{"id":41061,"date":"2025-11-05T03:52:30","date_gmt":"2025-11-05T03:52:30","guid":{"rendered":"https:\/\/valve-atlas.com\/?page_id=41061"},"modified":"2026-06-05T11:09:08","modified_gmt":"2026-06-05T11:09:08","slug":"fire-pumpsboosters","status":"publish","type":"page","link":"https:\/\/valve-atlas.com\/fr_ca\/fire-pumpsboosters\/","title":{"rendered":"Pompes \u00e0 incendie et surpresseurs"},"content":{"rendered":"\n<style>\n.va-rac-wrap{max-width:1200px;margin:0 auto;padding:24px 32px}\n@media(max-width:768px){.va-rac-wrap{padding:16px}}\n.va-rac-hero{display:grid;grid-template-columns:1.1fr 1fr;gap:32px;align-items:center;padding:40px 0;border-bottom:1px solid #e5e7eb;margin-bottom:32px}\n.va-rac-brand-row{display:flex;align-items:center;gap:18px;margin-bottom:18px;flex-wrap:wrap}\n.va-rac-brand-row .brand-block{display:flex;align-items:center;gap:12px}\n.va-rac-brand-row img{width:72px;height:auto}\n.va-rac-brand-row .brand-text{display:flex;flex-direction:column}\n.va-rac-brand-row .brand-text strong{font-size:18px;letter-spacing:.5px;color:#0a1f3a}\n.va-rac-brand-row .brand-text small{color:#5a6b85;font-size:12px}\n.va-hero-logo{background:#f8fafb;padding:30px;border-radius:8px;display:flex;align-items:center;justify-content:center;min-height:240px}\n.va-hero-logo img{max-width:100%;max-height:200px;width:auto;object-fit:contain}\n.va-rac-section{margin:40px 0}\n.va-rac-section h2{color:#0a1f3a;font-size:24px;margin:0 0 8px}\n.va-rac-section .lead{color:#5a6b85;font-size:14px;margin-bottom:20px}\n.va-cert-card{background:#fff;border:2px solid #065f46;border-radius:10px;padding:20px;margin:20px 0;display:grid;grid-template-columns:auto 1fr;gap:18px;align-items:center}\n.va-cert-card .cert-badge{background:#065f46;color:#fff;border-radius:50%;width:60px;height:60px;display:flex;align-items:center;justify-content:center;font-weight:700;font-size:13px;text-align:center;line-height:1.1}\n.va-cert-card .cert-info strong{display:block;color:#0a1f3a;font-size:15px;margin-bottom:2px}\n.va-cert-card .cert-info small{color:#5a6b85;font-size:12px;line-height:1.5;display:block}\n.va-table-section{margin:24px 0}\n.va-table-section h3{color:#0a1f3a;font-size:18px;margin:0 0 4px;display:flex;align-items:center;gap:10px;flex-wrap:wrap}\n.va-table-section h3 .approval{background:#ecfdf5;color:#065f46;font-size:11px;font-weight:700;padding:3px 10px;border-radius:4px;letter-spacing:.5px}\n.va-table-section .desc{color:#5a6b85;font-size:13px;margin:0 0 12px;line-height:1.5}\n.va-pump-table{width:100%;border-collapse:collapse;font-size:13px;background:#fff;border:1px solid #e5e7eb;border-radius:8px;overflow:hidden}\n.va-pump-table th{background:#0a1f3a;color:#fff;text-align:left;padding:10px 12px;font-weight:600;font-size:12px;letter-spacing:.3px}\n.va-pump-table td{padding:9px 12px;border-top:1px solid #f0f2f6;color:#37415a}\n.va-pump-table tr:nth-child(even){background:#fafbfc}\n.va-pump-table .model{font-weight:600;color:#0a1f3a}\n.va-scope-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(220px,1fr));gap:14px;margin:20px 0}\n.va-scope-item{background:#f8fafb;padding:16px;border-radius:8px;border-left:3px solid #0a1f3a}\n.va-scope-item strong{display:block;color:#0a1f3a;font-size:14px;margin-bottom:4px}\n.va-scope-item small{color:#5a6b85;font-size:12px;line-height:1.5}\n.va-spec-row{display:grid;grid-template-columns:repeat(auto-fit,minmax(160px,1fr));gap:10px;margin:14px 0;background:#fafbfc;padding:14px;border-radius:8px}\n.va-spec-row .item strong{display:block;font-size:11px;color:#5a6b85;text-transform:uppercase;letter-spacing:.5px;margin-bottom:2px}\n.va-spec-row .item span{color:#0a1f3a;font-weight:600;font-size:14px}\n.va-rac-usecases{display:grid;grid-template-columns:repeat(auto-fit,minmax(200px,1fr));gap:14px;margin:20px 0}\n.va-rac-usecase{background:#f8fafb;padding:18px;border-radius:8px}\n.va-rac-usecase strong{display:block;color:#0a1f3a;margin-bottom:4px;font-size:14px}\n.va-rac-usecase small{color:#5a6b85;font-size:13px;line-height:1.5}\n.va-rac-cta{background:#0a1f3a;color:#fff;padding:36px;border-radius:12px;text-align:center;margin:40px 0}\n.va-rac-cta h2{margin:0 0 12px;color:#fff;font-size:24px}\n.va-rac-cta p{margin:0 0 22px;color:#cfd6e2}\n.va-rac-cta a{display:inline-block;background:#fff;color:#0a1f3a;padding:14px 36px;border-radius:6px;text-decoration:none;font-weight:600;font-size:15px}\n.va-rac-cta a:hover{background:#f1f4f9}\n.va-rac-region{font-size:13px;color:#5a6b85;margin-top:16px}\n.va-cert-strip{display:flex;flex-wrap:wrap;gap:8px;margin:12px 0 0}\n.va-cert-strip span{background:#f0f9ff;color:#075985;font-size:11px;font-weight:600;padding:4px 10px;border-radius:3px;border:1px solid #bae6fd}\n<\/style>\n\n<div class=\"va-rac-wrap\">\n\n<section class=\"va-rac-hero\">\n<div>\n  <div class=\"va-rac-brand-row\">\n    <div class=\"brand-block\">\n      <img decoding=\"async\" data-src=\"https:\/\/valve-atlas.com\/wp-content\/uploads\/2025\/12\/Screenshot-2025-12-21-192406.png\" alt=\"ETNA Pumps\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" style=\"--smush-placeholder-width: 293px; --smush-placeholder-aspect-ratio: 293\/122;\">\n      <div class=\"brand-text\"><strong>ETNA<\/strong><small>UL Listed &amp; FM Approved UF Series<\/small><\/div>\n    <\/div>\n  <\/div>\n  <h2 style=\"margin:0 0 14px;color:#0a1f3a;font-size:28px;line-height:1.25\">Fire Pumps &amp; Boosters<\/h2>\n  <p style=\"color:#37415a;font-size:15px;line-height:1.65;margin:0\"><strong>ETNA UF Series<\/strong> \u2014 UL Listed (UL 448) and FM Approved (FM 1319) fire pump packages compliant with <strong>NFPA 20<\/strong> and <strong>EN 12845<\/strong>. End-suction <strong>EA series<\/strong> (250\u20131,000 GPM, UL + FM) and split-case <strong>ESC series<\/strong> (500\u20132,000 GPM, UL Listed) delivered as complete sets with pump, UL\/FM listed diesel engine or electric motor, UL\/FM approved control panel, jockey pump and system accessories. 46+ years of pump-engineering experience.<\/p>\n  <div class=\"va-cert-strip\">\n    <span>UL Listed<\/span><span>FM Approved<\/span><span>UL 448<\/span><span>FM 1319<\/span><span>NFPA 20<\/span><span>EN 12845<\/span>\n  <\/div>\n  <div class=\"va-rac-region\">Toronto-based \u00b7 Canada \u00b7 US Northeast (NYC, Boston) \u00b7 London UK<\/div>\n<\/div>\n<div class=\"va-hero-logo\">\n  <img decoding=\"async\" data-src=\"https:\/\/valve-atlas.com\/wp-content\/uploads\/2025\/12\/Screenshot-2025-12-21-192406.png\" alt=\"ETNA UF Series UL Listed and FM Approved fire pump package \u2014 pump, UL\/FM listed diesel\/electric motor, control panel, jockey pump\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" class=\"lazyload\" style=\"--smush-placeholder-width: 293px; --smush-placeholder-aspect-ratio: 293\/122;\">\n<\/div>\n<\/section>\n\n<div class=\"va-cert-card\">\n  <div class=\"cert-badge\">FM<br>1319<\/div>\n  <div class=\"cert-info\">\n    <strong>FM Approval \u2014 Certificate of Compliance PR468288<\/strong>\n    <small>Centrifugal Fire Pumps (Horizontal, End Suction Type) \u00b7 Approval Class 1319 \u00b7 Granted 12 June 2024 \u00b7 Manufactured by ALP Pompa Teknolojileri A.\u015e. (ETNA&#8217;s pump arm, \u00dcmraniye, Istanbul, Turkey) \u00b7 Listed at www.approvalguide.com<\/small>\n  <\/div>\n<\/div>\n\n<section class=\"va-rac-section\">\n<h2>ETNA UF Series \u2014 End-Suction &amp; Split-Case Fire Pumps<\/h2>\n<p class=\"lead\">UF Series pumps are delivered as complete factory-assembled sets including driver (diesel or electric), control panel, pilot\/jockey pump, and standard fire-pump system accessories. Pump performance verified per UL 448 and FM 1319 test conditions. Main pump dimensions per DIN 24256; flanges per ISO 7005 PN16 (ANSI\/ASME B16.1 Class 300 optional).<\/p>\n\n<div class=\"va-table-section\">\n<h3>EA Series \u2014 End-Suction Fire Pumps <span class=\"approval\">UL Listed &amp; FM Approved<\/span><\/h3>\n<p class=\"desc\">Single-stage, end-suction centrifugal pumps with enclosed impeller (Bronze CuSn10). Suction-discharge flange sizing per DIN. Maximum working pressure to 290 psi (20 bar) on EA 80-32 and EA 100-32 variants.<\/p>\n<table class=\"va-pump-table\">\n<thead><tr><th>Model<\/th><th>Rated Capacity<\/th><th>Size (Suction \u2013 Discharge)<\/th><th>Net Rated Pressure<\/th><th>Speed<\/th><th>Max Working Pressure<\/th><\/tr><\/thead>\n<tbody>\n<tr><td class=\"model\">EA 65-26<\/td><td>250 GPM<\/td><td>DN80 \u2013 DN65<\/td><td>94\u2013133 psi (6.5\u20139.2 bar)<\/td><td>2,950 RPM<\/td><td>166 psi (11.5 bar)<\/td><\/tr>\n<tr><td class=\"model\">EA 65-26<\/td><td>300 GPM<\/td><td>DN80 \u2013 DN65<\/td><td>93\u2013131 psi (6.5\u20139.2 bar)<\/td><td>2,950 RPM<\/td><td>166 psi (11.5 bar)<\/td><\/tr>\n<tr><td class=\"model\">EA 65-26<\/td><td>400 GPM<\/td><td>DN80 \u2013 DN65<\/td><td>90\u2013128 psi (6.2\u20138.8 bar)<\/td><td>2,950 RPM<\/td><td>166 psi (11.5 bar)<\/td><\/tr>\n<tr><td class=\"model\">EA 65-26<\/td><td>500 GPM<\/td><td>DN80 \u2013 DN65<\/td><td>84\u2013123 psi (5.8\u20138.5 bar)<\/td><td>2,950 RPM<\/td><td>166 psi (11.5 bar)<\/td><\/tr>\n<tr><td class=\"model\">EA 80-32<\/td><td>500 GPM<\/td><td>DN100 \u2013 DN80<\/td><td>127\u2013196 psi (8.8\u201313.5 bar)<\/td><td>2,950 RPM<\/td><td>290 psi (20 bar)<\/td><\/tr>\n<tr><td class=\"model\">EA 100-32<\/td><td>750 GPM<\/td><td>DN125 \u2013 DN100<\/td><td>115\u2013174 psi (7.9\u201312 bar)<\/td><td>2,950 RPM<\/td><td>290 psi (20 bar)<\/td><\/tr>\n<tr><td class=\"model\">EA 100-32<\/td><td>1,000 GPM<\/td><td>DN125 \u2013 DN100<\/td><td>149\u2013169 psi (10.2\u201311.6 bar)<\/td><td>2,950 RPM<\/td><td>290 psi (20 bar)<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<div class=\"va-table-section\">\n<h3>ESC Series \u2014 Horizontal Split-Case Fire Pumps <span class=\"approval\">UL Listed<\/span><\/h3>\n<p class=\"desc\">Double-suction horizontal split-case configuration for high-flow applications. Maximum working pressure up to 400 psi (27.6 bar) on ESC 100-375 variant.<\/p>\n<table class=\"va-pump-table\">\n<thead><tr><th>Model<\/th><th>Rated Capacity<\/th><th>Size (Suction \u2013 Discharge)<\/th><th>Net Rated Pressure<\/th><th>Speed<\/th><th>Max Working Pressure<\/th><\/tr><\/thead>\n<tbody>\n<tr><td class=\"model\">ESC 100-250<\/td><td>500 GPM<\/td><td>DN150 \u2013 DN100<\/td><td>80\u2013140 psi (5.5\u20139.7 bar)<\/td><td>2,900 RPM<\/td><td>232 psi (16 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 100-310<\/td><td>500 GPM<\/td><td>DN150 \u2013 DN100<\/td><td>130\u2013204 psi (9\u201314 bar)<\/td><td>2,900 RPM<\/td><td>290 psi (20 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 100-375<\/td><td>500 GPM<\/td><td>DN150 \u2013 DN100<\/td><td>215\u2013300 psi (15\u201321 bar)<\/td><td>2,900 RPM<\/td><td>400 psi (27.6 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 100-250<\/td><td>750 GPM<\/td><td>DN150 \u2013 DN100<\/td><td>73\u2013139 psi (5\u20139.6 bar)<\/td><td>2,900 RPM<\/td><td>232 psi (16 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 100-310<\/td><td>750 GPM<\/td><td>DN150 \u2013 DN100<\/td><td>125\u2013198 psi (8.6\u201313.7 bar)<\/td><td>2,900 RPM<\/td><td>290 psi (20 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 100-375<\/td><td>750 GPM<\/td><td>DN150 \u2013 DN100<\/td><td>199\u2013280 psi (13.7\u201319.3 bar)<\/td><td>2,900 RPM<\/td><td>400 psi (27.6 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 125-290<\/td><td>1,000 GPM<\/td><td>DN200 \u2013 DN125<\/td><td>101\u2013177 psi (7\u201312.2 bar)<\/td><td>2,900 RPM<\/td><td>232 psi (16 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 125-365<\/td><td>1,000 GPM<\/td><td>DN200 \u2013 DN125<\/td><td>178\u2013288 psi (12.2\u201319.9 bar)<\/td><td>2,900 RPM<\/td><td>348 psi (24 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 125-290<\/td><td>1,250 GPM<\/td><td>DN200 \u2013 DN125<\/td><td>97\u2013175 psi (6.7\u201312 bar)<\/td><td>2,900 RPM<\/td><td>232 psi (16 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 125-365<\/td><td>1,250 GPM<\/td><td>DN200 \u2013 DN125<\/td><td>161\u2013278 psi (11.4\u201319.2 bar)<\/td><td>2,900 RPM<\/td><td>348 psi (24 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 150-290<\/td><td>1,500 GPM<\/td><td>DN250 \u2013 DN150<\/td><td>98\u2013155 psi (6.8\u201310.7 bar)<\/td><td>2,900 RPM<\/td><td>232 psi (16 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 150-360<\/td><td>1,500 GPM<\/td><td>DN250 \u2013 DN150<\/td><td>150\u2013242 psi (10.4\u201316.7 bar)<\/td><td>2,900 RPM<\/td><td>320 psi (22.1 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 150-290<\/td><td>2,000 GPM<\/td><td>DN250 \u2013 DN150<\/td><td>94\u2013149 psi (6.5\u201310.3 bar)<\/td><td>2,900 RPM<\/td><td>232 psi (16 bar)<\/td><\/tr>\n<tr><td class=\"model\">ESC 150-360<\/td><td>2,000 GPM<\/td><td>DN250 \u2013 DN150<\/td><td>138\u2013234 psi (9.5\u201316.2 bar)<\/td><td>2,900 RPM<\/td><td>320 psi (22.1 bar)<\/td><\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/section>\n\n<section class=\"va-rac-section\">\n<h2>Scope of Delivery \u2014 Complete UF Series Set<\/h2>\n<p class=\"lead\">Every ETNA UF Series fire pump ships as a complete factory-assembled set ready for site installation.<\/p>\n<div class=\"va-scope-grid\">\n<div class=\"va-scope-item\"><strong>Fire Pump<\/strong><small>EA end-suction or ESC split-case body, sized per project hydraulic calc.<\/small><\/div>\n<div class=\"va-scope-item\"><strong>UL\/FM Listed Diesel Engine<\/strong><small>For redundant power supply or sites without reliable electrical service.<\/small><\/div>\n<div class=\"va-scope-item\"><strong>Electric Motor<\/strong><small>IEC standard motor with UL listed option available.<\/small><\/div>\n<div class=\"va-scope-item\"><strong>UL\/FM Approved Control Panel<\/strong><small>Electrical (full or reduced voltage) or GDP diesel panel \u2014 NEMA 2 rated.<\/small><\/div>\n<div class=\"va-scope-item\"><strong>Jockey (Pilot) Pump<\/strong><small>Pressure-maintenance pump prevents main-pump short-cycling per NFPA 20 \u00a76.6.1.<\/small><\/div>\n<div class=\"va-scope-item\"><strong>UL\/FM Accessories<\/strong><small>Air release valve \u00b7 main relief valve \u00b7 casing relief valve \u00b7 flow meter (optional).<\/small><\/div>\n<\/div>\n<\/section>\n\n<section class=\"va-rac-section\">\n<h2>Construction &amp; Materials<\/h2>\n<div class=\"va-spec-row\">\n<div class=\"item\"><strong>Pump Body<\/strong><span>GGG40 ductile iron<\/span><\/div>\n<div class=\"item\"><strong>Impeller<\/strong><span>Bronze CuSn10<\/span><\/div>\n<div class=\"item\"><strong>Shaft<\/strong><span>AISI 420 stainless<\/span><\/div>\n<div class=\"item\"><strong>Sealing<\/strong><span>Gland packing<\/span><\/div>\n<div class=\"item\"><strong>Bearing<\/strong><span>Greased, closed type<\/span><\/div>\n<div class=\"item\"><strong>Flanges<\/strong><span>ISO 7005 PN16 (or ANSI Class 300)<\/span><\/div>\n<\/div>\n<p style=\"font-size:13px;color:#5a6b85\">Bronze or corrosion-resistant materials used for all wetted elements (bolts, screws) in contact with water inside the pump. Single-suction enclosed impeller is statically balanced against axial load with wear rings and dynamically balanced with bearings.<\/p>\n<\/section>\n\n<section class=\"va-rac-section\">\n<h2>Control Panels<\/h2>\n<p class=\"lead\">UL\/FM approved electrical and diesel-engine control panels, NEMA 2 rated, microprocessor-controlled.<\/p>\n<div class=\"va-scope-grid\">\n<div class=\"va-scope-item\">\n<strong>Electrical Control Panel<\/strong>\n<small>Microprocessor-controlled \u00b7 single operator for isolating switch &amp; circuit breaker \u00b7 voltage\/current display \u00b7 surge arrester \u00b7 pressure &amp; event recorder \u00b7 test start button \u00b7 auto-transfer compatible \u00b7 emergency start handle \u00b7 locked-rotor &amp; phase-reversal protection \u00b7 full or reduced voltage starting \u00b7 audible alarm + remote contacts.<\/small>\n<\/div>\n<div class=\"va-scope-item\">\n<strong>GDP Diesel Control Panel<\/strong>\n<small>Microprocessor-controlled \u00b7 battery voltage\/current display \u00b7 pressure &amp; event recorder \u00b7 manual start buttons \u00b7 pressure transducers + run-test solenoid externally mounted \u00b7 weekly test timer \u00b7 adjustable auto shut-off \u00b7 sequential filling &amp; programmable start delay timers \u00b7 audible alarm + remote contacts.<\/small>\n<\/div>\n<\/div>\n<\/section>\n\n<section class=\"va-rac-section\">\n<h2>Typical Applications<\/h2>\n<div class=\"va-rac-usecases\">\n<div class=\"va-rac-usecase\"><strong>Sprinkler Systems<\/strong><small>NFPA 13 wet, dry, pre-action and deluge with NFPA 20 fire pump supply.<\/small><\/div>\n<div class=\"va-rac-usecase\"><strong>Hydrant &amp; Standpipe<\/strong><small>NFPA 14 standpipe risers and outdoor hydrant loops for commercial &amp; industrial.<\/small><\/div>\n<div class=\"va-rac-usecase\"><strong>Foam Extinguishing<\/strong><small>Monitor nozzles &amp; foam-generator systems for petrochemical, hangar, tank-farm protection.<\/small><\/div>\n<div class=\"va-rac-usecase\"><strong>Commercial High-Rise<\/strong><small>Class I\/II\/III standpipe supply with diesel + electric redundancy.<\/small><\/div>\n<div class=\"va-rac-usecase\"><strong>Industrial &amp; Hospital<\/strong><small>NFPA 99\/101 facilities \u2014 UL\/FM listed package with FM 1319 certification (PR468288).<\/small><\/div>\n<div class=\"va-rac-usecase\"><strong>Airport, Hotel, Mall<\/strong><small>Large-occupancy structures requiring redundant pump packages with controllers.<\/small><\/div>\n<\/div>\n<\/section>\n\n<section class=\"va-rac-section\">\n<h2>Pump Performance Conditions (UL \/ FM Requirements)<\/h2>\n<div class=\"va-spec-row\">\n<div class=\"item\"><strong>Flow at 150% Rated<\/strong><span>\u2265 65% of rated pressure<\/span><\/div>\n<div class=\"item\"><strong>Closed-Valve Pressure<\/strong><span>\u2264 140% of rated pressure<\/span><\/div>\n<div class=\"item\"><strong>Motor Power<\/strong><span>\u2265 Required at 150% flow<\/span><\/div>\n<\/div>\n<p style=\"font-size:13px;color:#5a6b85\">UL Listed and FM Approved pumps must meet these performance envelopes throughout the operating range, verified during pump performance testing per UL 448 and FM 1319.<\/p>\n<\/section>\n\n<div class=\"va-rac-cta\">\n<h2>Request a Quote \u2014 ETNA UF Series Fire Pump<\/h2>\n<p>Send your hydraulic calculation (GPM, PSI), site service requirements (electric \/ diesel \/ both for redundancy), and authority requirements (UL \/ FM \/ local AHJ). We respond within 24 hours with a complete package quote including listed pump, motor\/engine, control panel, jockey pump and accessories.<\/p>\n<a href=\"https:\/\/valve-atlas.com\/contact\/\">Request a Quote \u2192<\/a>\n<\/div>\n\n<\/div>\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@graph\": [\n    {\n      \"@type\": \"WebPage\",\n      \"@id\": \"https:\/\/valve-atlas.com\/fire-pumpsboosters\/\",\n      \"name\": \"Fire Pumps & Boosters \u2014 ETNA UF Series UL Listed & FM Approved\",\n      \"description\": \"ETNA UF Series UL Listed (UL 448) and FM Approved (FM 1319, Certificate PR468288) fire pump packages compliant with NFPA 20 and EN 12845. EA end-suction (250\u20131,000 GPM) and ESC split-case (500\u20132,000 GPM) configurations. Complete sets with UL\/FM listed motor, control panel, jockey pump, and accessories. Toronto-based supplier serving Canada, US Northeast, and London UK.\"\n    },\n    {\n      \"@type\": \"BreadcrumbList\",\n      \"itemListElement\": [\n        {\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/valve-atlas.com\/\"},\n        {\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/valve-atlas.com\/products-catalog\/\"},\n        {\"@type\":\"ListItem\",\"position\":3,\"name\":\"Fire Pumps & Boosters\",\"item\":\"https:\/\/valve-atlas.com\/fire-pumpsboosters\/\"}\n      ]\n    },\n    {\n      \"@type\": \"Product\",\n      \"name\": \"ETNA UF Series Fire Pump Package\",\n      \"description\": \"UL Listed (UL 448) and FM Approved (FM 1319, Certificate PR468288) NFPA 20 fire pump package. EA Series end-suction 250\u20131,000 GPM (max 290 psi MWP) and ESC Series split-case 500\u20132,000 GPM (max 400 psi MWP). Complete factory-assembled set: pump (GGG40 body, Bronze CuSn10 impeller, AISI 420 shaft) + UL\/FM listed diesel engine or UL listed electric motor + UL\/FM approved control panel (NEMA 2) + jockey pump + air release\/relief\/casing valves. Manufactured by ALP Pompa Teknolojileri A.\u015e. (\u00dcmraniye, Istanbul, Turkey).\",\n      \"brand\": {\"@type\":\"Brand\",\"name\":\"ETNA\"},\n      \"manufacturer\": {\"@type\":\"Organization\",\"name\":\"ALP Pompa Teknolojileri A.\u015e.\"},\n      \"category\": \"Fire Pumps\",\n      \"keywords\": \"ETNA UF Series, ETNA fire pump, UL Listed fire pump, FM Approved fire pump, NFPA 20 fire pump, end suction fire pump, split case fire pump, EA 65-26, EA 80-32, EA 100-32, ESC 100-250, ESC 125-290, ESC 150-360, FM 1319, UL 448, jockey pump, fire pump controller, Toronto fire pump supplier, Canada, USA, UK\",\n      \"hasCertification\": [\n        {\"@type\":\"Certification\",\"name\":\"UL Listed (UL 448)\",\"issuedBy\":{\"@type\":\"Organization\",\"name\":\"Underwriters Laboratories\"}},\n        {\"@type\":\"Certification\",\"name\":\"FM Approved (FM 1319, Certificate PR468288)\",\"issuedBy\":{\"@type\":\"Organization\",\"name\":\"FM Approvals\"},\"validFrom\":\"2024-06-12\"}\n      ],\n      \"offers\": {\n        \"@type\": \"AggregateOffer\",\"offerCount\":99,\"lowPrice\":\"1\",\"highPrice\":\"99999\",\n        \"priceCurrency\": \"CAD\",\n        \"availability\": \"https:\/\/schema.org\/InStock\",\n        \"areaServed\": [\"Canada\",\"United States\",\"United Kingdom\"]\n      }\n    },\n    {\n      \"@type\": \"Service\",\n      \"serviceType\": \"NFPA 20 fire pump package supply with UL\/FM listed pump, motor, controller, jockey pump and accessories\",\n      \"provider\": {\"@type\":\"Organization\",\"name\":\"ValveAtlas Industrial Solutions Inc.\"},\n      \"areaServed\": [\"Toronto\",\"Montreal\",\"New York\",\"Boston\",\"London\"]\n    }\n  ]\n}\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>UL\/FM listed ETNA fire pumps and water booster systems \u2014 EN 12845 &#038; NFPA 20 certified. Diesel, electric, jockey pumps with control panels. Toronto-based supplier with installation support across Canada, US, UK.<\/p>","protected":false},"author":1,"featured_media":43420,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"content-type":"","iawp_total_views":23,"footnotes":""},"class_list":["post-41061","page","type-page","status-publish","has-post-thumbnail","hentry","description-off"],"acf":[],"_links":{"self":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/comments?post=41061"}],"version-history":[{"count":27,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41061\/revisions"}],"predecessor-version":[{"id":44008,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/pages\/41061\/revisions\/44008"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media\/43420"}],"wp:attachment":[{"href":"https:\/\/valve-atlas.com\/fr_ca\/wp-json\/wp\/v2\/media?parent=41061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}