{"id":41640,"date":"2026-04-21T03:35:42","date_gmt":"2026-04-21T03:35:42","guid":{"rendered":"https:\/\/valve-atlas.com\/unival-cross-reference\/"},"modified":"2026-04-26T00:56:51","modified_gmt":"2026-04-26T00:56:51","slug":"unival-cross-reference","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/unival-cross-reference\/","title":{"rendered":"Tableau de correspondance UNIVAL\u00a0: \u00c9quivalents Tyco, Viking, Reliable et Victaulic"},"content":{"rendered":"<style>\ndiv.va-loc { font-family: Outfit, -apple-system, sans-serif !important; max-width: 1200px !important; margin: 32px auto !important; padding: 0 24px !important; box-sizing: border-box; }\ndiv.va-loc h2 { border-bottom: 3px solid #0B5ED7 !important; padding-bottom: 8px !important; margin-top: 48px !important; margin-bottom: 20px !important; color: #021228 !important; font-size: 32px !important; }\ndiv.va-loc h3 { color: #021228 !important; margin-top: 32px !important; margin-bottom: 12px !important; font-size: 22px !important; }\ndiv.va-loc p { color: rgba(2,18,40,0.82) !important; line-height: 1.7 !important; margin-bottom: 16px !important; font-size: 17px !important; }\ndiv.va-loc ul { padding-left: 24px !important; margin: 16px 0 24px !important; }\ndiv.va-loc ul li { color: rgba(2,18,40,0.82) !important; line-height: 1.8 !important; margin-bottom: 8px !important; list-style: disc !important; font-size: 17px !important; }\ndiv.va-loc strong { color: #021228 !important; }\ndiv.va-loc a { color: #0B5ED7 !important; text-decoration: underline !important; }\ndiv.va-loc a:hover { color: #021228 !important; }\ndiv.va-loc table { border-collapse: collapse; width: 100%; margin: 24px 0; background: white; border: 1px solid #E2E8F0; border-radius: 8px; overflow: hidden; }\ndiv.va-loc table th { background: #021228; color: white; padding: 12px 16px; text-align: left; font-weight: 600; }\ndiv.va-loc table td { padding: 12px 16px; border-top: 1px solid #E2E8F0; color: rgba(2,18,40,0.82); }\ndiv.va-loc table tr:nth-child(even) td { background: #F8FAFC; }\ndiv.va-loc .va-regions { background: #F8FAFC !important; border: 1px solid #E2E8F0 !important; border-radius: 12px !important; padding: 24px 28px !important; margin: 32px 0 !important; }\ndiv.va-loc .va-regions h3 { margin-top: 0 !important; color: #021228 !important; }\ndiv.va-loc .va-regions ul { list-style: none !important; padding: 0 !important; display: grid !important; grid-template-columns: repeat(auto-fit, minmax(180px, 1fr)) !important; gap: 8px !important; }\ndiv.va-loc .va-regions ul li { list-style: none !important; margin: 0 !important; }\ndiv.va-loc .va-regions a { display: block !important; padding: 10px 14px !important; border: 1px solid #E2E8F0 !important; border-radius: 8px !important; background: white !important; color: #0B5ED7 !important; text-decoration: none !important; text-align: center !important; font-weight: 500 !important; }\ndiv.va-loc .va-regions a:hover { background: #0B5ED7 !important; color: white !important; }\n<\/style>\n<div class=\"va-loc\" style=\"max-width:1200px;margin:32px auto;padding:0 24px;font-family:Outfit,-apple-system,sans-serif;box-sizing:border-box;\">\n<h2 class=\"wp-block-heading\">Table de correspondance UNIVAL\u00a0: \u00c9quivalents Tyco, Viking, Reliable et Victaulic<\/h2>\n<p>Les prescripteurs r\u00e9digent les dossiers de protection incendie en fonction des r\u00e9f\u00e9rences des mod\u00e8les qu&#039;ils connaissent. Lorsqu&#039;un projet sp\u00e9cifie une vanne de conduite s\u00e8che Tyco DPV-1, un mod\u00e8le Viking E, un r\u00e9gulateur de pr\u00e9action Reliable DDX ou un raccord Victaulic Style 07, l&#039;ing\u00e9nieur prescripteur a en t\u00eate un profil de conformit\u00e9 et une norme dimensionnelle pr\u00e9cis. Cette page \u00e9tablit une correspondance entre les r\u00e9f\u00e9rences du catalogue UNIVAL et celles de ces mod\u00e8les concurrents bien connus, afin que les demandes de substitution \u201c\u00a0ou \u00e9quivalent\u00a0\u201d puissent \u00eatre rapidement compar\u00e9es \u00e0 un \u00e9quivalent pr\u00e9cis, tant en termes de r\u00e9f\u00e9rences que de dimensions.<\/p>\n<p>Les tableaux ci-dessous sont \u00e9tablis \u00e0 partir du catalogue de protection incendie UNIVAL et des fiches techniques publi\u00e9es par Tyco (Johnson Controls), Viking, Reliable Automatic Sprinkler et Victaulic. Ils comparent les dimensions, la classe de pression, le type de raccordement, le profil d&#039;homologation (UL\/ULC\/FM) et l&#039;usage pr\u00e9vu. L&#039;\u00e9quivalence ne signifie pas un remplacement direct dans tous les cas\u00a0; l&#039;ing\u00e9nieur concepteur doit approuver le remplacement et l&#039;installateur doit v\u00e9rifier la compatibilit\u00e9 des calculs hydrauliques, des ensembles de finition et du c\u00e2blage de supervision. Consultez la section \u201c\u00a0Comment utiliser ce tableau\u00a0\u201d en bas de page.<\/p>\n<h2 class=\"wp-block-heading\">Raccords et accessoires rainur\u00e9s (r\u00e9f\u00e9rence crois\u00e9e Victaulic)<\/h2>\n<p>Les raccords rainur\u00e9s UNIVAL sont homologu\u00e9s UL, ULC et FM selon les dimensions de rainurage AWWA C606, la m\u00eame norme que celle publi\u00e9e par Victaulic. Leurs extr\u00e9mit\u00e9s sont interchangeables avec celles des tuyaux rainur\u00e9s standard. Les joints sont en EPDM de grade E pour les applications d&#039;eau de protection incendie.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le Victaulic<\/th>\n<th>\u00c9quivalent UNIVAL<\/th>\n<th>Fonction<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Accouplement rigide Style 07 \u201c\u00a0Z\u00e9ro Flex\u00a0\u201d<\/td>\n<td><strong>UV11<\/strong><\/td>\n<td>Accouplement rigide, pression de service de 300 psi<\/td>\n<td>Rainurage AWWA C606. Boulons zingu\u00e9s de s\u00e9rie.<\/td>\n<\/tr>\n<tr>\n<td>Accouplement flexible de style 77<\/td>\n<td><strong>UV14<\/strong><\/td>\n<td>Accouplement flexible, pression de service de 300 psi<\/td>\n<td>D\u00e9flexion conforme aux normes industrielles. Id\u00e9al pour les joints soumis \u00e0 des vibrations et \u00e0 des mouvements thermiques.<\/td>\n<\/tr>\n<tr>\n<td>Style 005 \u201c FireLock \u201d rigide<\/td>\n<td><strong>UV15<\/strong><\/td>\n<td>Accouplement rigide renforc\u00e9, classe jusqu&#039;\u00e0 750 psi<\/td>\n<td>Pour le refoulement des colonnes montantes haute pression et des pompes incendie. Homologu\u00e9 UL\/FM pour les syst\u00e8mes de 300 et 500 psi.<\/td>\n<\/tr>\n<tr>\n<td>Style 177 flexible<\/td>\n<td><strong>UV16<\/strong><\/td>\n<td>Accouplement flexible robuste<\/td>\n<td>Variante flexible haute pression.<\/td>\n<\/tr>\n<tr>\n<td>Transition du style 47 au style 995<\/td>\n<td><strong>UV19<\/strong><\/td>\n<td>Accouplement rainur\u00e9 de transition<\/td>\n<td>Raccords adaptateurs acier-cuivre, acier-PVC.<\/td>\n<\/tr>\n<tr>\n<td>Raccord r\u00e9ducteur Style 750<\/td>\n<td><strong>UV09<\/strong><\/td>\n<td>R\u00e9duction du couplage<\/td>\n<td>R\u00e9ductions dimensionnelles dans les tuyauteries rainur\u00e9es.<\/td>\n<\/tr>\n<tr>\n<td>Adaptateur de bride de style 741<\/td>\n<td><strong>UV78<\/strong><\/td>\n<td>Adaptateur \u00e0 bride rainur\u00e9e<\/td>\n<td>Raccorde l&#039;extr\u00e9mit\u00e9 rainur\u00e9e directement aux composants \u00e0 brides ANSI B16.1 Classe 125 \/ 150.<\/td>\n<\/tr>\n<tr>\n<td>T\u00e9 m\u00e9canique Style 72 (sortie)<\/td>\n<td><strong>UV305<\/strong><\/td>\n<td>T\u00e9 m\u00e9canique rainur\u00e9, style sortie<\/td>\n<td>Sortie de ligne secondaire sans d\u00e9coupe ni soudure.<\/td>\n<\/tr>\n<tr>\n<td>Croix m\u00e9canique Style 920 (sortie)<\/td>\n<td><strong>UV307<\/strong><\/td>\n<td>Croix m\u00e9canique rainur\u00e9e, style sortie<\/td>\n<td>Prise \u00e0 quatre voies.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Gamme de tailles\u00a0: DN25 \u00e0 DN400 (1\u2033 \u00e0 16\u2033) pour les familles de raccords principaux. Les certifications UL, ULC et FM sont d\u00e9livr\u00e9es en fonction de la norme dimensionnelle et de la classe de pression indiqu\u00e9e, et non du nom du fabricant. La substitution est donc simple lorsque l\u2019autorit\u00e9 comp\u00e9tente accepte la gamme UNIVAL \u00e0 triple certification.<\/p>\n<h2 class=\"wp-block-heading\">Gicleurs d&#039;incendie (Tyco, Viking, Reliable - R\u00e9f\u00e9rence crois\u00e9e)<\/h2>\n<p>La gamme de sprinklers UNIVAL UV-3 propose des configurations K=5,6 (montantes, suspendues, murales et suspendues encastr\u00e9es) en versions \u00e0 r\u00e9ponse standard et \u00e0 r\u00e9ponse rapide. Les mod\u00e8les UV-3 K=5,6 sont homologu\u00e9s UL et FM\u00a0; les mod\u00e8les suspendus encastr\u00e9s (UV820\/UV821) et les sprinklers K=8,0 sont uniquement homologu\u00e9s UL.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le concurrent<\/th>\n<th>\u00c9quivalent UNIVAL<\/th>\n<th>Orientation et r\u00e9ponse<\/th>\n<th>Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tyco TY-B K=5,6 vertical, SR (TY3231)<\/td>\n<td><strong>UV310<\/strong><\/td>\n<td>Montant, r\u00e9ponse standard, K=5,6, laiton<\/td>\n<td>1\/2\u2033 NPT. Profil \u00e9quivalent \u00e0 la certification UL.<\/td>\n<\/tr>\n<tr>\n<td>Tyco TY-FRB K=5,6 vertical, QR (TY3121)<\/td>\n<td><strong>UV311<\/strong><\/td>\n<td>Vertical, r\u00e9ponse rapide, K=5,6, laiton<\/td>\n<td>1\/2\u2033 NPT. Utilisation typique en milieu \u00e0 faible risque d&#039;incendie.<\/td>\n<\/tr>\n<tr>\n<td>Pendentif Tyco TY-B K=5,6, SR<\/td>\n<td><strong>UV320<\/strong><\/td>\n<td>Pendentif, r\u00e9ponse standard, K=5,6, blanc\/chrome<\/td>\n<td>1\/2\u2033 NPT. Montage au plafond avec rosace.<\/td>\n<\/tr>\n<tr>\n<td>Pendentif Tyco TY-FRB K=5.6, QR<\/td>\n<td><strong>UV321<\/strong><\/td>\n<td>Pendentif, r\u00e9ponse rapide, K=5,6, blanc\/chrome<\/td>\n<td>1\/2\u2033 NPT. QR par d\u00e9faut pour les zones \u00e0 risque l\u00e9ger.<\/td>\n<\/tr>\n<tr>\n<td>Tyco Royal Flush RFII (TY3531) dissimul\u00e9<\/td>\n<td><strong>UV820<\/strong> (SR) ou <strong>UV821<\/strong> (QR)<\/td>\n<td>Pendentif dissimul\u00e9, K=5,6<\/td>\n<td>Plaque de recouvrement blanche standard. Homologu\u00e9e UL uniquement.<\/td>\n<\/tr>\n<tr>\n<td>\u00c9chappement vertical Viking s\u00e9rie VK300, SR<\/td>\n<td><strong>UV310<\/strong><\/td>\n<td>Montant droit, K=5,6, SR, laiton<\/td>\n<td>Liste \u00e9quivalente. V\u00e9rifiez la temp\u00e9rature de fonctionnement de l&#039;ampoule.<\/td>\n<\/tr>\n<tr>\n<td>Viking Microfast QR K=5,6 vertical<\/td>\n<td><strong>UV311<\/strong><\/td>\n<td>Montant, QR, K=5,6, laiton<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Pendentif QR Viking Microfast VK302<\/td>\n<td><strong>UV321<\/strong><\/td>\n<td>Pendentif, QR, K=5,6, blanc\/chrome<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Viking Mirage Concealed VK462<\/td>\n<td><strong>UV820<\/strong> (SR) ou <strong>UV821<\/strong> (QR)<\/td>\n<td>Pendentif dissimul\u00e9, K=5,6<\/td>\n<td>Correspondance de la couleur de la plaque de recouvrement\u00a0: le blanc est la finition standard en stock.<\/td>\n<\/tr>\n<tr>\n<td>Mod\u00e8le fiable F1FR56 K=5,6 QR vertical<\/td>\n<td><strong>UV311<\/strong><\/td>\n<td>Montant, QR, K=5,6, laiton<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Pendentif QR mod\u00e8le fiable F1FR56 K=5,6<\/td>\n<td><strong>UV321<\/strong><\/td>\n<td>Pendentif, QR, K=5,6, blanc\/chrome<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td>Pendentif dissimul\u00e9 Reliable Mod\u00e8le G4A \/ G5A<\/td>\n<td><strong>UV820<\/strong> (SR) ou <strong>UV821<\/strong> (QR)<\/td>\n<td>Pendentif dissimul\u00e9, K=5,6<\/td>\n<td>Couleurs personnalis\u00e9es des plaques de recouvrement disponibles sur demande pour UV820 \/ UV821.<\/td>\n<\/tr>\n<tr>\n<td>Flanc horizontal fiable mod\u00e8le F1<\/td>\n<td><strong>UV340<\/strong> (SR) ou <strong>UV341<\/strong> (QR)<\/td>\n<td>Paroi lat\u00e9rale horizontale, K=5,6<\/td>\n<td>Support mural avec rosace lat\u00e9rale.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Les sprinklers de la s\u00e9rie UNIVAL UV ne couvrent pas les applications ESFR (Early Suppression Fast Response) K=14,0 ou K=16,8, ni la couverture \u00e9tendue compl\u00e8te propos\u00e9e par Tyco et Viking pour leurs gammes de sprinklers \u00e0 coefficient K \u00e9lev\u00e9. Les projets n\u00e9cessitant une protection ESFR pour les rayonnages de stockage ou pour de tr\u00e8s grandes surfaces \u00e0 couvrir doivent respecter les sp\u00e9cifications d&#039;origine. Voir le <a href=\"https:\/\/valve-atlas.com\/unival-vs-tyco-fire-sprinklers\/\">Comparaison entre UNIVAL et Tyco<\/a>, <a href=\"https:\/\/valve-atlas.com\/unival-vs-viking-fire-protection\/\">Comparaison entre UNIVAL et Viking<\/a> et <a href=\"https:\/\/valve-atlas.com\/unival-vs-reliable-fire-protection\/\">Comparaison entre UNIVAL et Reliable<\/a> pour une discussion produit par produit, y compris lorsque le produit concurrent reste la bonne solution.<\/p>\n<h2 class=\"wp-block-heading\">Vannes d&#039;alarme (\u00e0 eau, \u00e0 sec, \u00e0 pr\u00e9action, \u00e0 d\u00e9luge)<\/h2>\n<p>Les vannes d&#039;alarme UNIVAL de classe 300 psi (UVW-1511-300, UVD-2511-300, UVPR-5311-300 et UVPPD) sont certifi\u00e9es UL et FM. Les kits de garniture sont vendus s\u00e9par\u00e9ment et comprennent des manom\u00e8tres, une chambre de temporisation, un avertisseur sonore pour moteur hydraulique, ainsi que des ensembles de purge et d&#039;amor\u00e7age conformes \u00e0 la norme NFPA 13.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le concurrent<\/th>\n<th>\u00c9quivalent UNIVAL<\/th>\n<th>Service<\/th>\n<th>Gamme de tailles<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Valve d&#039;alarme humide Tyco AV-1<\/td>\n<td><strong>UVW-1511-300<\/strong><\/td>\n<td>Clapet anti-retour pour colonne montante de tuyauterie humide avec alarme<\/td>\n<td>DN80 \/ DN100 \/ DN150 \/ DN200 (3\u2033 \/ 4\u2033 \/ 6\u2033 \/ 8\u2033)<\/td>\n<\/tr>\n<tr>\n<td>Valve d&#039;alarme humide Viking J-1<\/td>\n<td><strong>UVW-1511-300<\/strong><\/td>\n<td>Colonne montante de tuyau humide<\/td>\n<td>DN80 \u2013 DN200<\/td>\n<\/tr>\n<tr>\n<td>V\u00e9rification fiable de l&#039;alarme du mod\u00e8le F607<\/td>\n<td><strong>UVW-1511-300<\/strong><\/td>\n<td>Colonne montante de tuyau humide<\/td>\n<td>DN80 \u2013 DN200<\/td>\n<\/tr>\n<tr>\n<td>Vanne \u00e0 conduite s\u00e8che Tyco DPV-1<\/td>\n<td><strong>UVD-2511-300<\/strong><\/td>\n<td>colonne montante du syst\u00e8me de tuyauterie s\u00e8che, espace non chauff\u00e9 ou de cong\u00e9lation<\/td>\n<td>DN100 \/ DN150 (4\u2033 \/ 6\u2033)<\/td>\n<\/tr>\n<tr>\n<td>Vanne \u00e0 conduite s\u00e8che Viking mod\u00e8le E<\/td>\n<td><strong>UVD-2511-300<\/strong><\/td>\n<td>colonne montante du syst\u00e8me de tuyauterie s\u00e8che<\/td>\n<td>DN100 \/ DN150<\/td>\n<\/tr>\n<tr>\n<td>Vanne \u00e0 conduite s\u00e8che mod\u00e8le C fiable<\/td>\n<td><strong>UVD-2511-300<\/strong><\/td>\n<td>colonne montante du syst\u00e8me de tuyauterie s\u00e8che<\/td>\n<td>DN100 \/ DN150<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00e9action Tyco PV-1 ou AFV-1<\/td>\n<td><strong>UVPR-5311-300<\/strong><\/td>\n<td>pr\u00e9action \u00e0 verrouillage simple ou sans verrouillage<\/td>\n<td>DN100 \/ DN150<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00e9action Viking VFR \/ VFG<\/td>\n<td><strong>UVPR-5311-300<\/strong><\/td>\n<td>Configurations \u00e0 verrouillage simple ou double (selon la garniture)<\/td>\n<td>DN100 \/ DN150<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00e9action DDX fiable<\/td>\n<td><strong>UVPR-5311-300<\/strong><\/td>\n<td>Pr\u00e9action avec d\u00e9clenchement de type d\u00e9luge<\/td>\n<td>DN100 \/ DN150<\/td>\n<\/tr>\n<tr>\n<td>Vanne de d\u00e9luge Tyco DV-5A<\/td>\n<td><strong>UVPPD<\/strong><\/td>\n<td>D\u00e9luge, syst\u00e8mes \u00e0 t\u00eate ouverte<\/td>\n<td>DN100 \/ DN150 \/ DN200<\/td>\n<\/tr>\n<tr>\n<td>Viking Mod\u00e8le E-3 d\u00e9luge<\/td>\n<td><strong>UVPPD<\/strong><\/td>\n<td>D\u00e9luge, syst\u00e8mes \u00e0 t\u00eate ouverte<\/td>\n<td>DN100 \/ DN150 \/ DN200<\/td>\n<\/tr>\n<tr>\n<td>D\u00e9luge fiable mod\u00e8le DDX-LP<\/td>\n<td><strong>UVPPD<\/strong><\/td>\n<td>D\u00e9luge, syst\u00e8mes \u00e0 t\u00eate ouverte<\/td>\n<td>DN100 \/ DN150 \/ DN200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Les syst\u00e8mes \u00e0 pr\u00e9action avec double verrouillage n\u00e9cessitent une configuration sp\u00e9cifique des garnitures et du c\u00e2blage de supervision. Le panneau de d\u00e9clenchement (Notifier, EST, Potter, Silent Knight) commande g\u00e9n\u00e9ralement l&#039;\u00e9lectrovanne via un circuit de d\u00e9clenchement homologu\u00e9. Avant tout remplacement, v\u00e9rifiez la compatibilit\u00e9 de l&#039;\u00e9lectrovanne avec le panneau de d\u00e9clenchement, quel que soit le fabricant de l&#039;\u00e9lectrovanne d&#039;alarme install\u00e9e sur la colonne montante.<\/p>\n<h2 class=\"wp-block-heading\">Vannes \u00e0 guillotine, vannes papillon et clapets anti-retour<\/h2>\n<p>Les vannes \u00e0 guillotine UNIVAL OS&amp;Y (UV0199) et les vannes \u00e0 guillotine NRS (UV0299) sont homologu\u00e9es UL, ULC et FM avec un corps en fonte ductile et un rev\u00eatement \u00e9poxy, et des extr\u00e9mit\u00e9s \u00e0 brides ANSI B16.1 Classe 125 ou 250.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le concurrent<\/th>\n<th>\u00c9quivalent UNIVAL<\/th>\n<th>Fonction<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Victaulic FireLock n\u00b0 705 OS&amp;Y<\/td>\n<td><strong>UV0199<\/strong><\/td>\n<td>Vanne \u00e0 guillotine OS&amp;Y, \u00e0 brides, \u00e0 tige montante avec indication visible<\/td>\n<\/tr>\n<tr>\n<td>Valve Kennedy 4068 \/ 4071 OS&amp;Y<\/td>\n<td><strong>UV0199<\/strong><\/td>\n<td>Vanne \u00e0 guillotine OS&amp;Y, \u00e0 brides<\/td>\n<\/tr>\n<tr>\n<td>Porte Mueller A-2360 NRS<\/td>\n<td><strong>UV0299<\/strong><\/td>\n<td>Vanne \u00e0 guillotine NRS pour service souterrain \/ enterr\u00e9<\/td>\n<\/tr>\n<tr>\n<td>Porte Clow F-6100 NRS<\/td>\n<td><strong>UV0299<\/strong><\/td>\n<td>Vanne \u00e0 guillotine NRS pour sous-sol<\/td>\n<\/tr>\n<tr>\n<td>Valve indicatrice de position Mueller A-20806<\/td>\n<td><strong>UV0800-IP<\/strong><\/td>\n<td>Indicateur de position (PIV) pour indication murale ou ext\u00e9rieure<\/td>\n<\/tr>\n<tr>\n<td>Papillon rainur\u00e9 Tyco BFV-300<\/td>\n<td><strong>UVB-G310<\/strong><\/td>\n<td>Vanne papillon rainur\u00e9e avec interrupteur anti-sabotage, pression de service de 300 psi<\/td>\n<\/tr>\n<tr>\n<td>Papillon Victaulic S\u00e9rie 705 \/ 707C<\/td>\n<td><strong>UVB-G310<\/strong> ou <strong>UVB-W310<\/strong><\/td>\n<td>Papillon rainur\u00e9 ou \u00e0 plaquettes avec interrupteur anti-sabotage<\/td>\n<\/tr>\n<tr>\n<td>Valve papillon Milwaukee MW-300<\/td>\n<td><strong>UVB-W310<\/strong> ou <strong>UVB-L310<\/strong><\/td>\n<td>Plaquette ou papillon \u00e0 cosse<\/td>\n<\/tr>\n<tr>\n<td>Victaulic S\u00e9rie 716 \u00e0 carreaux rainur\u00e9s<\/td>\n<td><strong>UVSC-G310<\/strong><\/td>\n<td>v\u00e9rification de swing rainur\u00e9e<\/td>\n<\/tr>\n<tr>\n<td>V\u00e9rification de l&#039;oscillation Tyco SCV-1<\/td>\n<td><strong>UVSC-F310<\/strong><\/td>\n<td>V\u00e9rin \u00e0 bride<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">Contr\u00f4le de pression, vannes de tuyau, FDC et accessoires<\/h2>\n<p>Les vannes de r\u00e9gulation de pression UNIVAL (UPRV-0301, UPRV-1320, UPRV-1321) sont r\u00e9glables sur le terrain et couvrent la plage que les prescripteurs demandent g\u00e9n\u00e9ralement sur les syst\u00e8mes de colonnes montantes pour maintenir les pressions r\u00e9siduelles de sortie des tuyaux dans la fen\u00eatre admissible de la norme NFPA 14.<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le concurrent<\/th>\n<th>\u00c9quivalent UNIVAL<\/th>\n<th>Fonction<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>R\u00e9gulateur de pression Zurn Wilkins 600XL ou Watts 750<\/td>\n<td><strong>UPRV-0301<\/strong><\/td>\n<td>Soupape de s\u00fbret\u00e9 r\u00e9glable en ligne, \u00e0 brides<\/td>\n<\/tr>\n<tr>\n<td>Soupape de s\u00fbret\u00e9 \u00e0 angle Croker 3005, 2,5\u2033<\/td>\n<td><strong>UPRV-1320<\/strong><\/td>\n<td>Soupape de d\u00e9charge de sortie de tuyau de colonne montante, configuration angulaire<\/td>\n<\/tr>\n<tr>\n<td>Croker 3005 finition chrom\u00e9e apparente<\/td>\n<td><strong>UPRV-1321<\/strong><\/td>\n<td>Soupape de s\u00fbret\u00e9 chrom\u00e9e apparente pour stations de tuyaux d&#039;arrosage \u00e0 colonne montante finie<\/td>\n<\/tr>\n<tr>\n<td>Interrupteur de surveillance anti-sabotage Potter PCVS<\/td>\n<td><strong>UV-WOSY<\/strong><\/td>\n<td>Interrupteur de surveillance anti-sabotage de vanne OS&amp;Y<\/td>\n<\/tr>\n<tr>\n<td>D\u00e9tecteur de d\u00e9bit d&#039;eau Potter VSR-F<\/td>\n<td><strong>UV6001<\/strong><\/td>\n<td>D\u00e9tecteur de d\u00e9bit d&#039;eau \u00e0 palette avec retard<\/td>\n<\/tr>\n<tr>\n<td>Vanne coud\u00e9e Elkhart L-234<\/td>\n<td>Giacomini A56E (mont\u00e9 en tant qu&#039;OEM)<\/td>\n<td>Vanne coud\u00e9e pour tuyau d&#039;arrosage 2,5\u2033 NH (NST)<\/td>\n<\/tr>\n<tr>\n<td>vanne d&#039;angle \u00e0 restriction de pression Croker<\/td>\n<td>Giacomini A156 (port\u00e9 en tant qu&#039;OEM)<\/td>\n<td>Vanne coud\u00e9e de limitation de pression pour tuyau 2,5\u2033 NH<\/td>\n<\/tr>\n<tr>\n<td>Test et vidange du collecteur AGF TestManifold 1000<\/td>\n<td>Giacomini A61 (mont\u00e9 en tant que OEM)<\/td>\n<td>Vanne de test et de purge, NFPA 13 \/ 13R \/ 13D<\/td>\n<\/tr>\n<tr>\n<td>Syst\u00e8me de goutte-\u00e0-goutte automatique Potter PRV-1<\/td>\n<td><strong>UV-ABD<\/strong><\/td>\n<td>\u00c9goutte-goutte automatique \u00e0 bille pour drain FDC<\/td>\n<\/tr>\n<tr>\n<td>Croker ou Elkhart FDC 4 voies, entr\u00e9es NST 2,5\u2033<\/td>\n<td><strong>UV-FDC-EXP<\/strong> ou <strong>UV-FDC-FLASH<\/strong><\/td>\n<td>Raccordement pour pompiers (siamois), apparent ou encastr\u00e9<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2 class=\"wp-block-heading\">Bouches d&#039;incendie (AWWA C502)<\/h2>\n<p>Pour les bornes d&#039;incendie ext\u00e9rieures dans les services de protection incendie municipaux, industriels et universitaires\u00a0:<\/p>\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th>Mod\u00e8le concurrent<\/th>\n<th>\u00c9quivalent UNIVAL<\/th>\n<th>Fonction<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Canon sec Mueller A-423 Super Centurion<\/td>\n<td><strong>UV0733-250<\/strong><\/td>\n<td>Bouche d&#039;incendie \u00e0 f\u00fbt sec selon la norme AWWA C502. Deux sorties NST de 2,5 pouces plus une sortie pour pompe.<\/td>\n<\/tr>\n<tr>\n<td>Valve Kennedy K-81 canon sec<\/td>\n<td><strong>UV0733-250<\/strong><\/td>\n<td>Bouche d&#039;incendie \u00e0 f\u00fbt sec selon la norme AWWA C502.<\/td>\n<\/tr>\n<tr>\n<td>Clow Medallion f\u00fbt sec<\/td>\n<td><strong>UV0733-250<\/strong><\/td>\n<td>Bouche d&#039;incendie \u00e0 f\u00fbt sec selon la norme AWWA C502.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<p>Le filetage de sortie et le raccord d&#039;entr\u00e9e des bornes d&#039;incendie varient selon les municipalit\u00e9s. Toronto, Montr\u00e9al, New York et Boston ont chacune leurs propres sp\u00e9cifications de filetage et de couleur. Veuillez v\u00e9rifier la norme locale de filetage des bornes d&#039;incendie aupr\u00e8s de l&#039;autorit\u00e9 comp\u00e9tente avant de passer commande.<\/p>\n<h2 class=\"wp-block-heading\">Comment utiliser ce tableau pour les soumissions \u201c ou \u00e9gales \u201d<\/h2>\n<p>Les plans de protection incendie et les sp\u00e9cifications des projets mentionnent g\u00e9n\u00e9ralement un mod\u00e8le de fabricant et ajoutent la mention \u201c ou \u00e9quivalent approuv\u00e9 \u201d pour permettre une substitution lors de l&#039;approvisionnement. Lorsque l&#039;installateur ou le distributeur souhaite proposer un produit UNIVAL, la demande de substitution doit indiquer\u00a0:<\/p>\n<p>Tout d&#039;abord, la conformit\u00e9 du profil de certification est essentielle. Si le produit d&#039;origine est homologu\u00e9 UL, ULC et FM, le produit de remplacement doit satisfaire aux trois exigences. Si le produit d&#039;origine est homologu\u00e9 FM et que le produit de remplacement ne l&#039;est pas, la substitution est refus\u00e9e, m\u00eame en cas d&#039;\u00e9quivalence dimensionnelle. Les sprinklers UNIVAL UV-3 (K=5,6) sont homologu\u00e9s UL et FM. Les sprinklers encastr\u00e9s (UV820, UV821) et les sprinklers de classe K=8,0 sont uniquement homologu\u00e9s UL. Les vannes \u00e0 guillotine, les clapets papillon et les clapets anti-retour sont enti\u00e8rement certifi\u00e9s UL, ULC et FM.<\/p>\n<p>Deuxi\u00e8mement, la compatibilit\u00e9 dimensionnelle et le raccordement sont essentiels. Les raccords rainur\u00e9s doivent respecter les dimensions de rainurage de la norme AWWA C606 et accepter les tuyaux rainur\u00e9s \u00e0 coupe standard. Les vannes \u00e0 brides doivent \u00eatre conformes \u00e0 la norme ANSI B16.1, classe 125 ou 250, selon les sp\u00e9cifications. Les sprinklers filet\u00e9s sont au standard 1\/2\u2033 NPT, et certaines juridictions exigent un filetage 3\/4\u2033 NPT pour les sprinklers de classe K sup\u00e9rieure.<\/p>\n<p>Troisi\u00e8mement, la compatibilit\u00e9 de la classe de pression est essentielle. Les refoulements des pompes incendie et les colonnes montantes des immeubles de grande hauteur n\u00e9cessitent des composants de 300 ou 500 psi, et non de 175 psi. La r\u00e9f\u00e9rence des mod\u00e8les UV dans les tableaux ci-dessus indique la classe de pression \u00e0 la fin de la r\u00e9f\u00e9rence (suffixe 300 = 300 psi). Veuillez v\u00e9rifier avant toute substitution.<\/p>\n<p>Quatri\u00e8mement, compatibilit\u00e9 des garnitures et accessoires. Le remplacement des vannes d&#039;alarme n\u00e9cessite des kits de garniture, une chambre de temporisation, un avertisseur sonore pour moteur hydraulique, un pressostat de surveillance et un ensemble de conduite d&#039;\u00e9gouttement compatibles. Le remplacement des vannes \u00e0 pr\u00e9action n\u00e9cessite une \u00e9lectrovanne homologu\u00e9e avec le panneau de d\u00e9clenchement utilis\u00e9 (Notifier \/ EST \/ Potter \/ Silent Knight). Les vannes d&#039;alarme UNIVAL sont fournies avec les kits de garniture homologu\u00e9s dans un seul emballage afin de pr\u00e9server l&#039;homologation.<\/p>\n<p>Une fois ces quatre v\u00e9rifications effectu\u00e9es, le dossier de demande de substitution est transmis \u00e0 l&#039;ing\u00e9nieur prescripteur. Il comprend la fiche technique UNIVAL, les certificats de conformit\u00e9 et le dessin dimensionnel, ainsi qu&#039;un tableau comparatif d\u00e9taill\u00e9 indiquant comment la r\u00e9f\u00e9rence UNIVAL respecte ou d\u00e9passe les sp\u00e9cifications d&#039;origine. ValveAtlas pr\u00e9pare le dossier de substitution complet sur demande, dans le cadre de son service commercial et de son assistance technique.<\/p>\n<h2 class=\"wp-block-heading\">Ce que ce tableau ne couvre pas<\/h2>\n<p>Le tableau de correspondance ci-dessus concerne les vannes, les raccords, les sprinklers et les accessoires de colonnes montantes. Il ne couvre pas\u00a0:<\/p>\n<p>Les sprinklers ESFR (K=14,0, K=16,8, K=22,4, K=25,2) sont des sprinklers sp\u00e9cifiques aux b\u00e2timents occup\u00e9s, principalement commercialis\u00e9s par Tyco et Viking. UNIVAL ne propose actuellement aucune gamme ESFR\u00a0; pour les projets n\u00e9cessitant ce type de sprinklers, il est recommand\u00e9 de privil\u00e9gier le fabricant d&#039;origine.<\/p>\n<p>Les sprinklers r\u00e9sidentiels sont homologu\u00e9s UL 1626. La gamme UV-3 est homologu\u00e9e UL 199 pour les b\u00e2timents commerciaux \u00e0 risques l\u00e9gers, ordinaires et \u00e9lev\u00e9s, conform\u00e9ment \u00e0 la norme NFPA 13. Les sprinklers r\u00e9sidentiels destin\u00e9s aux applications NFPA 13R et 13D constituent une gamme de produits distincte. Voir la <a href=\"https:\/\/valve-atlas.com\/unival-vs-reliable-fire-protection\/\">Comparaison entre UNIVAL et Reliable<\/a> pour le positionnement r\u00e9sidentiel.<\/p>\n<p>Pompes incendie et syst\u00e8mes de contr\u00f4le. Les groupes motopompes incendie (\u00e9lectriques et diesel) sont r\u00e9f\u00e9renc\u00e9s s\u00e9par\u00e9ment pour les marques Patterson, Aurora, Peerless et AC Fire Pump, avec des options de contr\u00f4le propos\u00e9es par Metron, Firetrol et Tornatech. Veuillez contacter ValveAtlas pour toute demande de substitution de groupe motopompe incendie.<\/p>\n<p>Syst\u00e8mes sp\u00e9ciaux de mousse, de brouillard d&#039;eau et d&#039;agents propres. Ces syst\u00e8mes n\u00e9cessitent une ing\u00e9nierie sp\u00e9cifique et ne sont pas abord\u00e9s ici.<\/p>\n<h2 class=\"wp-block-heading\">Foire aux questions<\/h2>\n<p><strong>Une substitution \u201c ou \u00e9quivalent \u201d est-elle automatique si UNIVAL propose les m\u00eames annonces\u00a0?<\/strong> Non. \u201c\u00a0Ou \u00e9quivalent\u00a0\u201d signifie que l\u2019ing\u00e9nieur responsable de la sp\u00e9cification conserve le dernier mot. La pr\u00e9sence d\u2019homologations \u00e9quivalentes est n\u00e9cessaire, mais non suffisante. L\u2019ing\u00e9nieur examine le dossier de substitution complet (fiche technique, plan cot\u00e9, certificats d\u2019homologation, compatibilit\u00e9 des garnitures, correspondance des classes de pression, conditions de garantie) et l\u2019approuve ou le refuse. ValveAtlas pr\u00e9pare ce dossier dans le cadre de son assistance commerciale.<\/p>\n<p><strong>L\u2019autorit\u00e9 comp\u00e9tente acceptera-t-elle UNIVAL pour un projet canadien\u00a0?<\/strong> Au Canada, les codes du Code national de la construction (NBCC) et les codes provinciaux acceptent les produits homologu\u00e9s ULC pour les vannes sous pression et les raccords rainur\u00e9s utilis\u00e9s dans les syst\u00e8mes d&#039;extinction automatique \u00e0 eau. Les vannes \u00e0 guillotine, les vannes papillon, les clapets anti-retour et les raccords rainur\u00e9s UNIVAL sont homologu\u00e9s ULC. Les gicleurs UNIVAL sont homologu\u00e9s UL et reconnus en Ontario, au Qu\u00e9bec, en Colombie-Britannique et dans la plupart des autres provinces qui adoptent la norme NFPA 13 par r\u00e9f\u00e9rence. Veuillez v\u00e9rifier aupr\u00e8s de l&#039;autorit\u00e9 comp\u00e9tente locale pour chaque projet.<\/p>\n<p><strong>Quel est l&#039;impact de l&#039;approbation FM sur la substitution\u00a0?<\/strong> Les installations assur\u00e9es par FM Global n\u00e9cessitent g\u00e9n\u00e9ralement des composants homologu\u00e9s FM. Les sprinklers UNIVAL K=5.6 UV-3 sont homologu\u00e9s FM. Les vannes d&#039;alarme, les vannes \u00e0 guillotine, les vannes papillon et les clapets anti-retour UNIVAL sont homologu\u00e9s FM. Les sprinklers suspendus encastr\u00e9s UNIVAL (UV820, UV821) et les sprinklers K=8.0 ne sont pas homologu\u00e9s FM \u00e0 l&#039;heure actuelle. Les projets couverts par une assurance FM et n\u00e9cessitant des sprinklers suspendus encastr\u00e9s ou des sprinklers K=8.0 doivent respecter les sp\u00e9cifications d&#039;origine homologu\u00e9es FM.<\/p>\n<p><strong>Les raccords UNIVAL s&#039;installent-ils sur des tuyaux \u00e0 rainure standard\u00a0?<\/strong> Oui. Les mod\u00e8les UV11, UV14, UV15, UV16 et les gammes apparent\u00e9es sont rainur\u00e9s selon les dimensions de la norme AWWA C606, qui constitue la norme industrielle publi\u00e9e. Les installateurs utilisent des outils standard de rainurage par roulage ou par d\u00e9coupe sur des tubes en acier noir de type 10 ou 40, et les raccords UNIVAL s&#039;installent sans pr\u00e9paration particuli\u00e8re des tubes.<\/p>\n<p><strong>ValveAtlas fournit-il les kits de finition et les accessoires avec les vannes d&#039;alarme UNIVAL\u00a0?<\/strong> Oui. Les vannes d&#039;alarme UNIVAL sont livr\u00e9es dans un emballage individuel comprenant le kit de garniture, la chambre de temporisation, le gong \u00e0 moteur hydraulique, le pressostat de surveillance, le syst\u00e8me d&#039;amor\u00e7age et le syst\u00e8me anti-goutte. L&#039;achat simultan\u00e9 de la vanne et de la garniture garantit la conformit\u00e9 du produit et \u00e9vite \u00e0 l&#039;installateur d&#039;avoir \u00e0 assembler les pi\u00e8ces s\u00e9par\u00e9ment sur le chantier.<\/p>\n<p><strong>Qu\u2019advient-il de la garantie du fabricant lorsque UNIVAL remplace Tyco, Viking, Reliable ou Victaulic\u00a0?<\/strong> UNIVAL offre sa propre garantie constructeur, courante pour les produits de protection incendie du secteur. La garantie du produit de remplacement (UNIVAL) se substitue \u00e0 la garantie d&#039;origine. Si le cahier des charges du projet inclut une exigence de dur\u00e9e de garantie sp\u00e9cifique (par exemple, une garantie de 10 ans sur la plaque de recouvrement du luminaire suspendu dissimul\u00e9), la demande de remplacement doit mentionner la dur\u00e9e de la garantie UNIVAL et permettre \u00e0 l&#039;ing\u00e9nieur d&#039;en \u00e9valuer l&#039;impact.<\/p>\n<p><strong>Combien de temps faut-il \u00e0 ValveAtlas pour soumettre un dossier de demande de substitution\u00a0?<\/strong> Le d\u00e9lai de traitement standard est de 48 heures \u00e0 compter de la r\u00e9ception du cahier des charges et des plans. Pour les r\u00e9f\u00e9rences UNIVAL en stock, nous indiquons la disponibilit\u00e9 actuelle et le d\u00e9lai de livraison dans notre proposition. Pour les articles hors stock, nous pr\u00e9cisons le d\u00e9lai de livraison du fabricant et proposons d&#039;\u00e9ventuels mod\u00e8les UNIVAL alternatifs disponibles en stock et r\u00e9pondant aux sp\u00e9cifications.<\/p>\n<h2 class=\"wp-block-heading\">Pages de r\u00e9f\u00e9rence crois\u00e9e connexes<\/h2>\n<p>Pour une comparaison produit par produit avec plus de contexte sur la gamme de produits de chaque concurrent, voir\u00a0:<\/p>\n<p><a href=\"https:\/\/valve-atlas.com\/unival-vs-victaulic-grooved-valves\/\">UNIVAL contre Victaulic\u00a0: raccords et vannes rainur\u00e9s<\/a> couvre en d\u00e9tail la substitution de couplage avec l&#039;angle d&#039;acceptation ULC de Toronto.<\/p>\n<p><a href=\"https:\/\/valve-atlas.com\/unival-vs-tyco-fire-sprinklers\/\">Comparaison des extincteurs automatiques UNIVAL et Tyco<\/a> couvre les gammes de produits Tyco (Johnson Controls) et les anciennes marques Central \/ Star \/ Gem.<\/p>\n<p><a href=\"https:\/\/valve-atlas.com\/unival-vs-viking-fire-protection\/\">Protection incendie UNIVAL contre Viking<\/a> couvre les vannes d&#039;alarme Viking, les syst\u00e8mes de pr\u00e9action et le positionnement ESFR.<\/p>\n<p><a href=\"https:\/\/valve-atlas.com\/unival-vs-reliable-fire-protection\/\">Protection incendie UNIVAL vs Reliable<\/a> couvre le positionnement des suspensions dissimul\u00e9es et des sprinklers r\u00e9sidentiels dans le contexte de la norme UL 1626.<\/p>\n<p>Pour consulter le catalogue complet des arroseurs UNIVAL, veuillez vous r\u00e9f\u00e9rer au <a href=\"https:\/\/valve-atlas.com\/fire-sprinklers\/\">page de cat\u00e9gorie des extincteurs automatiques<\/a> avec la gamme compl\u00e8te de produits UV-3.<\/p>\n<h2 class=\"wp-block-heading\">Contactez ValveAtlas pour obtenir un kit de remplacement<\/h2>\n<p>Pour obtenir un dossier de substitution \u201c\u00a0ou \u00e9quivalent\u00a0\u201d pour un projet en cours, veuillez envoyer les sp\u00e9cifications et les plans du projet \u00e0 burakpadr@gmail.com ou utiliser le formulaire de contact de notre site web. Nous vous fournirons un dossier complet de substitution, d\u00e9taillant la conformit\u00e9 aux sp\u00e9cifications ligne par ligne, la s\u00e9lection des r\u00e9f\u00e9rences UNIVAL, les homologations (UL\/ULC\/FM), la confirmation de stock et le prix, sous un jour ouvr\u00e9 pour les articles en stock et sous 48\u00a0heures pour les articles hors stock ou les configurations sp\u00e9ciales.<\/p>\n<p>Pour obtenir des informations sur les \u00e9quipements de protection incendie sp\u00e9cifiques \u00e0 chaque ville (Toronto, Montr\u00e9al, New York, Boston), consultez nos pages r\u00e9gionales\u00a0: <a href=\"https:\/\/valve-atlas.com\/fire-protection-toronto\/\">Toronto<\/a>, <a href=\"https:\/\/valve-atlas.com\/fire-protection-montreal\/\">Montr\u00e9al<\/a>, <a href=\"https:\/\/valve-atlas.com\/fire-protection-new-york\/\">New York<\/a>, <a href=\"https:\/\/valve-atlas.com\/fire-protection-boston\/\">Boston<\/a>.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Map UNIVAL UV-series SKUs to Tyco, Viking, Reliable and Victaulic model numbers for or-equal fire protection substitution requests.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"content-type":"","iawp_total_views":0,"footnotes":""},"class_list":["post-41640","page","type-page","status-publish","hentry","description-off"],"acf":[],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41640","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=41640"}],"version-history":[{"count":4,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41640\/revisions"}],"predecessor-version":[{"id":42547,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41640\/revisions\/42547"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=41640"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}