais de chargement et les combles.<\/p>\n<p><strong>Le mod\u00e8le UVW-1511-300 peut-il \u00eatre install\u00e9 horizontalement\u00a0?<\/strong> Oui. Le mod\u00e8le UVW-1511-300 s&#039;installe verticalement ou horizontalement conform\u00e9ment \u00e0 la norme NFPA 13, section 7.1.3, et au manuel d&#039;installation du fabricant. L&#039;installation horizontale n\u00e9cessite un ajustement du cheminement de la ligne d&#039;alarme afin de maintenir la fonction de goutte \u00e0 goutte automatique sur la chambre de retardement.<\/p>\n<h2 class=\"wp-block-heading\">Contactez ValveAtlas pour un devis de vanne d&#039;alarme \u00e0 eau<\/h2>\n<p>Pour obtenir un devis concernant des vannes d&#039;alarme sous pression, ou pour soumettre un dossier technique rempla\u00e7ant les sp\u00e9cifications Victaulic, Tyco, Viking ou Reliable par celles d&#039;UNIVAL pour des projets \u00e0 Toronto, Montr\u00e9al, New York, Boston ou Londres, veuillez envoyer le cahier des charges et les plans par courriel \u00e0 burakpadr@gmail.com ou via le formulaire de contact de notre site web. Le d\u00e9lai de traitement standard est de 48 heures \u00e0 compter de la r\u00e9ception du cahier des charges.<\/p>\n<p>Pour consulter le tableau de correspondance UNIVAL complet, voir le <a href=\"https:\/\/valve-atlas.com\/unival-cross-reference\/\">R\u00e9f\u00e9rence crois\u00e9e UNIVAL<\/a>.<\/p>\n<div class=\"va-regions\">\n<h3>Vannes d&#039;alarme humides par r\u00e9gion<\/h3>\n<ul>\n<li><a href=\"\/wet-alarm-valves-toronto\/\">Toronto<\/a><\/li>\n<li><a href=\"\/wet-alarm-valves-montreal\/\">Montr\u00e9al<\/a><\/li>\n<li><a href=\"\/wet-alarm-valves-new-york\/\">New York<\/a><\/li>\n<li><a href=\"\/wet-alarm-valves-boston\/\">Boston<\/a><\/li>\n<li><a href=\"\/wet-alarm-valves-london\/\">Londres, Royaume-Uni<\/a><\/li>\n<\/ul>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Wet Alarm Valves: UL and FM Listed UNIVAL UVW-1511-300 Supply ValveAtlas supplies UL Listed, UL Listed and FM Approved UNIVAL UVW-1511-300 wet alarm valves for sprinkler riser and standpipe riser service on projects in Toronto, Montreal, New York, Boston and London. The UVW-1511-300 is the 300 psi class wet alarm valve with integrated retard chamber,&hellip;<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"content-type":"","iawp_total_views":0,"footnotes":""},"class_list":["post-41653","page","type-page","status-publish","hentry","description-off"],"acf":[],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=41653"}],"version-history":[{"count":8,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41653\/revisions"}],"predecessor-version":[{"id":43744,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41653\/revisions\/43744"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=41653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}